Sürdürülebilir Kalkınma Amaçları
Yazarlar
Yayınlar
- MakaleAçık Erişim2023Scopus SJRQ2Investigation of organic and inorganic matters removal from tannery wastewater using iron plate electrode by electrocoagulation process
Bingül, Züleyha; Irdemez, Şahset; Kul, Sinan; Ekmekyapar Torun, Fatma; Demircioğlu, Nuhi
In this study, COD, turbidity, total nitrogen, phosphate, sulphate, oil-grease and chromium removals from wastewaters taken from a local tannery using the electrocoagulation process were examined and the most suitable parameters for the electrocoagulation system were tried to be determined. Soluble iron plate electrodes were used as electrodes in the experiments. As a result of the studies carried out, the most suitable initial pH in uncontrolled pH was determined as pH = 4 and for controlled pH as pH = 5. In studies, the most suitable current density for iron electrodes was determined as 1.2 mA cm−2. Even if the increase in current density increased the amount of dissolved Fe, it negatively affected the removal efficiency. In addition, the turbidity of the wastewater was removed in 30 minutes, phosphate in 20 minutes and chromium in 15 minutes by 100%. During 60 minutes of operation, while 62.91% of TN, 87.8% of oil-grease were removed, sulphate was removed at the rate of 54.78%. In the studies, 1st and 2nd order kinetic equations for COD removal were examined and it was determined that removal kinetic is more suitable for 2nd order kinetics.
AtıfScopus7WoS4İncele
- MakaleAçık Erişim2022Investigation of the effect of current density and PH on oil and grease removal from leather industry wastewaters by electrocoagulation method
Bi̇Ngül Reçber, Züleyha; Ekmekyapar Torun, Fatma; Kul, Sinan; İRdemez, Şahset
In this study, the effects of pH and current density on the removal of high concentrations of oil and grease in leather industry wastewater by the electrocoagulation method were investigated. Two different types of electrodes were used in the study. Studies with aluminum electrodes have shown that these electrodes are more effective than iron electrodes in removing oil and grease. In addition, aluminum electrodes are affected more by the system pH than iron electrodes. Studies have shown that higher oil and grease removal efficiencies are obtained below pH 4 for both electrodes. While the oil and grease removal efficiency with Al electrodes is 95% at pH 2, this value decreases to 83% at pH 6. In Fe electrodes, while the removal efficiency is 87.83% at pH 2, it decreases to 83% at pH 6. The effect of current density on oil and grease removal was examined and it was observed that the removal efficiency remained constant above a certain current density in aluminum electrodes. While the efficiency of Al electrodes is 83.31% at 0.6 mA cm-2 current density, this value has increased to about 98% at 1.2, 1.8, and 2.4 mA cm-2 current densities. In Fe electrodes, the oil and grease removal efficiency is 82.66% at 0.6 mA cm-2 current density, while it is 90% at 1.2 and 1.8 mA cm-2 current densities and 98% at 2.4 mA cm-2. These results show that the electrocoagulation process removes the oil and grease in wastewater at a high rate. This shows that this process can also be used as pre-treatment before the biological treatment of industrial wastewater with high oil and grease content. Copyright 2021, Yıldız Technical University.
AtıfScopus2WoS2OpenAlex1İncele


