Role of airtightness in energy loss from windows: Experimental results from in-situ tests

MakaleYalnız künyeScopus SJRQ1
  • SDG 7 · Erişilebilir ve Temiz Enerji
  • SDG 13 · İklim Eylemi

Özet

The rate of air leakage related energy loss from glazed areas is unequivocal especially in older and poorly installed windows. Therefore, in this research, a comprehensive experimental investigation is done to analyse the importance of air leakage on overall heat transfer coefficient (U-value) of conventional air filled double glazed windows. The tests are conducted in a typical UK dwelling of Nottingham fitted with traditional air filled double glazed windows. One sash of the test window is sealed internally with a special transparent cover to provide excellent airtightness whereas the second window sash is left as it is to represent the ordinary case. The experiments are conducted in April 2016, and dynamic co-heating test methodology is applied to evaluate the rate of enhancement in the U-value of airtight window sash. The results indicate that the airtight window sash has a notably lower U-value compared to the ordinary window sash due to the impact of airtightness and reverse heat flux during noon time owing to the greenhouse effect between transparent cover and internal glazing. The overall U-value of ordinary window sash is found to be 2.67 W/m2K, whereas it is 1.79 W/m2K for airtight window sash. It is observed that about 33% of reduction in heat losses can be achieved via airtight windows.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/bayburt/12562Resmi atıflarda kullanılan kalıcı adres
İndeks kayıtları
Kaydın indeks veri tabanlarındaki sayfası (aktarımda alınan kayıt numarasıyla). Erişim, indeksin kendi koşullarına bağlıdır.
Atıflar
Scopus
60
WoS
59
OpenAlex
75
Her kaynağın kendi saydığı toplam atıf; aktarım ve zenginleştirme sırasında alındı.
Tam Kayıt
AlanDeğerDil
dc.contributor.authorCuce, Erdem
dc.date.accessioned2026-10-29T19:09:44.006275495Z
dc.date.available2026-10-29T19:09:44.006275495Z
dc.date.issued2017
dc.description.abstractThe rate of air leakage related energy loss from glazed areas is unequivocal especially in older and poorly installed windows. Therefore, in this research, a comprehensive experimental investigation is done to analyse the importance of air leakage on overall heat transfer coefficient (U-value) of conventional air filled double glazed windows. The tests are conducted in a typical UK dwelling of Nottingham fitted with traditional air filled double glazed windows. One sash of the test window is sealed internally with a special transparent cover to provide excellent airtightness whereas the second window sash is left as it is to represent the ordinary case. The experiments are conducted in April 2016, and dynamic co-heating test methodology is applied to evaluate the rate of enhancement in the U-value of airtight window sash. The results indicate that the airtight window sash has a notably lower U-value compared to the ordinary window sash due to the impact of airtightness and reverse heat flux during noon time owing to the greenhouse effect between transparent cover and internal glazing. The overall U-value of ordinary window sash is found to be 2.67 W/m2K, whereas it is 1.79 W/m2K for airtight window sash. It is observed that about 33% of reduction in heat losses can be achieved via airtight windows.
dc.description.sponsorshipTürkiye Bilimsel ve Teknolojik Araştirma Kurumu, TÜBITAK, (BIDEB2219 2015/1)
dc.identifier.doi10.1016/j.enbuild.2017.01.027
dc.identifier.eissn1872-6178
dc.identifier.endpage455
dc.identifier.issn0378-7788
dc.identifier.scopus2-s2.0-85009955995
dc.identifier.startpage449
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/bayburt/12562
dc.identifier.volume139
dc.identifier.wosWOS:000395599200042
dc.language.isoen
dc.publisherElsevier Ltd
dc.relation.ispartofEnergy and Buildings
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.subjectAir leakage
dc.subjectAirtightness
dc.subjectDouble glazed windows
dc.subjectEnergy saving
dc.subjectHeat loss
dc.subjectU-value
dc.subject.classificationConstruction & Building Technology
dc.subject.classificationEnergy & Fuels
dc.subject.classificationEngineering, Civil
dc.subject.classificationEngineering
dc.subject.otherEnergy conservation
dc.subject.otherEnergy dissipation
dc.subject.otherGreenhouse effect
dc.subject.otherHeat flux
dc.subject.otherHeat losses
dc.subject.otherHeat transfer
dc.subject.otherAir leakage
dc.subject.otherAirtightness
dc.subject.otherCo-heating
dc.subject.otherDouble-glazed window
dc.subject.otherExperimental investigations
dc.subject.otherIn-situ test
dc.subject.otherOverall heat transfer coefficient
dc.subject.otherU values
dc.subject.otherWindows
dc.titleRole of airtightness in energy loss from windows: Experimental results from in-situ tests
dc.typeArticle
rdl.citation.openalex75
rdl.citation.scopus60
rdl.citation.wos59
rdl.oa.statusclosed
rdl.scopus.quartileQ1
rdl.sdgSDG13
rdl.sdgSDG07
rdl.source.indexSCOPUS
rdl.source.indexWOS
rdl.wos.indexScience Citation Index Expanded (SCI-EXPANDED)