Energetic and exergetic comparison of air to air and air to water heat pumps according to evaporator conditions

MakaleAçık ErişimScopus SJRQ2
  • SDG 7 · Erişilebilir ve Temiz Enerji
  • SDG 13 · İklim Eylemi

Özet

This paper presents an experimental energetic and exergetic comparison for a heat pump system that can be run in different modes as air to air and air to water. Components of the heat pump do not change when the running mode changes, except for the condenser. This means that some external and internal effects (like compressor type, pipe lines) that can affect the system performance will be the same for each running mode. The comparison which was made in this study demonstrates which system leads to an efficient conversion and supply of energy and exergy. In the analysis, four balance (mass, energy, entropy and exergy) equations are applied to the system for the two modes. Exergy and energy efficiency values for both systems are given, while exergy destructions in each of the systems are determined and presented. It is seen that the heat pump unit which has the highest COP value is the air to air type (3.45-3.8); second is the air to water type (3.35-3.41). The exergy efficiency of the air to air heat pump (29-32%) is higher than the exergy efficiency of the air to water type heat pump (24.1-25). Ranking of the exergy destruction rates of the two heat pump types from high to low is as follows: air to air and air to water.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/bayburt/13659Resmi atıflarda kullanılan kalıcı adres
İndeks kayıtları
Kaydın indeks veri tabanlarındaki sayfası (aktarımda alınan kayıt numarasıyla). Erişim, indeksin kendi koşullarına bağlıdır.
Atıflar
Scopus
5
OpenAlex
5
Her kaynağın kendi saydığı toplam atıf; aktarım ve zenginleştirme sırasında alındı.
Tam Kayıt
AlanDeğerDil
dc.contributor.authorÇomakli, Kemal
dc.contributor.authorÇakir, Uǧur
dc.contributor.authorŞahin, Erol
dc.contributor.authorKuş, Ayşegül Çokgez
dc.date.accessioned2026-10-29T19:11:17.055775985Z
dc.date.available2026-10-29T19:11:17.055775985Z
dc.date.issued2013
dc.description.abstractThis paper presents an experimental energetic and exergetic comparison for a heat pump system that can be run in different modes as air to air and air to water. Components of the heat pump do not change when the running mode changes, except for the condenser. This means that some external and internal effects (like compressor type, pipe lines) that can affect the system performance will be the same for each running mode. The comparison which was made in this study demonstrates which system leads to an efficient conversion and supply of energy and exergy. In the analysis, four balance (mass, energy, entropy and exergy) equations are applied to the system for the two modes. Exergy and energy efficiency values for both systems are given, while exergy destructions in each of the systems are determined and presented. It is seen that the heat pump unit which has the highest COP value is the air to air type (3.45-3.8); second is the air to water type (3.35-3.41). The exergy efficiency of the air to air heat pump (29-32%) is higher than the exergy efficiency of the air to water type heat pump (24.1-25). Ranking of the exergy destruction rates of the two heat pump types from high to low is as follows: air to air and air to water.
dc.identifier.doi10.15282/ijame.8.2013.2.0090
dc.identifier.endpage1120
dc.identifier.issn2229-8649
dc.identifier.issue1
dc.identifier.scopus2-s2.0-84897031024
dc.identifier.startpage1108
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/bayburt/13659
dc.identifier.volume8
dc.language.isoen
dc.publisherUniversiti Malaysia Pahang
dc.relation.ispartofInternational Journal of Automotive and Mechanical Engineering
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectEnergy saving
dc.subjectExergy
dc.subjectHeat pump
dc.subjectHeat pump comparison
dc.titleEnergetic and exergetic comparison of air to air and air to water heat pumps according to evaporator conditions
dc.typeArticle
rdl.citation.openalex5
rdl.citation.scopus5
rdl.oa.statusgold
rdl.oa.urlhttps://doi.org/10.15282/ijame.8.2013.2.0090
rdl.scopus.quartileQ2
rdl.sdgSDG07
rdl.sdgSDG13
rdl.source.indexSCOPUS