Sürdürülebilir Kalkınma Amaçları

  • MakaleAçık Erişim2020
    Voltage Control of Cuk Converter with PI and Fuzzy Logic Controller in Continuous Current Mode

    Çorapsız, Muhammed Reşit; Çorapsız, Muhammed Fatih; Yilmaz, Mehmet

    In today's energy systems, many equipment operates with Direct Current (DC) voltage. However, it is not always possible to obtain the voltage level required for the operation of these equipment from standard power supplies. For this reason, DC-DC converters are used to achieve the desired voltage values for equipment with different DC voltage levels. These converters are divided into three general categories, named Buck, Boost and Buck-Boost. The most preferred converter is the Cuk converter with low output ripple voltage, which can operate in both buck and boost modes. In this study, a detailed analysis of the Cuk converter, which is frequently used in Photovoltaic (PV) Panels was performed and different control methods of the output voltage were proposed. While performing this analysis, the dynamic model of the Cuk converter was created in which, Proportional-Integral (PI) and Fuzzy Logic (FL) are used to control the output voltage of the Cuk converter. The performances of both controllers were compared with respect to performance parameters such as steady state error, settling time and rise time. When the results obtained were evaluated as a whole, it was observed that FLC achieved the desired reference with less rise and settling time. In this study, modeling and controller applications of Cuk converter are realized by using MATLAB / SIMULINK program.

    • SDG 7 · Erişilebilir ve Temiz Enerji
    AtıfOpenAlex8
    TR Dizinİncele
  • MakaleYalnız künye2010Scopus SJRQ3
    ANALYSIS OF HEAT PUMPS WITH ZEOTROPIC REFRIGERANT MIXTURES BY TAGUCHI METHOD

    Comakli, Omer; Comakli, Kemal; Ozdemir, Nesrin; Yilmaz, Mehmet

    The goal of this work is to determine the optimum set of parameters by using the Taguchi method in vapour compression heat pump systems. The experimental apparatus consist of an air-to-liquid vapor compression heat pump, a water cooled condenser, a forced air evaporator, an electrical air and water heaters, and various measuring elements and other auxiliary equipments. Refrigerants R22, R407C, and five of their binary mixtures which contain about 0%, 25%, 50%, 75%, and 100% mass fractions of R407C were tested. To determine the effect of the chosen parameters on the system and optimum working conditions, an experimental design method suggested by Genichi Taguchi was used. The most effective parameters are found to be the condenser water mass flow rate for the coefficient of performance and to be condenser water inlet temperature for the exergetic efficiency.

    AtıfWoS6
    Web of Scienceİncele