Honey-Water Content Analysis by Mixing Models Using a Self-Calibrating Microwave Method

MakaleYalnız künyeScopus SJRQ1

Özet

Microwave techniques, as an indirect approach, can be applied for analyzing water content in honey by way of permittivity measurements. However, these techniques require proper calibration to accurately perform such indirect evaluation. Improper calibration standards used in this calibration process could naturally result in a reduction in the accuracy and thus the performance of dielectric characterization using microwaves. Self-calibrating microwave techniques can reduce the effects of imprecise standards and thus improve the performance of microwave measurements by bypassing the requirement of calibration standards. In this study, we develop a self-calibrating microwave measurement technique to determine the relative permittivity of honey samples and implement binary mixing models to predict adulteration levels of water-adulterated honey. From this implementation, it is observed that the parallel-capacitance mixing model could efficiently be applied to determine the concentration of water adulteration by examining the differences between absolute values of the real parts of the measured and predicted complex permittivities of adulterated honey.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/bayburt/11824Resmi atıflarda kullanılan kalıcı adres
DOI
https://doi.org/10.1109/tmtt.2022.3208024Yayıncı resmi DOI adresi
İndeks kayıtları
Kaydın indeks veri tabanlarındaki sayfası (aktarımda alınan kayıt numarasıyla). Erişim, indeksin kendi koşullarına bağlıdır.
Atıflar
Scopus
18
WoS
16
OpenAlex
18
Her kaynağın kendi saydığı toplam atıf; aktarım ve zenginleştirme sırasında alındı.
Tam Kayıt
AlanDeğerDil
dc.contributor.authorHasar, Hafize
dc.contributor.authorHasar, Ugur C.
dc.contributor.authorKaya, Yunus
dc.contributor.authorOzturk, Hamdullah
dc.contributor.authorIzginli, Mucahit
dc.contributor.authorOztas, Taskin
dc.contributor.authorAslan, Nevzat
dc.contributor.authorErtugrul, Mehmet
dc.contributor.authorBarroso, Joaquim J.
dc.contributor.authorRamahi, Omar M.
dc.date.accessioned2026-10-29T19:08:50.742561811Z
dc.date.available2026-10-29T19:08:50.742561811Z
dc.date.issued2023
dc.description.abstractMicrowave techniques, as an indirect approach, can be applied for analyzing water content in honey by way of permittivity measurements. However, these techniques require proper calibration to accurately perform such indirect evaluation. Improper calibration standards used in this calibration process could naturally result in a reduction in the accuracy and thus the performance of dielectric characterization using microwaves. Self-calibrating microwave techniques can reduce the effects of imprecise standards and thus improve the performance of microwave measurements by bypassing the requirement of calibration standards. In this study, we develop a self-calibrating microwave measurement technique to determine the relative permittivity of honey samples and implement binary mixing models to predict adulteration levels of water-adulterated honey. From this implementation, it is observed that the parallel-capacitance mixing model could efficiently be applied to determine the concentration of water adulteration by examining the differences between absolute values of the real parts of the measured and predicted complex permittivities of adulterated honey.
dc.identifier.doi10.1109/tmtt.2022.3208024
dc.identifier.eissn1557-9670
dc.identifier.endpage697
dc.identifier.issn0018-9480
dc.identifier.issue2
dc.identifier.scopus2-s2.0-85139474583
dc.identifier.startpage691
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/bayburt/11824
dc.identifier.volume71
dc.identifier.wosWOS:000865089700001
dc.language.isoen
dc.publisherInstitute of Electrical and Electronics Engineers Inc.
dc.relation.ispartofIEEE Transactions on Microwave Theory and Techniques
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.subjectAdulteration
dc.subjectbinary mixing models
dc.subjecthoney
dc.subjectmicrowave techniques
dc.subjectself-calibration
dc.subjectwater content analysis
dc.subject.classificationEngineering, Electrical & Electronic
dc.subject.classificationTelecommunications
dc.subject.classificationEngineering
dc.subject.otherFood products
dc.subject.otherMicrowave measurement
dc.subject.otherMicrowaves
dc.subject.otherMixing
dc.subject.otherPermittivity
dc.subject.otherPermittivity measurement
dc.subject.otherTime measurement
dc.subject.otherAdulteration
dc.subject.otherBinary mixing
dc.subject.otherBinary mixing model
dc.subject.otherContent analysis
dc.subject.otherElectromagnetic waveguides
dc.subject.otherHoney
dc.subject.otherMicrowave technique
dc.subject.otherMicrowave theory and techniques
dc.subject.otherMixing modelling
dc.subject.otherSelf calibration
dc.subject.otherWater content analyse
dc.subject.otherCalibration
dc.titleHoney-Water Content Analysis by Mixing Models Using a Self-Calibrating Microwave Method
dc.typeArticle
rdl.citation.openalex18
rdl.citation.scopus18
rdl.citation.wos16
rdl.oa.statusclosed
rdl.scopus.quartileQ1
rdl.source.indexSCOPUS
rdl.source.indexWOS
rdl.wos.indexScience Citation Index Expanded (SCI-EXPANDED)