Energy, exergy and economic optimization application of integrated dual-loop organic rankine cycle: A case of shopping mall power plant
Özet
This paper presents a thermoeconomic analysis of the Dual-Loop Organic Rankine Cycle (DORC) integrated into the Erzurum Mall Power Plant (EMPP). The DORC system is designed to utilize waste heat at 425 degrees C and 9 kg/s, producing additional power for the existing plant. The integration of dual-loop ORC systems with different critical temperature fluids into an operational facility is analyzed. High-temperature cycles use working fluids such as Toluene, MDM (octamethylcyclotrisiloxane), n-Nonane, and n-Octane, while refrigerants R236fa, R600a, and R124 are employed in the low-temperature cycles. The designed model demonstrates that up to 11.4 % of the plant's existing capacity can be added as extra power. The Toluene/R600a combination is identified as the best fluid pair, delivering the highest total net power output (653.4 kW), the lowest total cost rate (19.18 $/h), and the highest exergy efficiency (20.18 %). Optimization of the DORC system is performed using the NSGA-II in MATLAB. For the toluene/R600a pair, the optimization results show an increase of 13.52 % in the net power output and decrease of 1.48 % in the total cost rate, which is a significant improvement over the initial results.
Anahtar Kelimeler
- WoS
- 3
- OpenAlex
- 1
Tam Kayıt
| Alan | Değer | Dil |
|---|---|---|
| dc.contributor.author | Topcu, Muhammed Taha | |
| dc.contributor.author | Tozlu, Alperen | |
| dc.contributor.author | Bilen, Kadir | |
| dc.date.accessioned | 2026-10-29T19:15:45.327310050Z | |
| dc.date.available | 2026-10-29T19:15:45.327310050Z | |
| dc.date.issued | 2025-10 | |
| dc.description.abstract | This paper presents a thermoeconomic analysis of the Dual-Loop Organic Rankine Cycle (DORC) integrated into the Erzurum Mall Power Plant (EMPP). The DORC system is designed to utilize waste heat at 425 degrees C and 9 kg/s, producing additional power for the existing plant. The integration of dual-loop ORC systems with different critical temperature fluids into an operational facility is analyzed. High-temperature cycles use working fluids such as Toluene, MDM (octamethylcyclotrisiloxane), n-Nonane, and n-Octane, while refrigerants R236fa, R600a, and R124 are employed in the low-temperature cycles. The designed model demonstrates that up to 11.4 % of the plant's existing capacity can be added as extra power. The Toluene/R600a combination is identified as the best fluid pair, delivering the highest total net power output (653.4 kW), the lowest total cost rate (19.18 $/h), and the highest exergy efficiency (20.18 %). Optimization of the DORC system is performed using the NSGA-II in MATLAB. For the toluene/R600a pair, the optimization results show an increase of 13.52 % in the net power output and decrease of 1.48 % in the total cost rate, which is a significant improvement over the initial results. | |
| dc.description.sponsorship | Ataturk University Coordination Unit of Scientific Research Projects [FDK-2022-10614] | |
| dc.identifier.articlenumber | 106762 | |
| dc.identifier.doi | 10.1016/j.csite.2025.106762 | |
| dc.identifier.issn | 2214-157X | |
| dc.identifier.uri | https://rdlopen.rawdatalibrary.net/r/bayburt/14346 | |
| dc.identifier.volume | 74 | |
| dc.identifier.wos | WOS:001550882600002 | |
| dc.language.iso | en | |
| dc.publisher | ELSEVIER | |
| dc.relation.ispartof | CASE STUDIES IN THERMAL ENGINEERING | |
| dc.rights | info:eu-repo/semantics/openAccess | |
| dc.subject | Waste heat recovery | |
| dc.subject | Working fluid pairs | |
| dc.subject | Thermoeconomics | |
| dc.subject | Dual-loop organic rank & imath | |
| dc.subject | ne cycle | |
| dc.subject | Genetic algorithm | |
| dc.subject | Optimization | |
| dc.subject.classification | Thermodynamics | |
| dc.subject.other | WASTE HEAT-RECOVERY | |
| dc.subject.other | WORKING FLUID ANALYSIS | |
| dc.subject.other | ORC SYSTEM | |
| dc.subject.other | MULTIOBJECTIVE OPTIMIZATION | |
| dc.subject.other | DIESEL-ENGINE | |
| dc.subject.other | PERFORMANCE ANALYSIS | |
| dc.subject.other | PARAMETRIC ANALYSIS | |
| dc.subject.other | SELECTION | |
| dc.subject.other | GT | |
| dc.title | Energy, exergy and economic optimization application of integrated dual-loop organic rankine cycle: A case of shopping mall power plant | |
| dc.type | Article | |
| rdl.citation.openalex | 1 | |
| rdl.citation.wos | 3 | |
| rdl.oa.status | gold | |
| rdl.oa.url | https://doi.org/10.1016/j.csite.2025.106762 | |
| rdl.scopus.quartile | Q1 | |
| rdl.sdg | SDG07 | |
| rdl.sdg | SDG12 | |
| rdl.sdg | SDG09 | |
| rdl.source.index | WOS | |
| rdl.wos.index | Science Citation Index Expanded (SCI-EXPANDED) |