Yazarlar
Yayınlar
- MakaleYalnız künye2023Scopus SJRQ1Honey-Water Content Analysis by Mixing Models Using a Self-Calibrating Microwave Method
Hasar, Hafize; Hasar, Ugur C.; Kaya, Yunus; Ozturk, Hamdullah; Izginli, Mucahit; Oztas, Taskin; Aslan, Nevzat; Ertugrul, Mehmet; Barroso, Joaquim J.; Ramahi, Omar M.
Microwave techniques, as an indirect approach, can be applied for analyzing water content in honey by way of permittivity measurements. However, these techniques require proper calibration to accurately perform such indirect evaluation. Improper calibration standards used in this calibration process could naturally result in a reduction in the accuracy and thus the performance of dielectric characterization using microwaves. Self-calibrating microwave techniques can reduce the effects of imprecise standards and thus improve the performance of microwave measurements by bypassing the requirement of calibration standards. In this study, we develop a self-calibrating microwave measurement technique to determine the relative permittivity of honey samples and implement binary mixing models to predict adulteration levels of water-adulterated honey. From this implementation, it is observed that the parallel-capacitance mixing model could efficiently be applied to determine the concentration of water adulteration by examining the differences between absolute values of the real parts of the measured and predicted complex permittivities of adulterated honey.
AtıfScopus18WoS16OpenAlex18İncele
- MakaleAçık Erişim2018Scopus SJRQ1Self-Calibrating Noniterative Complex Permittivity Extraction of Thin Dielectric Samples
Hasar, Ugur Cem; Kaya, Yunus
A microwave method relying on uncalibrated scattering (S-) parameters is proposed to measure the complex permittivity (ϵr) of thin dielectric samples. It has the following two main advantages. First, it takes into account effect of the sample holder, used for holding the sample, especially important for thin sample electromagnetic property characterization. Second, it does not require any specific information about the location of the sample (and its holder) inside its measurement cell for ϵr extraction. For validation of our method, we applied a commercial three-dimensional electromagnetic simulation program-CST Microwave Studio-and the Lorentz dispersion model. Uncalibrated (as well as calibrated) S-parameter measurements were conducted to measure ϵr of a 0.7 mm thick polyethylene sample (the sample holder was a 5.18 mm thick PVC sample) by our method and other similar methods in the literature. From the comparison, we observed that while the accuracy of tested methods significantly changed with inaccurate knowledge of the sample position inside its cell, the accuracy of our method did not much alter.
AtıfScopus18WoS16OpenAlex18İncele
