Sürdürülebilir Kalkınma Amaçları
Yazarlar
Yayınlar
- MakaleAçık Erişim2023Scopus SJRQ2Investigation of organic and inorganic matters removal from tannery wastewater using iron plate electrode by electrocoagulation process
Bingül, Züleyha; Irdemez, Şahset; Kul, Sinan; Ekmekyapar Torun, Fatma; Demircioğlu, Nuhi
In this study, COD, turbidity, total nitrogen, phosphate, sulphate, oil-grease and chromium removals from wastewaters taken from a local tannery using the electrocoagulation process were examined and the most suitable parameters for the electrocoagulation system were tried to be determined. Soluble iron plate electrodes were used as electrodes in the experiments. As a result of the studies carried out, the most suitable initial pH in uncontrolled pH was determined as pH = 4 and for controlled pH as pH = 5. In studies, the most suitable current density for iron electrodes was determined as 1.2 mA cm−2. Even if the increase in current density increased the amount of dissolved Fe, it negatively affected the removal efficiency. In addition, the turbidity of the wastewater was removed in 30 minutes, phosphate in 20 minutes and chromium in 15 minutes by 100%. During 60 minutes of operation, while 62.91% of TN, 87.8% of oil-grease were removed, sulphate was removed at the rate of 54.78%. In the studies, 1st and 2nd order kinetic equations for COD removal were examined and it was determined that removal kinetic is more suitable for 2nd order kinetics.
AtıfScopus7WoS4İncele
- MakaleAçık Erişim2022Scopus SJRQ2The Investigation of COD Treatment and Energy Consumption of Urban Wastewater by a Continuous Electrocoagulation System
Dede Sağsöz, Yeşim; Yilmaz, Alper Erdem; Ekmekyapar Torun, Fatma; Kocadağistan, Beyhan; Kul, Sinan
In this study, electrochemical treatment of urban wastewater with electrical conductivity of 1000 µS cm-1 and chemical oxygen demand of 250 mg L-1 was investigated using the variables of initial pH value, current density and flow rate. Electrocoagulation was used, in which aluminum and stainless steel were selected, as the electrochemical treatment process. The electrocoagulation process was operated in continuous mode. The data obtained in experimental studies show that the best COD removal efficiency occurred in experiments where the initial pH value was 6. The increase in current density from 5 A to 15 A decreased the removal efficiency from 79 to 67%. The increase in flow rate under constant current density also reduced the efficiency of removal as expected. In experiments in which current density and flow rate were examined together, the increase in flow rate allowed the application of higher current densities. This situation led to considerable reductions in energy consumption values, even if the COD removal efficiency did not significantly increase. The high COD removal obtained with the use of high flow rate and high current density indicates that the electrocoagulation process can be used for high flow rate municipal wastewater treatment.
AtıfScopus6WoS5OpenAlex5İncele
- MakaleAçık Erişim2022Investigation of the effect of current density and PH on oil and grease removal from leather industry wastewaters by electrocoagulation method
Bi̇Ngül Reçber, Züleyha; Ekmekyapar Torun, Fatma; Kul, Sinan; İRdemez, Şahset
In this study, the effects of pH and current density on the removal of high concentrations of oil and grease in leather industry wastewater by the electrocoagulation method were investigated. Two different types of electrodes were used in the study. Studies with aluminum electrodes have shown that these electrodes are more effective than iron electrodes in removing oil and grease. In addition, aluminum electrodes are affected more by the system pH than iron electrodes. Studies have shown that higher oil and grease removal efficiencies are obtained below pH 4 for both electrodes. While the oil and grease removal efficiency with Al electrodes is 95% at pH 2, this value decreases to 83% at pH 6. In Fe electrodes, while the removal efficiency is 87.83% at pH 2, it decreases to 83% at pH 6. The effect of current density on oil and grease removal was examined and it was observed that the removal efficiency remained constant above a certain current density in aluminum electrodes. While the efficiency of Al electrodes is 83.31% at 0.6 mA cm-2 current density, this value has increased to about 98% at 1.2, 1.8, and 2.4 mA cm-2 current densities. In Fe electrodes, the oil and grease removal efficiency is 82.66% at 0.6 mA cm-2 current density, while it is 90% at 1.2 and 1.8 mA cm-2 current densities and 98% at 2.4 mA cm-2. These results show that the electrocoagulation process removes the oil and grease in wastewater at a high rate. This shows that this process can also be used as pre-treatment before the biological treatment of industrial wastewater with high oil and grease content. Copyright 2021, Yıldız Technical University.
AtıfScopus2WoS2OpenAlex1İncele
- MakaleAçık Erişim2021Scopus SJRQ4The effect of pH on removal of phosphate from water using aluminum electrodes by electrocoagulation method; [Alüminyum elektrotlar kullanılarak elektrokoagülasyon yöntemi ile sulardan fosfat gideriminde pH'ın etkisi]
İrdemez, Şahset; Bingül, Züleyha; Kul, Sinan; Ekmekyapar Torun, Fatma; Demircioğlu, Nuhi
In this study, the effect of wastewater pH on phosphate removal by electrocoagulation method using aluminum plate electrodes was investigated. For this purpose, experiments were carried out at initial pH values ranging from 3-10, and the effect of the initial pH of the wastewater on phosphate removal efficiency, energy consumption and reaction rate was analyzed. From the results obtained, it was determined that the initial pHs of the optimum wastewater was 3 and 4. Because at low pH, both phosphate removal efficiency is high and the energy consumption of the system is low. While 97% removal efficiency is reached in 20 minutes at pHi=3, it increases in this period with the increase of the wastewater initial pH. These data show that the removal rate is higher at lower initial pHs. While the 1st degree reaction rate constant at pHi=3 is k1=0.2154 min-1, this value decreases to k1=0.071 min-1 at pHi=10. At pHi=3, the energy consumption of the system has been determined as 0.553 kWh m-3 in 12 minutes of contact time. In addition, in the measurements made during the trials, it was observed that the highest PO4-P removal occurred during the period when the pH of the system was between 5-7.
AtıfScopus4OpenAlex1
İncele - MakaleYalnız künye2008Scopus SJRQ1The removal of lignin and phenol from paper mill effluents by electrocoagulation
Uǧurlu, M.; Gürses, A.; Doǧar, Ç.; Yalçin, M.
This study aims to investigate the treatment of paper mill effluents using electrocoagulation. Removal of lignin, phenol, chemical oxygen demand (COD) and biological oxygen demand (BOD) from paper mill effluents was investigated at various current intensities by using different electrodes (Al and Fe) and at various electrolysis times (1.0, 2.5, 5.0 and 7.5 min). It was observed that the experiments carried out at 12 V, an electrolysis time of 2 min and a current intensity of 77.13 mA were sufficient for the removal of these pollutants with each electrode. The removal capacities of the process using an Al electrode were 80% of lignin, 98% of phenol, 70% of BOD, and 75% of COD after 7.5 min. Using an Fe electrode the removal capacities were 92%, 93%, 80% and 55%, respectively. In addition, it was found that removal of lignin, phenol, BOD and COD increased with increasing current intensity. In the experiments carried out at different current intensities, higher removal can be explained through a decrease in intra-resistance of solution and consequently an increase at the transfer speed of organic species to electrodes. It was also found that Al electrode performs higher efficiency than Fe electrode except for COD removal. However, the time required for removal of BOD was more than that of COD. The results suggest that electrocoagulation could be considered as an effective alternative to paper mill effluents treatment.
AtıfScopus257OpenAlex275İncele



