The selection of most proper materials in engineering design is known as an important stage of the design process. In order to successfully complete this stage, it is necessary to have sufficient knowledge about the structure of materials, density, melting point, thermal expansion coefficient, tensile and yield strength, elongation, modulus of elasticity, hardness and many other properties. There are several selection systems that help the design engineer to choose most suitable material that meet the required properties. In the field of bioengineering, the selection of materials and the development of new materials for the clinical needs are increasingly important. In this study, the cases of optimal implant stabilization were investigated, material alternatives for hip prosthesis were evaluated, and optimal materials were determined. Using computerized tomography data with MIMICS software, virtual surgery was applied the hip bone and the implant was attached to bone. Boundary conditions and material properties have been defined, and finite element model has been created. FEA investigation of the mechanical behavior of the hip implant for various material alternatives determined by the CES software showed that the best material candidate is austenitic, annealed and biodurable stainless steel in terms of the micromotions at the implant–bone cement interface regarding osseointegration. This candidate showed 20.69% less strain value than the most commercially used hip implant material, Ti6Al4V. Therefore, the findings of this study suggest that the use of some specific stainless steel materials for implants may reduce the operation cost and increase the operation success for the total hip arthroplasty.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/bayburt/13527Resmi atıflarda kullanılan kalıcı adres
DOI
https://doi.org/10.1007/s13369-019-04088-yYayıncı resmi DOI adresi
İndeks kayıtları
Kaydın indeks veri tabanlarındaki sayfası (aktarımda alınan kayıt numarasıyla). Erişim, indeksin kendi koşullarına bağlıdır.
Atıflar
Scopus
36
WoS
28
OpenAlex
41
Her kaynağın kendi saydığı toplam atıf; aktarım ve zenginleştirme sırasında alındı.
Tam Kayıt
AlanDeğerDil
dc.contributor.authorŞensoy, Abdullah Tahir
dc.contributor.authorÇolak, Murat
dc.contributor.authorKaymaz, Irfan
dc.contributor.authorFindik, Fehim
dc.date.accessioned2026-10-29T19:11:06.324084724Z
dc.date.available2026-10-29T19:11:06.324084724Z
dc.date.issued2019
dc.description.abstractThe selection of most proper materials in engineering design is known as an important stage of the design process. In order to successfully complete this stage, it is necessary to have sufficient knowledge about the structure of materials, density, melting point, thermal expansion coefficient, tensile and yield strength, elongation, modulus of elasticity, hardness and many other properties. There are several selection systems that help the design engineer to choose most suitable material that meet the required properties. In the field of bioengineering, the selection of materials and the development of new materials for the clinical needs are increasingly important. In this study, the cases of optimal implant stabilization were investigated, material alternatives for hip prosthesis were evaluated, and optimal materials were determined. Using computerized tomography data with MIMICS software, virtual surgery was applied the hip bone and the implant was attached to bone. Boundary conditions and material properties have been defined, and finite element model has been created. FEA investigation of the mechanical behavior of the hip implant for various material alternatives determined by the CES software showed that the best material candidate is austenitic, annealed and biodurable stainless steel in terms of the micromotions at the implant–bone cement interface regarding osseointegration. This candidate showed 20.69% less strain value than the most commercially used hip implant material, Ti6Al4V. Therefore, the findings of this study suggest that the use of some specific stainless steel materials for implants may reduce the operation cost and increase the operation success for the total hip arthroplasty.
dc.identifier.doi10.1007/s13369-019-04088-y
dc.identifier.eissn2191-4281
dc.identifier.endpage10301
dc.identifier.issn2193-567X
dc.identifier.issue12
dc.identifier.scopus2-s2.0-85070221569
dc.identifier.startpage10293
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/bayburt/13527
dc.identifier.volume44
dc.identifier.wosWOS:000497394300039
dc.language.isoen
dc.publisherSpringer Verlag
dc.relation.ispartofArabian Journal for Science and Engineering
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectCES
dc.subjectFinite element analysis
dc.subjectHip prosthesis
dc.subjectImplant
dc.subjectOptimal material
dc.subjectSelection
dc.subject.classificationMultidisciplinary Sciences
dc.subject.classificationScience & Technology - Other Topics
dc.subject.otherKNOWLEDGE-BASED SYSTEM
dc.subject.otherMECHANICAL-PROPERTIES
dc.subject.otherPRODUCT DESIGN
dc.subject.otherTI
dc.subject.otherBIOCOMPATIBILITY
dc.subject.otherPROSTHESIS
dc.subject.otherSTABILITY
dc.subject.otherMATRIX
dc.subject.otherHA
dc.titleOptimal Material Selection for Total Hip Implant: A Finite Element Case Study
dc.typeArticle
rdl.citation.openalex41
rdl.citation.scopus36
rdl.citation.wos28
rdl.oa.statusgreen
rdl.oa.statuspreprint
rdl.oa.urlhttps://hdl.handle.net/20.500.14002/494
rdl.scopus.quartileQ2
rdl.sdgSDG03
rdl.source.indexSCOPUS
rdl.source.indexWOS
rdl.wos.indexScience Citation Index Expanded (SCI-EXPANDED)