An application of finite element method in material selection for dental implant crowns

MakaleAçık ErişimScopus SJRQ3
  • SDG 3 · Sağlık ve Kaliteli Yaşam

Özet

Materials used for dental crowns show a wide range of variety, and a dentist's choice can depend on several factors such as patient desires, esthetics, tooth factors, etc. One of the most important issues for implant surgery is the primary stability and it should be provided to minimize the risks of screw loosening, failed osseointegration, or nonunion. The current study aims to present the Finite Element Analysis (FEA)-based material selection strategy for a dental crown in terms of reducing the aforementioned risks of dental implants. A virtual surgery mandible model obtained using MIMICS software was transferred to the ANSYS and material candidates determined using CES software were compared using FEA. The results indicated that Zr02+Y2O3 (zirconia) has shown a 12.79% worse performance compared to Au83-88/Pt4-12/Pd4.5-6 alloy in terms of abutment loosening. On the other hand, zirconia is the most promising material for dental crowns in terms of the stability of the bone-implant complex. Therefore, it may show the best overall performance for clinical use. Moreover, as suggested in this study, a better outcome and more accurate predictions can be achieved using a patient-specific FEA approach for the material selection process.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/bayburt/13272Resmi atıflarda kullanılan kalıcı adres
DOI
https://doi.org/10.1515/bmt-2020-0232Yayıncı resmi DOI adresi
İndeks kayıtları
Kaydın indeks veri tabanlarındaki sayfası (aktarımda alınan kayıt numarasıyla). Erişim, indeksin kendi koşullarına bağlıdır.
Atıflar
Scopus
4
WoS
4
OpenAlex
5
Her kaynağın kendi saydığı toplam atıf; aktarım ve zenginleştirme sırasında alındı.
Tam Kayıt
AlanDeğerDil
dc.contributor.authorSensoy, Abdullah T.
dc.contributor.authorÇolak, Murat
dc.contributor.authorKaymaz, Irfan
dc.contributor.authorFindik, Fehim
dc.date.accessioned2026-10-29T19:10:43.478371796Z
dc.date.available2026-10-29T19:10:43.478371796Z
dc.date.issued2021
dc.description.abstractMaterials used for dental crowns show a wide range of variety, and a dentist's choice can depend on several factors such as patient desires, esthetics, tooth factors, etc. One of the most important issues for implant surgery is the primary stability and it should be provided to minimize the risks of screw loosening, failed osseointegration, or nonunion. The current study aims to present the Finite Element Analysis (FEA)-based material selection strategy for a dental crown in terms of reducing the aforementioned risks of dental implants. A virtual surgery mandible model obtained using MIMICS software was transferred to the ANSYS and material candidates determined using CES software were compared using FEA. The results indicated that Zr02+Y2O3 (zirconia) has shown a 12.79% worse performance compared to Au83-88/Pt4-12/Pd4.5-6 alloy in terms of abutment loosening. On the other hand, zirconia is the most promising material for dental crowns in terms of the stability of the bone-implant complex. Therefore, it may show the best overall performance for clinical use. Moreover, as suggested in this study, a better outcome and more accurate predictions can be achieved using a patient-specific FEA approach for the material selection process.
dc.identifier.doi10.1515/bmt-2020-0232
dc.identifier.eissn1862-278X
dc.identifier.endpage436
dc.identifier.issn0013-5585
dc.identifier.issue4
dc.identifier.pmid33837682
dc.identifier.scopus2-s2.0-85104430505
dc.identifier.startpage429
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/bayburt/13272
dc.identifier.volume66
dc.identifier.wosWOS:000681637400011
dc.language.isoen
dc.publisherDe Gruyter Open Ltd
dc.relation.ispartofBiomedizinische Technik
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectbiomedical modeling
dc.subjectdental crown
dc.subjectfinite element analysis
dc.subjectimplant
dc.subjectmaterial selection
dc.subject.classificationEngineering, Biomedical
dc.subject.classificationMedical Informatics
dc.subject.classificationEngineering
dc.subject.otherRisk assessment
dc.subject.otherSurgery
dc.subject.otherTissue regeneration
dc.subject.otherZirconia
dc.subject.otherdental alloy
dc.subject.otherdental material
dc.subject.otherzirconium oxide
dc.subject.otherAccurate prediction
dc.subject.otherApplication of finite elements
dc.subject.otherMaterial candidate
dc.subject.otherMaterial selection
dc.subject.otherOsseointegration
dc.subject.otherPatient specific
dc.subject.otherPrimary stabilities
dc.subject.otherVirtual surgery
dc.subject.otherArticle
dc.subject.othercontrolled study
dc.subject.othercortical bone
dc.subject.otherelasticity
dc.subject.otherfinite element analysis
dc.subject.otherflexural strength
dc.subject.otherhardness
dc.subject.otherhuman
dc.subject.othertrabecular bone
dc.subject.otherFinite element method
dc.titleAn application of finite element method in material selection for dental implant crowns
dc.typeArticle
rdl.citation.openalex5
rdl.citation.scopus4
rdl.citation.wos4
rdl.departmentEngineering Faculty, Samsun University, Samsun, Turkey
rdl.departmentEngineering Faculty, Bayburt University, Bayburt, Turkey
rdl.departmentEngineering Faculty, Erzurum Technical University, Erzurum, Turkey
rdl.departmentFaculty of Technology, Sakarya Applied Sciences University, Sakarya, Turkey
rdl.departmentBIOENAMS Research Center, Sakarya University, Sakarya, Turkey
rdl.oa.statusgreen
rdl.oa.statuspreprint
rdl.oa.urlhttps://hdl.handle.net/20.500.14002/429
rdl.scopus.quartileQ3
rdl.sdgSDG03
rdl.source.indexSCOPUS
rdl.source.indexWOS
rdl.source.indexPUBMED
rdl.wos.indexScience Citation Index Expanded (SCI-EXPANDED)