Energy, exergy and economic optimization application of integrated dual-loop organic rankine cycle: A case of shopping mall power plant

MakaleAçık ErişimScopus SJRQ1
  • SDG 7 · Erişilebilir ve Temiz Enerji
  • SDG 9 · Sanayi, Yenilikçilik ve Altyapı
  • SDG 12 · Sorumlu Üretim ve Tüketim

Özet

This paper presents a thermoeconomic analysis of the Dual-Loop Organic Rankine Cycle (DORC) integrated into the Erzurum Mall Power Plant (EMPP). The DORC system is designed to utilize waste heat at 425 degrees C and 9 kg/s, producing additional power for the existing plant. The integration of dual-loop ORC systems with different critical temperature fluids into an operational facility is analyzed. High-temperature cycles use working fluids such as Toluene, MDM (octamethylcyclotrisiloxane), n-Nonane, and n-Octane, while refrigerants R236fa, R600a, and R124 are employed in the low-temperature cycles. The designed model demonstrates that up to 11.4 % of the plant's existing capacity can be added as extra power. The Toluene/R600a combination is identified as the best fluid pair, delivering the highest total net power output (653.4 kW), the lowest total cost rate (19.18 $/h), and the highest exergy efficiency (20.18 %). Optimization of the DORC system is performed using the NSGA-II in MATLAB. For the toluene/R600a pair, the optimization results show an increase of 13.52 % in the net power output and decrease of 1.48 % in the total cost rate, which is a significant improvement over the initial results.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/bayburt/14346Resmi atıflarda kullanılan kalıcı adres
DOI
https://doi.org/10.1016/j.csite.2025.106762Yayıncı resmi DOI adresi
İndeks kayıtları
Kaydın indeks veri tabanlarındaki sayfası (aktarımda alınan kayıt numarasıyla). Erişim, indeksin kendi koşullarına bağlıdır.
Atıflar
WoS
3
OpenAlex
1
Her kaynağın kendi saydığı toplam atıf; aktarım ve zenginleştirme sırasında alındı.
Tam Kayıt
AlanDeğerDil
dc.contributor.authorTopcu, Muhammed Taha
dc.contributor.authorTozlu, Alperen
dc.contributor.authorBilen, Kadir
dc.date.accessioned2026-10-29T19:15:45.327310050Z
dc.date.available2026-10-29T19:15:45.327310050Z
dc.date.issued2025-10
dc.description.abstractThis paper presents a thermoeconomic analysis of the Dual-Loop Organic Rankine Cycle (DORC) integrated into the Erzurum Mall Power Plant (EMPP). The DORC system is designed to utilize waste heat at 425 degrees C and 9 kg/s, producing additional power for the existing plant. The integration of dual-loop ORC systems with different critical temperature fluids into an operational facility is analyzed. High-temperature cycles use working fluids such as Toluene, MDM (octamethylcyclotrisiloxane), n-Nonane, and n-Octane, while refrigerants R236fa, R600a, and R124 are employed in the low-temperature cycles. The designed model demonstrates that up to 11.4 % of the plant's existing capacity can be added as extra power. The Toluene/R600a combination is identified as the best fluid pair, delivering the highest total net power output (653.4 kW), the lowest total cost rate (19.18 $/h), and the highest exergy efficiency (20.18 %). Optimization of the DORC system is performed using the NSGA-II in MATLAB. For the toluene/R600a pair, the optimization results show an increase of 13.52 % in the net power output and decrease of 1.48 % in the total cost rate, which is a significant improvement over the initial results.
dc.description.sponsorshipAtaturk University Coordination Unit of Scientific Research Projects [FDK-2022-10614]
dc.identifier.articlenumber106762
dc.identifier.doi10.1016/j.csite.2025.106762
dc.identifier.issn2214-157X
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/bayburt/14346
dc.identifier.volume74
dc.identifier.wosWOS:001550882600002
dc.language.isoen
dc.publisherELSEVIER
dc.relation.ispartofCASE STUDIES IN THERMAL ENGINEERING
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectWaste heat recovery
dc.subjectWorking fluid pairs
dc.subjectThermoeconomics
dc.subjectDual-loop organic rank & imath
dc.subjectne cycle
dc.subjectGenetic algorithm
dc.subjectOptimization
dc.subject.classificationThermodynamics
dc.subject.otherWASTE HEAT-RECOVERY
dc.subject.otherWORKING FLUID ANALYSIS
dc.subject.otherORC SYSTEM
dc.subject.otherMULTIOBJECTIVE OPTIMIZATION
dc.subject.otherDIESEL-ENGINE
dc.subject.otherPERFORMANCE ANALYSIS
dc.subject.otherPARAMETRIC ANALYSIS
dc.subject.otherSELECTION
dc.subject.otherGT
dc.titleEnergy, exergy and economic optimization application of integrated dual-loop organic rankine cycle: A case of shopping mall power plant
dc.typeArticle
rdl.citation.openalex1
rdl.citation.wos3
rdl.oa.statusgold
rdl.oa.urlhttps://doi.org/10.1016/j.csite.2025.106762
rdl.scopus.quartileQ1
rdl.sdgSDG07
rdl.sdgSDG12
rdl.sdgSDG09
rdl.source.indexWOS
rdl.wos.indexScience Citation Index Expanded (SCI-EXPANDED)