Sürdürülebilir Kalkınma Amaçları
Yazarlar
Yayınlar
- MakaleAçık Erişim2026Scopus SJRQ2Bioinspired Sternal Implant Design for Generic Anatomical Reconstruction: An In Silico Framework for Material Selection and Biomechanical Validation
Kutbay, Işıl; Gerdan, Zeynep; Çolak, Murat; Tabak, Yasemin; Şensoy, Abdullah Tahir
The sternum protects the intrathoracic organs and contributes to chest wall mechanics, which makes reconstruction after tumor resection, trauma, or infection a demanding biomechanical problem. This study presents an in silico workflow for preselecting materials for sternal implants before physical prototyping. After a virtual resection, an anatomically conformal implant was designed and candidate biomaterials were screened in CES Selector using density, elastic modulus, fatigue strength, fracture toughness, toxicity, medical grade suitability, and MRI safety. A representative subset of the screened candidates was then compared by finite element modeling in terms of stress transfer and deformation. Seventeen candidates met the screening criteria. Ti-13Nb-13Zr showed an elastic modulus of about 80 GPa, and the titanium-based candidates showed deformation values of about 0.96 to 1.03 mm, whereas GF PEEK reached about 1.74 mm. The stress shielding index also showed that titanium-based materials remained on the implant-dominant side, while polymer-based materials shifted stress transfer toward bone. Taken together, the findings suggest that Ti-13Nb-13Zr offers the best overall balance for load-bearing sternal reconstruction, whereas PEEK-based systems may be more suitable within the present model for hybrid or adjunct designs. The proposed workflow can support early implant planning and guide future experimental and clinical studies.
- MakaleAçık Erişim2025Scopus SJRQ2Tri-method analysis of contact mechanics in orthotropic-isotropic materials
Öner, Erdal; Oktay, Mine Gül; Uzun Yaylacı, Ecren; Yaylacı, Murat; Mirzaloğlu, İrem
This study examines the contact mechanics of a homogeneous orthotropic layer resting on a homogeneous isotropic half-space without being bonded, subjected to loading by a rigid cylindrical punch. The effect of the orthotropic layer’s body force has been taken into account in the study. The study is conducted in three phases. In the first phase, the contact problem is analytically tackled using advanced methods such as elasticity theory, integral transform techniques, and Gauss–Chebyshev integration. The second phase utilizes finite element analysis through ANSYS software, accurately modeling the system. In the final phase, an artificial neural network is employed, allowing the system to learn and recognize intricate patterns in the data. The standout feature of this study is its thorough comparison of these three distinct methodologies, offering a comprehensive understanding of the contact mechanics between isotropic and orthotropic materials. The results reveal key insights into contact length, maximum contact stress, critical separation load, and separation distance, all as functions of critical dimensionless parameters. This study is significant in today’s advancing field of contact mechanics as it not only explores the combined impact of body forces and the interaction between orthotropic and isotropic materials but also uniquely compares the results using three distinct methods, offering comprehensive insights that address both theoretical and practical challenges.
AtıfScopus27WoS27OpenAlex22İncele
- MakaleAçık Erişim2021Scopus SJRQ3An application of finite element method in material selection for dental implant crowns
Sensoy, Abdullah T.; Çolak, Murat; Kaymaz, Irfan; Findik, Fehim
Materials used for dental crowns show a wide range of variety, and a dentist's choice can depend on several factors such as patient desires, esthetics, tooth factors, etc. One of the most important issues for implant surgery is the primary stability and it should be provided to minimize the risks of screw loosening, failed osseointegration, or nonunion. The current study aims to present the Finite Element Analysis (FEA)-based material selection strategy for a dental crown in terms of reducing the aforementioned risks of dental implants. A virtual surgery mandible model obtained using MIMICS software was transferred to the ANSYS and material candidates determined using CES software were compared using FEA. The results indicated that Zr02+Y2O3 (zirconia) has shown a 12.79% worse performance compared to Au83-88/Pt4-12/Pd4.5-6 alloy in terms of abutment loosening. On the other hand, zirconia is the most promising material for dental crowns in terms of the stability of the bone-implant complex. Therefore, it may show the best overall performance for clinical use. Moreover, as suggested in this study, a better outcome and more accurate predictions can be achieved using a patient-specific FEA approach for the material selection process.
AtıfScopus4WoS4OpenAlex5İncele
- MakaleAçık Erişim2019Scopus SJRQ2Optimal Material Selection for Total Hip Implant: A Finite Element Case Study
Şensoy, Abdullah Tahir; Çolak, Murat; Kaymaz, Irfan; Findik, Fehim
The selection of most proper materials in engineering design is known as an important stage of the design process. In order to successfully complete this stage, it is necessary to have sufficient knowledge about the structure of materials, density, melting point, thermal expansion coefficient, tensile and yield strength, elongation, modulus of elasticity, hardness and many other properties. There are several selection systems that help the design engineer to choose most suitable material that meet the required properties. In the field of bioengineering, the selection of materials and the development of new materials for the clinical needs are increasingly important. In this study, the cases of optimal implant stabilization were investigated, material alternatives for hip prosthesis were evaluated, and optimal materials were determined. Using computerized tomography data with MIMICS software, virtual surgery was applied the hip bone and the implant was attached to bone. Boundary conditions and material properties have been defined, and finite element model has been created. FEA investigation of the mechanical behavior of the hip implant for various material alternatives determined by the CES software showed that the best material candidate is austenitic, annealed and biodurable stainless steel in terms of the micromotions at the implant–bone cement interface regarding osseointegration. This candidate showed 20.69% less strain value than the most commercially used hip implant material, Ti6Al4V. Therefore, the findings of this study suggest that the use of some specific stainless steel materials for implants may reduce the operation cost and increase the operation success for the total hip arthroplasty.
AtıfScopus36WoS28OpenAlex41İncele