Novel glazing technologies to mitigate energy consumption in low-carbon buildings: A comparative experimental investigation

MakaleAçık ErişimScopus SJRQ1
  • SDG 7 · Erişilebilir ve Temiz Enerji
  • SDG 13 · İklim Eylemi

Özet

Buildings play a key role in total world energy consumption as a consequence of poor thermal insulation characteristics of facade materials. Among the elements of a typical building envelope, windows are responsible for the greatest energy loss because of their notably high overall heat transfer coefficients. About 60% of heat loss through the building fabric can be attributed to the glazed areas. In this respect, novel cost-effective glazing technologies are needed to mitigate energy consumption, and thus to achieve the latest targets toward low/zero carbon buildings. Therefore in this study, three unique glazing products called vacuum tube window, heat insulation solar glass and solar pond window which have recently been developed at the University of Nottingham are introduced, and thermal performance analysis of each glazing technology is done through a comparative experimental investigation for the first time in literature. Standardized co-heating test methodology is performed, and overall heat transfer coefficient (U-value) is determined for each glazing product following the tests carried out in a calibrated environmental chamber. The research essentially aims at developing cost-effective solutions to mitigate energy consumption because of windows. The results indicate that each glazing technology provides very promising U-values which are incomparable with conventional commercial glazing products. Among the samples tested, the lowest U-value is obtained from the vacuum tube window by 0.40W/m2K, which corresponds to five times better thermal insulation ability compared to standard air filled double glazed windows.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/bayburt/12539Resmi atıflarda kullanılan kalıcı adres
DOI
https://doi.org/10.1002/er.3478Yayıncı resmi DOI adresi
İndeks kayıtları
Kaydın indeks veri tabanlarındaki sayfası (aktarımda alınan kayıt numarasıyla). Erişim, indeksin kendi koşullarına bağlıdır.
Atıflar
Scopus
35
WoS
33
OpenAlex
37
Her kaynağın kendi saydığı toplam atıf; aktarım ve zenginleştirme sırasında alındı.
Tam Kayıt
AlanDeğerDil
dc.contributor.authorCuce, Erdem
dc.contributor.authorCuce, Pinar Mert
dc.contributor.authorRiffat, Saffa
dc.date.accessioned2026-10-29T19:09:42.640871325Z
dc.date.available2026-10-29T19:09:42.640871325Z
dc.date.issued2016
dc.description.abstractBuildings play a key role in total world energy consumption as a consequence of poor thermal insulation characteristics of facade materials. Among the elements of a typical building envelope, windows are responsible for the greatest energy loss because of their notably high overall heat transfer coefficients. About 60% of heat loss through the building fabric can be attributed to the glazed areas. In this respect, novel cost-effective glazing technologies are needed to mitigate energy consumption, and thus to achieve the latest targets toward low/zero carbon buildings. Therefore in this study, three unique glazing products called vacuum tube window, heat insulation solar glass and solar pond window which have recently been developed at the University of Nottingham are introduced, and thermal performance analysis of each glazing technology is done through a comparative experimental investigation for the first time in literature. Standardized co-heating test methodology is performed, and overall heat transfer coefficient (U-value) is determined for each glazing product following the tests carried out in a calibrated environmental chamber. The research essentially aims at developing cost-effective solutions to mitigate energy consumption because of windows. The results indicate that each glazing technology provides very promising U-values which are incomparable with conventional commercial glazing products. Among the samples tested, the lowest U-value is obtained from the vacuum tube window by 0.40W/m2K, which corresponds to five times better thermal insulation ability compared to standard air filled double glazed windows.
dc.description.sponsorshipTUBITAK (Scientific and Technological Research Council of Turkey) [BIDEB 2219 2015/1]
dc.identifier.doi10.1002/er.3478
dc.identifier.eissn1099-114X
dc.identifier.endpage549
dc.identifier.issn0363-907X
dc.identifier.issue4
dc.identifier.scopus2-s2.0-84959493086
dc.identifier.startpage537
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/bayburt/12539
dc.identifier.volume40
dc.identifier.wosWOS:000371887400010
dc.language.isoen
dc.publisherJohn Wiley and Sons Ltd
dc.relation.ispartofInternational Journal of Energy Research
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectGlazing technologies
dc.subjectHeat insulation solar glass
dc.subjectSolar pond window
dc.subjectThermal insulation performance
dc.subjectU-value
dc.subjectVacuum tube window
dc.subject.classificationEnergy & Fuels
dc.subject.classificationNuclear Science & Technology
dc.subject.otherBuildings
dc.subject.otherCost effectiveness
dc.subject.otherElectron tubes
dc.subject.otherEnergy conservation
dc.subject.otherEnergy dissipation
dc.subject.otherEnergy utilization
dc.subject.otherEnvironmental chambers
dc.subject.otherGlass
dc.subject.otherGlazes
dc.subject.otherHeat transfer
dc.subject.otherHeat transfer coefficients
dc.subject.otherInsulation
dc.subject.otherLakes
dc.subject.otherSolar ponds
dc.subject.otherExperimental investigations
dc.subject.otherInsulation performance
dc.subject.otherLow/Zero Carbon buildings
dc.subject.otherOverall heat transfer coefficient
dc.subject.otherSolar glass
dc.subject.otherThermal insulation characteristics
dc.subject.otherThermal performance analysis
dc.subject.otherU values
dc.subject.otherThermal insulation
dc.titleNovel glazing technologies to mitigate energy consumption in low-carbon buildings: A comparative experimental investigation
dc.typeArticle
rdl.citation.openalex37
rdl.citation.scopus35
rdl.citation.wos33
rdl.oa.statusclosed
rdl.oa.statusgreen
rdl.oa.urlhttps://hdl.handle.net/20.500.12403/633
rdl.scopus.quartileQ1
rdl.sdgSDG13
rdl.sdgSDG07
rdl.source.indexSCOPUS
rdl.source.indexWOS