Sürdürülebilir Kalkınma Amaçları
Yazarlar
Yayınlar
- MakaleAçık Erişim2026Scopus SJRQ1A comparative study of metaheuristic algorithms for thermoeconomic optimization of an Organic Rankine Cycle
Tayfur, Bilal; Turhal, Uğur; Tozlu, Alperen
The efficient recovery of waste heat from biogas power plants via Organic Rankine Cycles (ORC) is essential for sustainable energy but requires satisfying conflicting thermodynamic and economic objectives. This study addresses the need for robust optimization strategies by evaluating nine recent metaheuristic algorithms to identify the most effective methods for maximizing net power while minimizing system costs. A multi-objective thermoeconomic model utilizing the specific exergy costing method was developed for a toluene-based ORC and optimized using algorithms including Dung Beetle, Snake, and NSGA-II. The optimization reduced the unit electricity cost by 9.1% (from $0.088/kWh to $0.080/kWh), with the Dung Beetle algorithm exhibiting superior convergence (Hypervolume 25.90) and the Snake algorithm demonstrating the best solution uniformity (Spread 1.54) with computational speed (0.084 s). These findings underscore that selecting algorithms based on specific exploration-exploitation characteristics is critical for achieving cost-effective and thermodynamically efficient power generation designs.
AtıfOpenAlex2İncele
- Derleme MakaleAçık Erişim2026Environmental and economic analysis of industrial waste heat recovery with hybrid heat pump application
Kazici, Halil İbrahim; Tozlu, Alperen
Today, increasing energy demands and environmental concerns have made energy efficiency a necessity from both economic and ecological perspectives. High energy consumption in industrial facilities increases costs and raises CO2 emissions. Therefore, waste heat recovery and the use of renewable energy are among the fundamental goals of sustainable production. Energy efficiency is important not only for reducing consumption but also for lowering greenhouse gas emissions, protecting the environment, and strengthening the economics of the business. In this context, heat pump technologies, which extract energy from low-temperature sources and make it reusable, stand out as effective, environmentally friendly, and efficient systems in both heating and cooling applications. In this study, waste heat from a cooling tower generated during the production process in an industrial facility was recovered through a water-source heat pump and integrated into the facility's heating system. The heat pump increased the heat energy by using low-temperature water and reused it in the process. During periods when the waste heat was insufficient, the system was supported by natural gas boilers, thus creating a hybrid operating model between the heat pump and the boiler. As a result of the implementation, natural gas consumption and electricity usage were significantly reduced, leading to lower energy costs and a substantial decrease in CO2 emissions, thereby providing notable environmental benefits. The findings indicate that the proposed system achieves an annual natural gas saving of 6,788,251 kWh and a net financial gain of 5,703,864 TL. Additionally, the payback period of the investment is calculated as 2.41 years, demonstrating the economic feasibility of the system. Overall, this case study highlights that the widespread adoption of hybrid heat pump systems in the industrial sector can make significant contributions to Türkiye’s energy transition and carbon emission goals.
- MakaleAçık Erişim2025Scopus SJRQ1Energy, exergy and economic optimization application of integrated dual-loop organic rankine cycle: A case of shopping mall power plant
Topcu, Muhammed Taha; Tozlu, Alperen; Bilen, Kadir
This paper presents a thermoeconomic analysis of the Dual-Loop Organic Rankine Cycle (DORC) integrated into the Erzurum Mall Power Plant (EMPP). The DORC system is designed to utilize waste heat at 425 degrees C and 9 kg/s, producing additional power for the existing plant. The integration of dual-loop ORC systems with different critical temperature fluids into an operational facility is analyzed. High-temperature cycles use working fluids such as Toluene, MDM (octamethylcyclotrisiloxane), n-Nonane, and n-Octane, while refrigerants R236fa, R600a, and R124 are employed in the low-temperature cycles. The designed model demonstrates that up to 11.4 % of the plant's existing capacity can be added as extra power. The Toluene/R600a combination is identified as the best fluid pair, delivering the highest total net power output (653.4 kW), the lowest total cost rate (19.18 $/h), and the highest exergy efficiency (20.18 %). Optimization of the DORC system is performed using the NSGA-II in MATLAB. For the toluene/R600a pair, the optimization results show an increase of 13.52 % in the net power output and decrease of 1.48 % in the total cost rate, which is a significant improvement over the initial results.
AtıfWoS3OpenAlex1İncele
- MakaleAçık Erişim2022Scopus SJRQ1Thermoeconomic analysis of a low-temperature waste-energy assisted power and hydrogen plant at off-NG grid region
Tozlu, Alperen; Kayabasi, Erhan; Ozcan, Hasan
In this study, thermoeconomic analysis of a CO2 power cycle and PEM hydrogen system using ultra-low temperature waste heat from a milk production facility is conducted. In the transcritical CO2 cycle, low-temperature LNG evaporation is used for cooling the condenser to increase the temperature difference enabling low temperature waste heat use. In addition, a PEM electrolyzer produces hydrogen to reduce the LNG requirement at the plant. A CO2-water exchanger has been designed to recover the pasteurized water's excess heat and evaporate the CO2 using Simcenter-Flomaster software. The inlet mass flow rates and outlet temperatures of the heat exchanger were optimized by performing thermoecomic analysis, and the thermal and economic performance of the facility was examined. The power cycle has 14% higher efficiency when LNG is used as the heat sink compared to ambient temperature condensation with an electricity production cost range at 0.05–0.11 $/kWh, and the hydrogen generation cost is between $2.6–5.20 kg−1. It is found that the plant could only be economically feasible when less than 50% of the power produced is used for hydrogen generation. Consequently, the proposed system can co-generate power and on-demand hydrogen in off-NG grid regions with reasonable investment and product costs.
AtıfScopus6WoS6OpenAlex8İncele
- MakaleYalnız künye2020Scopus SJRQ1Optimization of an adapted Kalina cycle to an actual municipal solid waste power plant by using NSGA-II method
Özahi, Emrah; Tozlu, Alperen
In this paper thermodynamic and thermoeconomic analyses and even optimization of a Kalina cycle (KC) which is adapted to an actual solid waste power plant with a 5.66 MW installed capacity are presented as an alternative solution which is utilized to produce additional power from the exhaust gas of the plant. Up to now there is almost no study related with an adapted KC to a typical municipal solid waste power plant, and also no study based on an optimization, thermodynamic and thermoeconomic analyses of such a system together. All these facts show the novelty of this study. Herein the waste heat with a temperature of 566 °C is utilized by the adapted KC. According to the analyses of the first and second law of thermodynamics on the system, it is deduced that the electricity of 954.6 kW can be produced with the exergy efficiency of 24.15%. Furthermore, this power production can be improved by using non-dominated sorting genetic algorithm method (NSGA-II) in MATLAB software program. According to the optimization study, the deviations of the net power output and the total cost rate are found to be +3.62% and −1.47 $/h, respectively for the cycle.
AtıfScopus45WoS36OpenAlex49İncele
- MakaleAçık Erişim2018Scopus SJRQ1Thermoeconomic multi-objective optimization of an organic Rankine cycle (ORC) adapted to an existing solid waste power plant
Özahi, Emrah; Tozlu, Alperen; Abuşoğlu, Ayşegül
In this paper, thermodynamic and thermoeconomic analyses, and also optimization of an organic Rankine cycle (ORC) were performed. The system was adapted to an existing solid waste power plant with a 5.66 MW installed power capacity in order to produce additional power from the exhaust gas. The actual operating data of the plant were utilized during all stages of the analyses. The originality of this paper is based on the analysis of the possibility of the energy conversion of an exhaust gas with a temperature of 566 & #x000B0;C into the electricity by utilizing an ORC system in the concept of waste-to-energy. Four different working fluids: toluene, octamethyltrisiloxane (MDM), octamethyl cyclotetrasiloxane (D4) and n-decane were considered and analyzed for the current system. This is also another novelty of this study due to lack of such a study, in the open literature, that deals with an ORC utilized for a typical municipal solid waste power plant. According to the thermoeconomic analyses, toluene was found to be the optimum working fluid with the maximum power output of 584.6 kW and the exergy efficiency of 15.69%. The optimization of the cycle was performed by using the non-dominated sorting genetic algorithm method (NSGA-II) in MATLAB software environment. The optimization results were compared and the deviations of the net power output and the total cost rate were evaluated as & #x2212;5.89%, & #x2212;3.51 & #x00024;/h for toluene; 0.96%, & #x2212;3.60 & #x00024;/h for MDM; 8.45%, & #x2212;2.04 & #x00024;/h for D4 and 2.00%, & #x2212;5.54 & #x00024;/h for n-decane, respectively.
AtıfScopus87WoS80OpenAlex88İncele
- MakaleYalnız künye2017Scopus SJRQ1Toward cost-effective and energy-efficient heat recovery systems in buildings: Thermal performance monitoring
Cuce, Pinar Mert; Cuce, Erdem
Recent studies show that it is possible to reduce heating or cooling demand of a building as using heat recovery systems. Heat recovery technology is basically utilised to mitigate the heat loss, and hence energy consumption due to HVAC. Within the scope of this study, thermal comfort analyses of a test house integrated with a novel polycarbonate heat exchanger are conducted. At pre and post-retrofit case, temperature, relative humidity and CO2 measurements are carried out for a test period of one week. The results indicate that the internal CO2 concentration is not at desirable range due to lack of ventilation in the test house at the pre-retrofit case. However, following the integration of the novel ventilation system into the test house, CO2 concentration is found to be varying notably from 350 to 400 ppm which corresponds to the actual comfort conditions for indoor environments. It is also concluded from the results that the average relative humidity inside the test house at the post-retrofit case is found to be 57%, which is in the desired range whereas it is considerably high before retrofitting.
AtıfScopus26WoS25OpenAlex33İncele
- MakaleAçık Erişim2016Scopus SJRQ1A novel roof type heat recovery panel for low-carbon buildings: An experimental investigation
Cuce, Pinar Mert; Cuce, Erdem; Riffat, Saffa
Energy saving and its efficient utilization is of prime interest in today's world due to the limited energy resources and growing significance of environmental issues. Despite the intensive efforts to narrow the gap between conventional energy sources (wood, coal, gas, oil, etc.) and renewables, renewable energy resources currently supply only about 14% of total world energy demand. In this regard, energy management and optimization are considered compulsory as much as the clean energy generation. Recent works indicate that the buildings play a significant role on global energy consumption. They are responsible for about 40% of global energy demand. Among the different building types, domestic buildings have the largest share with 63% and most of energy is utilized for heating, ventilation and air conditioning (HVAC) systems in those buildings. Energy consumption levels of buildings can be notably reduced through waste heat recovery in HVAC systems. There are several attempts in literature addressing the possibility of decreasing energy consumption of buildings via waste heat recovery technologies. The heat recovery technologies are cost effective and user friendly applications. The use of heat recovery systems aims at mitigating the energy consumption for HVAC applications as well as the greenhouse gas emissions, and hence decreasing the adverse effects of global warming on the Earth. It is well-documented in literature that the heat recovery systems are very promising for domestic applications. In this paper, experimental results of a novel heat recovery system developed for low-carbon buildings are presented. The proposed heat recovery system consists of a plate-type heat exchanger, blower fans and ducts. The parallel-flow arrangement is used to run the system. The system is designed as under roof application. The aim of the system is to recover waste heat and to preheat fresh air using stale air. The experiments of the system are carried out in winter season in Kent, UK. The study aims to investigate the coefficient of performance (COP) of the system as well as the heat recovery efficiency. The results show that the heat recovery efficiency of the proposed system is around 89% while the COP is 4.5. The proposed system can be used in both winter and summer conditions without requiring additional work. Its labor cost is extremely low, so it is cost-effective and user friendly.
AtıfScopus28WoS23OpenAlex31İncele






