- MakaleAçık Erişim2024Scopus SJRQ3Thermoeconomic Analyses of Heat Pumps
Öztekin, Erman Kadir; Gür, Mehmet Murat; Karaali, Rabi
Recently, the rapid development of technology and the increase in energy costs and needs have made reducing the costs and efficient use of energy and exergy important. The thermoeconomic analysis method, which is the best cost analysis method of energy and exergy, gives the ways to reduce costs and increase efficiency that can be applied a facility. It has been found that the most suitable thermoeconomic solution for winter heating and summer cooling of a facility is a vertical underground source heat pump and the most high-performance working fluid that should be used is R32. If the heating is done with a ground source heat pump instead of electrical energy, 4.25 kW of heating energy will be obtained for each kW of electrical energy given for heating, since the costs are COPIP 4.25. Here the earnings increase by around 325%. In other words, heating costs decrease by around 77.5 percent, that is, from one hundred liras to 22. 5 liras.
AtıfOpenAlex4İncele
- MakaleAçık Erişim2016Scopus SJRQ1Exergetic interrelation between an heat pump and components
Çakır, Uğur; Çomaklı, Kemal
In this study, the relation between the exergetic performance of the heat pump and its components are investigated experimentally by using an air to water heat pump. Moreover, the effects of the working conditions of the components on the exergetic performance of the system are exposed and discussed. An experimental air to water heat pump system was designed and built. The results were evaluated by comparing the components and heat pump according to their performances. 33–45% of the all destructed exergy of the heat pump system comes into existence in the compressor. The contribution of the condenser to the total exergy destruction rate of the heat pump is between 23% and 34%. Contribution of the compressor to the exergy destruction rate of heat pump decreases with an increase in the air temperature and it increases with a decrease in the air mass flow rate. Contribution of the compressor to the exergy destruction rate of heat pump decreases with an increase in the air temperature and it increases with a decrease in the air mass flow rate. In terms of exergetic performance of the heat pump, the importance and priority of the components vary with the heat source thermal conditions.
AtıfScopus15WoS14OpenAlex16İncele
- MakaleAçık Erişim2013Scopus SJRQ2Energetic and exergetic comparison of air to air and air to water heat pumps according to evaporator conditions
Çomakli, Kemal; Çakir, Uǧur; Şahin, Erol; Kuş, Ayşegül Çokgez
This paper presents an experimental energetic and exergetic comparison for a heat pump system that can be run in different modes as air to air and air to water. Components of the heat pump do not change when the running mode changes, except for the condenser. This means that some external and internal effects (like compressor type, pipe lines) that can affect the system performance will be the same for each running mode. The comparison which was made in this study demonstrates which system leads to an efficient conversion and supply of energy and exergy. In the analysis, four balance (mass, energy, entropy and exergy) equations are applied to the system for the two modes. Exergy and energy efficiency values for both systems are given, while exergy destructions in each of the systems are determined and presented. It is seen that the heat pump unit which has the highest COP value is the air to air type (3.45-3.8); second is the air to water type (3.35-3.41). The exergy efficiency of the air to air heat pump (29-32%) is higher than the exergy efficiency of the air to water type heat pump (24.1-25). Ranking of the exergy destruction rates of the two heat pump types from high to low is as follows: air to air and air to water.
AtıfScopus5OpenAlex5İncele
- MakaleYalnız künye2013Scopus SJRQ1An experimental exergetic comparison of four different heat pump systems working at same conditions: As air to air, air to water, water to water and water to air
Çakir, Uǧur; Çomakli, Kemal; Çomakli, Ömer; Karsli, Süleyman
In this study, we designed a multifunctional heat pump system using just one scroll compressor and which can be run in four different modes, namely air to air, air to water, water to water and water to air, in order to make an experimental energetic and exergetic performance comparison. Experimental system consists of two condensers and two evaporators and uses R22 as working fluid. One of the evaporators and condensers uses water and the others use air as heat source/sink. Heating capacities of four heat pump types are equal to each other. It is realized by adjusting the mass flow rate and temperature level of external fluid of condenser. Results show that the heat pump unit which has the maximum COP (coefficient of performance) value is water to air type with 3.94 and followed by water to water type with 3.73, air to air type with 3.54 and air to water type with 3.40. Ranking of four heat pump types with respect to their mean exergy efficiency is as follows; water to air type with 30.23%, air to air type with 30.22%, air to water type with 24.77% and water to water type with 24.01%. Exergy destruction rates of the systems were investigated in this study and the results revealed that the heat pump type which has the maximum exergy destruction is air to air type with 2.93kW. The second highest one is air to water type with 2.84kW. The third highest one is water to air type with 2.64kW and last one is water to water type with 2.55kW. It is understood that the temperature of the evaporator external fluid affects the exergetic efficiency of the system more than the mass flow rate. In contrast to the previous, the dominant parameter which has more important effect on the exergy destruction of the heat pump unit is the mass flow rate of evaporator external fluid.
AtıfScopus55WoS46İncele
- MakaleYalnız künye2010Scopus SJRQ3ANALYSIS OF HEAT PUMPS WITH ZEOTROPIC REFRIGERANT MIXTURES BY TAGUCHI METHOD
Comakli, Omer; Comakli, Kemal; Ozdemir, Nesrin; Yilmaz, Mehmet
The goal of this work is to determine the optimum set of parameters by using the Taguchi method in vapour compression heat pump systems. The experimental apparatus consist of an air-to-liquid vapor compression heat pump, a water cooled condenser, a forced air evaporator, an electrical air and water heaters, and various measuring elements and other auxiliary equipments. Refrigerants R22, R407C, and five of their binary mixtures which contain about 0%, 25%, 50%, 75%, and 100% mass fractions of R407C were tested. To determine the effect of the chosen parameters on the system and optimum working conditions, an experimental design method suggested by Genichi Taguchi was used. The most effective parameters are found to be the condenser water mass flow rate for the coefficient of performance and to be condenser water inlet temperature for the exergetic efficiency.
AtıfWoS6İncele