ANALYSIS OF HEAT PUMPS WITH ZEOTROPIC REFRIGERANT MIXTURES BY TAGUCHI METHOD

MakaleYalnız künyeScopus SJRQ3

Özet

The goal of this work is to determine the optimum set of parameters by using the Taguchi method in vapour compression heat pump systems. The experimental apparatus consist of an air-to-liquid vapor compression heat pump, a water cooled condenser, a forced air evaporator, an electrical air and water heaters, and various measuring elements and other auxiliary equipments. Refrigerants R22, R407C, and five of their binary mixtures which contain about 0%, 25%, 50%, 75%, and 100% mass fractions of R407C were tested. To determine the effect of the chosen parameters on the system and optimum working conditions, an experimental design method suggested by Genichi Taguchi was used. The most effective parameters are found to be the condenser water mass flow rate for the coefficient of performance and to be condenser water inlet temperature for the exergetic efficiency.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/bayburt/14520Resmi atıflarda kullanılan kalıcı adres
İndeks kayıtları
Kaydın indeks veri tabanlarındaki sayfası (aktarımda alınan kayıt numarasıyla). Erişim, indeksin kendi koşullarına bağlıdır.
Atıflar
WoS
6
Her kaynağın kendi saydığı toplam atıf; aktarım ve zenginleştirme sırasında alındı.
Tam Kayıt
AlanDeğerDil
dc.contributor.authorComakli, Omer
dc.contributor.authorComakli, Kemal
dc.contributor.authorOzdemir, Nesrin
dc.contributor.authorYilmaz, Mehmet
dc.date.accessioned2026-10-29T19:15:58.531335784Z
dc.date.available2026-10-29T19:15:58.531335784Z
dc.date.issued2010
dc.description.abstractThe goal of this work is to determine the optimum set of parameters by using the Taguchi method in vapour compression heat pump systems. The experimental apparatus consist of an air-to-liquid vapor compression heat pump, a water cooled condenser, a forced air evaporator, an electrical air and water heaters, and various measuring elements and other auxiliary equipments. Refrigerants R22, R407C, and five of their binary mixtures which contain about 0%, 25%, 50%, 75%, and 100% mass fractions of R407C were tested. To determine the effect of the chosen parameters on the system and optimum working conditions, an experimental design method suggested by Genichi Taguchi was used. The most effective parameters are found to be the condenser water mass flow rate for the coefficient of performance and to be condenser water inlet temperature for the exergetic efficiency.
dc.description.sponsorshipAtaturk University, Research Project Foundation [BAP-2003/379, 2005/16]
dc.description.sponsorshipAtaturk University
dc.identifier.endpage122
dc.identifier.issn1300-3615
dc.identifier.issue2
dc.identifier.startpage113
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/bayburt/14520
dc.identifier.volume30
dc.identifier.wosWOS:000284139100012
dc.language.isoen
dc.publisherTURKISH SOC THERMAL SCIENCES TECHNOLOGY
dc.relation.ispartofISI BILIMI VE TEKNIGI DERGISI-JOURNAL OF THERMAL SCIENCE AND TECHNOLOGY
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.subjectHeat pump
dc.subjectR22
dc.subjectR407C Zeotropic mixture
dc.subjectTaguchi method
dc.subjectOptimum working conditions
dc.subject.classificationThermodynamics
dc.subject.classificationEngineering, Mechanical
dc.subject.classificationEngineering
dc.subject.otherOPTIMUM WORKING-CONDITIONS
dc.subject.otherVAPOR COMPRESSION PLANT
dc.subject.otherLINE QUALITY-CONTROL
dc.subject.otherR22
dc.subject.otherDESIGN
dc.subject.otherSYSTEMS
dc.subject.otherENERGY
dc.subject.otherR407C
dc.titleANALYSIS OF HEAT PUMPS WITH ZEOTROPIC REFRIGERANT MIXTURES BY TAGUCHI METHOD
dc.typeArticle
rdl.citation.wos6
rdl.oa.statusclosed
rdl.scopus.quartileQ3
rdl.source.indexWOS
rdl.wos.indexScience Citation Index Expanded (SCI-EXPANDED)