Sürdürülebilir Kalkınma Amaçları

Bu dergideki yayınlar

5 →
  • MakaleYalnız künye2018Scopus SJRQ1
    Accurate and reliable U-value assessment of argon-filled double glazed windows: A numerical and experimental investigation

    Cuce, Erdem

    U-value assessment is a significant process to be able to evaluate the thermal insulation performance of building materials notably windows. About 60% of energy losses from building envelope is attributed to windows, hence accurate and reliable thermal resistance evaluation of glazed areas is of vital importance for a sensitive energy demand analysis of buildings. U-value assessment of windows is usually conducted through theoretical and numerical methods in literature. However, dwellers frequently complain about the insufficient thermal insulation performance of commercial glazing products when compared to the reported U-values in datasheets. This inconvenience arises from the lack of comprehensive experimental tests which simulate the actual operating conditions. Therefore, in this research, argon filled double glazed windows, which is one the most common fenestration products in market, is numerically and experimentally analysed in terms of U-value performance. Although computational fluid dynamics (CFD) analyses reveal that the U-value of the reference sample (4 mm pane + 20 mm argon + 4 mm pane) is 0.89 W/m(2)K, which is in good accordance with the theoretical data (0.80 W/m(2)K), it is observed from the environmental chamber tests that the U-value in simulated operating conditions is 1.25, 1.18 and 1.32 W/m(2)K for top, centre and lower positions of the window sample. The tests are repeated for accuracy verification, and the U-value is found to be 1.23, 1.18 and 1.31 W/m(2)K for the said points. In this respect, it is concluded that thermal bridges and edge effects play a key role in actual U-value performance of glazing products. Therefore, experimental performance figures are recommended to be utilised in energy demand analyses of buildings. (C) 2018 Elsevier B.V. All rights reserved.

    AtıfWoS72OpenAlex90
    Web of Scienceİncele
  • MakaleAçık Erişim2017Scopus SJRQ1
    Thermal performance assessment of a novel liquid desiccant-based evaporative cooling system: An experimental investigation

    Cuce, Pinar Mert

    Energy consumption in buildings due to heating, cooling and air conditioning (HVAC) systems has a steadily growing trend as a consequence of enhanced indoor thermal comfort conditions. The role of cooling in HVAC oriented energy consumption is remarkable especially in regions with extreme climatic conditions such as Africa and Middle East. In hot and arid climates, cooling demand is usually met by cost-effective evaporative cooling solutions. However, in hot and humid climates, evaporative cooling systems are not capable of providing cooling as the outdoor air is already almost saturated in most cases. Therefore in this research, a novel desiccant-based evaporative cooling system is presented. For different values of inlet supply air temperature and relative humidity provided by a standard environmental chamber, temperature and relative humidity values are measured experimentally at the inlet and outlet of dehumidification and humidification unit, respectively. Since the main purpose of the system developed is to provide cost-effective thermal comfort conditions especially in humid climates, dehumidification effectiveness is calculated for each case tested. The results indicate that the system provides attractive findings for temperate and humid climatic conditions, where stand-alone evaporative cooling systems are inconclusive. For a case of average inlet relative humidity of 94.7% and average inlet air temperature of 38.6 °C, the average outlet relative humidity and air temperature are determined to be 65.5% and 33.3 °C, respectively. An average of 5.3 °C reduction is achieved in supply air temperature as well as an average of 63.7% dehumidification effectiveness which is attractive and promising.

    • SDG 7 · Erişilebilir ve Temiz Enerji
    • SDG 13 · İklim Eylemi
    AtıfScopus35WoS32OpenAlex37
    ScopusWeb of Scienceİncele
  • MakaleYalnız künye2017Scopus SJRQ1
    Role of airtightness in energy loss from windows: Experimental results from in-situ tests

    Cuce, Erdem

    The rate of air leakage related energy loss from glazed areas is unequivocal especially in older and poorly installed windows. Therefore, in this research, a comprehensive experimental investigation is done to analyse the importance of air leakage on overall heat transfer coefficient (U-value) of conventional air filled double glazed windows. The tests are conducted in a typical UK dwelling of Nottingham fitted with traditional air filled double glazed windows. One sash of the test window is sealed internally with a special transparent cover to provide excellent airtightness whereas the second window sash is left as it is to represent the ordinary case. The experiments are conducted in April 2016, and dynamic co-heating test methodology is applied to evaluate the rate of enhancement in the U-value of airtight window sash. The results indicate that the airtight window sash has a notably lower U-value compared to the ordinary window sash due to the impact of airtightness and reverse heat flux during noon time owing to the greenhouse effect between transparent cover and internal glazing. The overall U-value of ordinary window sash is found to be 2.67 W/m2K, whereas it is 1.79 W/m2K for airtight window sash. It is observed that about 33% of reduction in heat losses can be achieved via airtight windows.

    • SDG 7 · Erişilebilir ve Temiz Enerji
    • SDG 13 · İklim Eylemi
    AtıfScopus60WoS59OpenAlex75
    ScopusWeb of Scienceİncele
  • MakaleAçık Erişim2016Scopus SJRQ1
    A novel roof type heat recovery panel for low-carbon buildings: An experimental investigation

    Cuce, Pinar Mert; Cuce, Erdem; Riffat, Saffa

    Energy saving and its efficient utilization is of prime interest in today's world due to the limited energy resources and growing significance of environmental issues. Despite the intensive efforts to narrow the gap between conventional energy sources (wood, coal, gas, oil, etc.) and renewables, renewable energy resources currently supply only about 14% of total world energy demand. In this regard, energy management and optimization are considered compulsory as much as the clean energy generation. Recent works indicate that the buildings play a significant role on global energy consumption. They are responsible for about 40% of global energy demand. Among the different building types, domestic buildings have the largest share with 63% and most of energy is utilized for heating, ventilation and air conditioning (HVAC) systems in those buildings. Energy consumption levels of buildings can be notably reduced through waste heat recovery in HVAC systems. There are several attempts in literature addressing the possibility of decreasing energy consumption of buildings via waste heat recovery technologies. The heat recovery technologies are cost effective and user friendly applications. The use of heat recovery systems aims at mitigating the energy consumption for HVAC applications as well as the greenhouse gas emissions, and hence decreasing the adverse effects of global warming on the Earth. It is well-documented in literature that the heat recovery systems are very promising for domestic applications. In this paper, experimental results of a novel heat recovery system developed for low-carbon buildings are presented. The proposed heat recovery system consists of a plate-type heat exchanger, blower fans and ducts. The parallel-flow arrangement is used to run the system. The system is designed as under roof application. The aim of the system is to recover waste heat and to preheat fresh air using stale air. The experiments of the system are carried out in winter season in Kent, UK. The study aims to investigate the coefficient of performance (COP) of the system as well as the heat recovery efficiency. The results show that the heat recovery efficiency of the proposed system is around 89% while the COP is 4.5. The proposed system can be used in both winter and summer conditions without requiring additional work. Its labor cost is extremely low, so it is cost-effective and user friendly.

    • SDG 7 · Erişilebilir ve Temiz Enerji
    • SDG 11 · Sürdürülebilir Şehirler ve Topluluklar
    • SDG 12 · Sorumlu Üretim ve Tüketim
    • SDG 13 · İklim Eylemi
    AtıfScopus28WoS23OpenAlex31
    ScopusWeb of Scienceİncele
  • MakaleAçık Erişim2016Scopus SJRQ1
    The impact of internal aerogel retrofitting on the thermal bridges of residential buildings: An experimental and statistical research

    Cuce, Erdem; Cuce, Pinar Mert

    In this research, internal thermal superinsulation in residential buildings is experimentally and statistically evaluated in terms of potential thermal bridging effects. As a consequence of significant deviations in thermal resistance values in buildings at post-retrofit, large amounts of heat losses occur through non-insulated building elements such as separating walls. Therefore, it is of vital importance to determine the level of energy loss due to such thermal bridges through an internal thermal superinsulation retrofit conducted in a typical UK building. 20 mm thick fibre-silica opaque aerogel blanket is implemented internally on the walls of a test bedroom, and the heat flux from the separating wall is measured and compared for the cases of pre and post-retrofit. The results reveal that the average amount of heat loss through the non-insulated separating wall at the post-retrofit is 5.86 W/m2, whereas it is only 0.66 W/m2 at the pre-retrofit. The results are also verified through a statistical model, which is presented for the first time in literature. The novel model is capable of providing information about potential energy loss from non-insulated walls as a function of location.

    • SDG 11 · Sürdürülebilir Şehirler ve Topluluklar
    AtıfScopus60WoS54OpenAlex69
    ScopusWeb of Scienceİncele
Tam Kayıt
AlanDeğerDil
creativeworkseries.issn0378-7788
dc.date.accessioned2026-10-29T19:09:27.192626864Z
dc.date.available2026-10-29T19:09:27.192626864Z
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/bayburt/12331
dc.publisherElsevier Ltd
dc.rightsinfo:eu-repo/semantics/openAccess
dc.titleEnergy and Buildings