Sürdürülebilir Kalkınma Amaçları
Yayınlar
- MakaleAçık Erişim2016Scopus SJRQ1A novel roof type heat recovery panel for low-carbon buildings: An experimental investigation
Cuce, Pinar Mert; Cuce, Erdem; Riffat, Saffa
Energy saving and its efficient utilization is of prime interest in today's world due to the limited energy resources and growing significance of environmental issues. Despite the intensive efforts to narrow the gap between conventional energy sources (wood, coal, gas, oil, etc.) and renewables, renewable energy resources currently supply only about 14% of total world energy demand. In this regard, energy management and optimization are considered compulsory as much as the clean energy generation. Recent works indicate that the buildings play a significant role on global energy consumption. They are responsible for about 40% of global energy demand. Among the different building types, domestic buildings have the largest share with 63% and most of energy is utilized for heating, ventilation and air conditioning (HVAC) systems in those buildings. Energy consumption levels of buildings can be notably reduced through waste heat recovery in HVAC systems. There are several attempts in literature addressing the possibility of decreasing energy consumption of buildings via waste heat recovery technologies. The heat recovery technologies are cost effective and user friendly applications. The use of heat recovery systems aims at mitigating the energy consumption for HVAC applications as well as the greenhouse gas emissions, and hence decreasing the adverse effects of global warming on the Earth. It is well-documented in literature that the heat recovery systems are very promising for domestic applications. In this paper, experimental results of a novel heat recovery system developed for low-carbon buildings are presented. The proposed heat recovery system consists of a plate-type heat exchanger, blower fans and ducts. The parallel-flow arrangement is used to run the system. The system is designed as under roof application. The aim of the system is to recover waste heat and to preheat fresh air using stale air. The experiments of the system are carried out in winter season in Kent, UK. The study aims to investigate the coefficient of performance (COP) of the system as well as the heat recovery efficiency. The results show that the heat recovery efficiency of the proposed system is around 89% while the COP is 4.5. The proposed system can be used in both winter and summer conditions without requiring additional work. Its labor cost is extremely low, so it is cost-effective and user friendly.
AtıfScopus28WoS23OpenAlex31İncele
- MakaleAçık Erişim2016Scopus SJRQ1Novel glazing technologies to mitigate energy consumption in low-carbon buildings: A comparative experimental investigation
Cuce, Erdem; Cuce, Pinar Mert; Riffat, Saffa
Buildings play a key role in total world energy consumption as a consequence of poor thermal insulation characteristics of facade materials. Among the elements of a typical building envelope, windows are responsible for the greatest energy loss because of their notably high overall heat transfer coefficients. About 60% of heat loss through the building fabric can be attributed to the glazed areas. In this respect, novel cost-effective glazing technologies are needed to mitigate energy consumption, and thus to achieve the latest targets toward low/zero carbon buildings. Therefore in this study, three unique glazing products called vacuum tube window, heat insulation solar glass and solar pond window which have recently been developed at the University of Nottingham are introduced, and thermal performance analysis of each glazing technology is done through a comparative experimental investigation for the first time in literature. Standardized co-heating test methodology is performed, and overall heat transfer coefficient (U-value) is determined for each glazing product following the tests carried out in a calibrated environmental chamber. The research essentially aims at developing cost-effective solutions to mitigate energy consumption because of windows. The results indicate that each glazing technology provides very promising U-values which are incomparable with conventional commercial glazing products. Among the samples tested, the lowest U-value is obtained from the vacuum tube window by 0.40W/m2K, which corresponds to five times better thermal insulation ability compared to standard air filled double glazed windows.
AtıfScopus35WoS33OpenAlex37İncele
- Derleme MakaleYalnız künye2016Scopus SJRQ1Vacuum glazing for highly insulating windows: Recent developments and future prospects
Cuce, Erdem; Cuce, Pinar Mert
A comprehensive review of vacuum glazing technology from state-of-the-art developments to future prospects has been presented. The review has been conducted in a thematic way in order to allow an easier comparison, discussion and evaluation of the findings. First, a thorough overview of historical development of vacuum glazing has been given. Then, numerous experimental, theoretical, numerical and simulation works on the scope have been evaluated and the characteristic results from the said works have been analyzed. Commercial vacuum glazing products in market have been assessed in terms of several performance parameters such as overall heat transfer coefficient, visible light transmittance, solar heat gain coefficient and cost. Techno-economic and environmental aspects of vacuum glazing technology have also been discussed. It can be concluded from the results that overall heat transfer coefficient of a vacuum glazing can be reduced up to 0.20 W/m2K through optimized integrations with low-e coatings. The incomparable U-value range of vacuum glazing enables significant mitigation in energy consumption levels and greenhouse gas emissions. Retrofitting 25.6 million homes in the UK with vacuum glazing can provide a carbon abatement of about 40 million tonnes a year, which is very promising.
AtıfScopus138WoS117OpenAlex148İncele
- MakaleYalnız künye2016Scopus SJRQ1Energy saving potential of heat insulation solar glass: Key results from laboratory and in-situ testing
Cuce, Erdem; Cuce, Pinar Mert; Young, Chin-Huai
HISG (heat insulation solar glass) is a recently developed multi-functional glazing technology to mitigate energy consumption of buildings. HISG can generate electricity similar to conventional PV (photovoltaic) glazing products when exposed to sunlight, however it differs from them by having some extraordinary characteristic features such as thermal insulation, which is competitive with Argon filled triple glazed windows, acoustic comfort, remarkable energy saving potential and self-cleaning ability owing to TiO2 nano coating. Within the scope of this research, latest results from laboratory and in-situ testing of HISG are presented in terms of its key role in mitigating heating and cooling demand of buildings as well as clean energy generation. Lighting and thermal comfort related parameters such as shading coefficient, UV, IR and visible light intensity are also investigated through the tests conducted in real operating conditions. It is achieved from the results that instant electricity generation of HISG is 16% higher than that of standard PV glazing owing to its nano layer reflective film. Shading coefficient of HISG is only 0.136, which provides almost 80% reduction in solar heat gain compared to ordinary glazing. Indoor air temperature measured from HISG test house in summer time is very close to the ambient temperature, whereas it is found to be 14.7 °C higher in ordinary glass test house due to greenhouse effect. Annual heating and cooling demand tests indicate that HISG provides 38 and 48% energy saving in heating and cooling season, respectively.
AtıfScopus52WoS46OpenAlex56İncele
- MakaleAçık Erişim2016Scopus SJRQ1The impact of internal aerogel retrofitting on the thermal bridges of residential buildings: An experimental and statistical research
Cuce, Erdem; Cuce, Pinar Mert
In this research, internal thermal superinsulation in residential buildings is experimentally and statistically evaluated in terms of potential thermal bridging effects. As a consequence of significant deviations in thermal resistance values in buildings at post-retrofit, large amounts of heat losses occur through non-insulated building elements such as separating walls. Therefore, it is of vital importance to determine the level of energy loss due to such thermal bridges through an internal thermal superinsulation retrofit conducted in a typical UK building. 20 mm thick fibre-silica opaque aerogel blanket is implemented internally on the walls of a test bedroom, and the heat flux from the separating wall is measured and compared for the cases of pre and post-retrofit. The results reveal that the average amount of heat loss through the non-insulated separating wall at the post-retrofit is 5.86 W/m2, whereas it is only 0.66 W/m2 at the pre-retrofit. The results are also verified through a statistical model, which is presented for the first time in literature. The novel model is capable of providing information about potential energy loss from non-insulated walls as a function of location.
AtıfScopus60WoS54OpenAlex69İncele
- Derleme MakaleYalnız künye2016Scopus SJRQ1Renewable and sustainable energy saving strategies for greenhouse systems: A comprehensive review
Cuce, Erdem; Harjunowibowo, Dewanto; Cuce, Pinar Mert
In this study, a comprehensive review focusing on key strategies of energy saving and climate control technologies for greenhouses is presented. Following the brief and concise assessment of existing greenhouse systems in terms of their role in total energy consumption; cost-effective, energy-efficient and environmentally friendly technologies are analyzed in detail for potential utilization in greenhouses for notable reductions in energy consumption and emission levels. The technologies considered within the scope of this research are mainly renewable and sustainable based solutions such as photovoltaic (PV) modules, solar thermal (T) collectors, hybrid PV/T collectors and systems, phase change material (PCM) and underground based heat storage techniques, energy-efficient heat pumps, alternative facade materials for better thermal insulation and power generation (heat insulation solar glass, PV glazing, aerogel and vacuum insulation panel, polycarbonate sandwich panels), innovative ventilation technologies using pre-heating and cooling (high performance windcatchers) and efficient lighting systems. The findings from the research clearly reveal that up to 80% energy saving can be achieved through appropriate retrofit of conventional greenhouses with a payback period of 4-8 years depending on climatic conditions and crop type.
AtıfScopus354WoS302OpenAlex382İncele







