Accurate and reliable U-value assessment of argon-filled double glazed windows: A numerical and experimental investigation

MakaleYalnız künyeScopus SJRQ1

Özet

U-value assessment is a significant process to be able to evaluate the thermal insulation performance of building materials notably windows. About 60% of energy losses from building envelope is attributed to windows, hence accurate and reliable thermal resistance evaluation of glazed areas is of vital importance for a sensitive energy demand analysis of buildings. U-value assessment of windows is usually conducted through theoretical and numerical methods in literature. However, dwellers frequently complain about the insufficient thermal insulation performance of commercial glazing products when compared to the reported U-values in datasheets. This inconvenience arises from the lack of comprehensive experimental tests which simulate the actual operating conditions. Therefore, in this research, argon filled double glazed windows, which is one the most common fenestration products in market, is numerically and experimentally analysed in terms of U-value performance. Although computational fluid dynamics (CFD) analyses reveal that the U-value of the reference sample (4 mm pane + 20 mm argon + 4 mm pane) is 0.89 W/m(2)K, which is in good accordance with the theoretical data (0.80 W/m(2)K), it is observed from the environmental chamber tests that the U-value in simulated operating conditions is 1.25, 1.18 and 1.32 W/m(2)K for top, centre and lower positions of the window sample. The tests are repeated for accuracy verification, and the U-value is found to be 1.23, 1.18 and 1.31 W/m(2)K for the said points. In this respect, it is concluded that thermal bridges and edge effects play a key role in actual U-value performance of glazing products. Therefore, experimental performance figures are recommended to be utilised in energy demand analyses of buildings. (C) 2018 Elsevier B.V. All rights reserved.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/bayburt/14398Resmi atıflarda kullanılan kalıcı adres
İndeks kayıtları
Kaydın indeks veri tabanlarındaki sayfası (aktarımda alınan kayıt numarasıyla). Erişim, indeksin kendi koşullarına bağlıdır.
Atıflar
WoS
72
OpenAlex
90
Her kaynağın kendi saydığı toplam atıf; aktarım ve zenginleştirme sırasında alındı.
Tam Kayıt
AlanDeğerDil
dc.contributor.authorCuce, Erdem
dc.date.accessioned2026-10-29T19:15:48.851942241Z
dc.date.available2026-10-29T19:15:48.851942241Z
dc.date.issued2018-07
dc.description.abstractU-value assessment is a significant process to be able to evaluate the thermal insulation performance of building materials notably windows. About 60% of energy losses from building envelope is attributed to windows, hence accurate and reliable thermal resistance evaluation of glazed areas is of vital importance for a sensitive energy demand analysis of buildings. U-value assessment of windows is usually conducted through theoretical and numerical methods in literature. However, dwellers frequently complain about the insufficient thermal insulation performance of commercial glazing products when compared to the reported U-values in datasheets. This inconvenience arises from the lack of comprehensive experimental tests which simulate the actual operating conditions. Therefore, in this research, argon filled double glazed windows, which is one the most common fenestration products in market, is numerically and experimentally analysed in terms of U-value performance. Although computational fluid dynamics (CFD) analyses reveal that the U-value of the reference sample (4 mm pane + 20 mm argon + 4 mm pane) is 0.89 W/m(2)K, which is in good accordance with the theoretical data (0.80 W/m(2)K), it is observed from the environmental chamber tests that the U-value in simulated operating conditions is 1.25, 1.18 and 1.32 W/m(2)K for top, centre and lower positions of the window sample. The tests are repeated for accuracy verification, and the U-value is found to be 1.23, 1.18 and 1.31 W/m(2)K for the said points. In this respect, it is concluded that thermal bridges and edge effects play a key role in actual U-value performance of glazing products. Therefore, experimental performance figures are recommended to be utilised in energy demand analyses of buildings. (C) 2018 Elsevier B.V. All rights reserved.
dc.description.sponsorshipTUBITAK (The Scientific and Technological Research Council of Turkey) [216M531]
dc.identifier.doi10.1016/j.enbuild.2018.04.036
dc.identifier.eissn1872-6178
dc.identifier.endpage106
dc.identifier.issn0378-7788
dc.identifier.startpage100
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/bayburt/14398
dc.identifier.volume171
dc.identifier.wosWOS:000435625800009
dc.language.isoen
dc.publisherELSEVIER SCIENCE SA
dc.relation.ispartofENERGY AND BUILDINGS
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.subjectU-value assessment
dc.subjectDouble glazed windows
dc.subjectThermal resistance
dc.subjectEnergy losses in buildings
dc.subject.classificationConstruction & Building Technology
dc.subject.classificationEnergy & Fuels
dc.subject.classificationEngineering, Civil
dc.subject.classificationEngineering
dc.subject.otherGLAZING TECHNOLOGIES
dc.subject.otherCARBON BUILDINGS
dc.subject.otherPRODUCT
dc.titleAccurate and reliable U-value assessment of argon-filled double glazed windows: A numerical and experimental investigation
dc.typeArticle
rdl.citation.openalex90
rdl.citation.wos72
rdl.oa.statusclosed
rdl.scopus.quartileQ1
rdl.source.indexWOS
rdl.wos.indexScience Citation Index Expanded (SCI-EXPANDED)