The impact of internal aerogel retrofitting on the thermal bridges of residential buildings: An experimental and statistical research

MakaleAçık ErişimScopus SJRQ1
  • SDG 11 · Sürdürülebilir Şehirler ve Topluluklar

Özet

In this research, internal thermal superinsulation in residential buildings is experimentally and statistically evaluated in terms of potential thermal bridging effects. As a consequence of significant deviations in thermal resistance values in buildings at post-retrofit, large amounts of heat losses occur through non-insulated building elements such as separating walls. Therefore, it is of vital importance to determine the level of energy loss due to such thermal bridges through an internal thermal superinsulation retrofit conducted in a typical UK building. 20 mm thick fibre-silica opaque aerogel blanket is implemented internally on the walls of a test bedroom, and the heat flux from the separating wall is measured and compared for the cases of pre and post-retrofit. The results reveal that the average amount of heat loss through the non-insulated separating wall at the post-retrofit is 5.86 W/m2, whereas it is only 0.66 W/m2 at the pre-retrofit. The results are also verified through a statistical model, which is presented for the first time in literature. The novel model is capable of providing information about potential energy loss from non-insulated walls as a function of location.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/bayburt/12330Resmi atıflarda kullanılan kalıcı adres
İndeks kayıtları
Kaydın indeks veri tabanlarındaki sayfası (aktarımda alınan kayıt numarasıyla). Erişim, indeksin kendi koşullarına bağlıdır.
Atıflar
Scopus
60
WoS
54
OpenAlex
69
Her kaynağın kendi saydığı toplam atıf; aktarım ve zenginleştirme sırasında alındı.
Tam Kayıt
AlanDeğerDil
dc.contributor.authorCuce, Erdem
dc.contributor.authorCuce, Pinar Mert
dc.date.accessioned2026-10-29T19:09:27.146120487Z
dc.date.available2026-10-29T19:09:27.146120487Z
dc.date.issued2016
dc.description.abstractIn this research, internal thermal superinsulation in residential buildings is experimentally and statistically evaluated in terms of potential thermal bridging effects. As a consequence of significant deviations in thermal resistance values in buildings at post-retrofit, large amounts of heat losses occur through non-insulated building elements such as separating walls. Therefore, it is of vital importance to determine the level of energy loss due to such thermal bridges through an internal thermal superinsulation retrofit conducted in a typical UK building. 20 mm thick fibre-silica opaque aerogel blanket is implemented internally on the walls of a test bedroom, and the heat flux from the separating wall is measured and compared for the cases of pre and post-retrofit. The results reveal that the average amount of heat loss through the non-insulated separating wall at the post-retrofit is 5.86 W/m2, whereas it is only 0.66 W/m2 at the pre-retrofit. The results are also verified through a statistical model, which is presented for the first time in literature. The novel model is capable of providing information about potential energy loss from non-insulated walls as a function of location.
dc.description.sponsorshipTürkiye Bilimsel ve Teknolojik Araştirma Kurumu, TÜBITAK, (BIDEB 2219 2015/1)
dc.identifier.doi10.1016/j.enbuild.2016.01.033
dc.identifier.eissn1872-6178
dc.identifier.endpage454
dc.identifier.issn0378-7788
dc.identifier.scopus2-s2.0-84957548056
dc.identifier.startpage449
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/bayburt/12330
dc.identifier.volume116
dc.identifier.wosWOS:000373863300040
dc.language.isoen
dc.publisherElsevier Ltd
dc.relation.ispartofEnergy and Buildings
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectEnergy loss
dc.subjectResidential buildings
dc.subjectThermal bridges
dc.subjectThermal superinsulation
dc.subject.classificationConstruction & Building Technology
dc.subject.classificationEnergy & Fuels
dc.subject.classificationEngineering, Civil
dc.subject.classificationEngineering
dc.subject.otherAerogels
dc.subject.otherBuildings
dc.subject.otherEnergy dissipation
dc.subject.otherHeat flux
dc.subject.otherHeat losses
dc.subject.otherHeat resistance
dc.subject.otherHousing
dc.subject.otherPotential energy
dc.subject.otherRetrofitting
dc.subject.otherSeparation
dc.subject.otherAerogel blankets
dc.subject.otherBuilding element
dc.subject.otherResidential building
dc.subject.otherStatistical modeling
dc.subject.otherStatistical research
dc.subject.otherThermal bridge
dc.subject.otherThermal bridging
dc.subject.otherThermal super-insulation
dc.subject.otherWalls (structural partitions)
dc.titleThe impact of internal aerogel retrofitting on the thermal bridges of residential buildings: An experimental and statistical research
dc.typeArticle
rdl.citation.openalex69
rdl.citation.scopus60
rdl.citation.wos54
rdl.oa.statusclosed
rdl.oa.statusgreen
rdl.oa.urlhttps://hdl.handle.net/20.500.12403/635
rdl.scopus.quartileQ1
rdl.sdgSDG11
rdl.source.indexSCOPUS
rdl.source.indexWOS
rdl.wos.indexScience Citation Index Expanded (SCI-EXPANDED)