Toward cost-effective and energy-efficient heat recovery systems in buildings: Thermal performance monitoring

MakaleYalnız künyeScopus SJRQ1
  • SDG 7 · Erişilebilir ve Temiz Enerji
  • SDG 11 · Sürdürülebilir Şehirler ve Topluluklar
  • SDG 13 · İklim Eylemi

Özet

Recent studies show that it is possible to reduce heating or cooling demand of a building as using heat recovery systems. Heat recovery technology is basically utilised to mitigate the heat loss, and hence energy consumption due to HVAC. Within the scope of this study, thermal comfort analyses of a test house integrated with a novel polycarbonate heat exchanger are conducted. At pre and post-retrofit case, temperature, relative humidity and CO2 measurements are carried out for a test period of one week. The results indicate that the internal CO2 concentration is not at desirable range due to lack of ventilation in the test house at the pre-retrofit case. However, following the integration of the novel ventilation system into the test house, CO2 concentration is found to be varying notably from 350 to 400 ppm which corresponds to the actual comfort conditions for indoor environments. It is also concluded from the results that the average relative humidity inside the test house at the post-retrofit case is found to be 57%, which is in the desired range whereas it is considerably high before retrofitting.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/bayburt/13792Resmi atıflarda kullanılan kalıcı adres
İndeks kayıtları
Kaydın indeks veri tabanlarındaki sayfası (aktarımda alınan kayıt numarasıyla). Erişim, indeksin kendi koşullarına bağlıdır.
Atıflar
Scopus
26
WoS
25
OpenAlex
33
Her kaynağın kendi saydığı toplam atıf; aktarım ve zenginleştirme sırasında alındı.
Tam Kayıt
AlanDeğerDil
dc.contributor.authorCuce, Pinar Mert
dc.contributor.authorCuce, Erdem
dc.date.accessioned2026-10-29T19:11:27.951804510Z
dc.date.available2026-10-29T19:11:27.951804510Z
dc.date.issued2017
dc.description.abstractRecent studies show that it is possible to reduce heating or cooling demand of a building as using heat recovery systems. Heat recovery technology is basically utilised to mitigate the heat loss, and hence energy consumption due to HVAC. Within the scope of this study, thermal comfort analyses of a test house integrated with a novel polycarbonate heat exchanger are conducted. At pre and post-retrofit case, temperature, relative humidity and CO2 measurements are carried out for a test period of one week. The results indicate that the internal CO2 concentration is not at desirable range due to lack of ventilation in the test house at the pre-retrofit case. However, following the integration of the novel ventilation system into the test house, CO2 concentration is found to be varying notably from 350 to 400 ppm which corresponds to the actual comfort conditions for indoor environments. It is also concluded from the results that the average relative humidity inside the test house at the post-retrofit case is found to be 57%, which is in the desired range whereas it is considerably high before retrofitting.
dc.description.sponsorshipEU Commission [314283]
dc.description.sponsorshipIZO-CAM A.S.
dc.identifier.doi10.1016/j.energy.2017.02.159
dc.identifier.eissn1873-6785
dc.identifier.endpage494
dc.identifier.issn0360-5442
dc.identifier.scopus2-s2.0-85016004576
dc.identifier.startpage487
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/bayburt/13792
dc.identifier.volume137
dc.identifier.wosWOS:000414879400044
dc.language.isoen
dc.publisherElsevier Ltd
dc.relation.conference15th International Conference on Sustainable Energy Technologies (SET)
dc.relation.ispartofEnergy
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.subjectHeat exchanger
dc.subjectHVAC
dc.subjectPolycarbonate
dc.subjectResidential buildings
dc.subjectWaste heat recovery
dc.subject.classificationThermodynamics
dc.subject.classificationEnergy & Fuels
dc.subject.otherAir conditioning
dc.subject.otherAtmospheric composition
dc.subject.otherCarbon dioxide
dc.subject.otherCooling systems
dc.subject.otherCost effectiveness
dc.subject.otherEnergy efficiency
dc.subject.otherEnergy utilization
dc.subject.otherHeat exchangers
dc.subject.otherHouses
dc.subject.otherPolycarbonates
dc.subject.otherRetrofitting
dc.subject.otherVentilation
dc.subject.otherWaste heat
dc.subject.otherWaste heat utilization
dc.subject.otherHeat recovery systems
dc.subject.otherHVAC
dc.subject.otherIndoor environment
dc.subject.otherRecovery technology
dc.subject.otherResidential building
dc.subject.otherThermal comfort analysis
dc.subject.otherThermal Performance
dc.subject.otherVentilation systems
dc.subject.otherbuilding
dc.subject.othercost analysis
dc.subject.otherheat source
dc.subject.otherinstrumentation
dc.subject.othermonitoring
dc.subject.otherperformance assessment
dc.subject.otherrecovery
dc.subject.otherrelative humidity
dc.subject.othertechnology
dc.subject.otherwaste
dc.subject.otherHeating
dc.titleToward cost-effective and energy-efficient heat recovery systems in buildings: Thermal performance monitoring
dc.typeArticle
rdl.citation.openalex33
rdl.citation.scopus26
rdl.citation.wos25
rdl.conference.dateJUL 19-22, 2016
rdl.conference.placeNatl Univ Singapore, Singapore, SINGAPORE
rdl.oa.statusclosed
rdl.scopus.quartileQ1
rdl.sdgSDG13
rdl.sdgSDG07
rdl.sdgSDG11
rdl.source.indexSCOPUS
rdl.source.indexWOS
rdl.wos.indexScience Citation Index Expanded (SCI-EXPANDED)
rdl.wos.indexConference Proceedings Citation Index - Science (CPCI-S)