Comparison of phenol removal with ozonation in jet loop reactor and bubble column

MakaleYalnız künyeScopus SJRQ1
  • SDG 6 · Temiz Su ve Sanitasyon
  • SDG 12 · Sorumlu Üretim ve Tüketim

Özet

This study aimed to remove phenol with ozonation in a jet loop reactor (JLR) and a bubble column (BC). In the first stage of the study, the mass transfer properties of JLR were determined and superiority over BC reactors were shown, and in the second stage, these reactors were used in phenol removal studies. At the same conditions, the volumetric mass transfer coefficient of JLR was 0.540 min-1, while this value was determined as 0.246 min-1 in the BC reactor. In phenol removal, the effects of initial phenol concentration, ozone dosage and pH on phenol and chemical oxygen demand (COD) removal were determined for both JLR and BC. While the pseudo-first rate constant for phenol removal in JLR at 221 mg/min ozone dosage was 0.1756 min-1, this value was only calculated as 0.1157 min-1 in the BC reactor. As a result, it has been shown that JLRs can achieve higher ozone gas transfer with lower energy consumption and perform more effective phenol and COD removal than BC reactors, especially at low pH and high ozone dosages.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/bayburt/12087Resmi atıflarda kullanılan kalıcı adres
DOI
https://doi.org/10.1016/j.jece.2020.104402Yayıncı resmi DOI adresi
İndeks kayıtları
Kaydın indeks veri tabanlarındaki sayfası (aktarımda alınan kayıt numarasıyla). Erişim, indeksin kendi koşullarına bağlıdır.
Atıflar
Scopus
40
WoS
36
OpenAlex
39
Her kaynağın kendi saydığı toplam atıf; aktarım ve zenginleştirme sırasında alındı.
Tam Kayıt
AlanDeğerDil
dc.contributor.authorBarlak, Melahat Semin
dc.contributor.authorDegermenci, Nejdet
dc.contributor.authorCengiz, Ibrahim
dc.contributor.authorUcun Özel, Handan
dc.contributor.authorYildiz, Ergun
dc.date.accessioned2026-10-29T19:09:10.429869666Z
dc.date.available2026-10-29T19:09:10.429869666Z
dc.date.issued2020
dc.description.abstractThis study aimed to remove phenol with ozonation in a jet loop reactor (JLR) and a bubble column (BC). In the first stage of the study, the mass transfer properties of JLR were determined and superiority over BC reactors were shown, and in the second stage, these reactors were used in phenol removal studies. At the same conditions, the volumetric mass transfer coefficient of JLR was 0.540 min-1, while this value was determined as 0.246 min-1 in the BC reactor. In phenol removal, the effects of initial phenol concentration, ozone dosage and pH on phenol and chemical oxygen demand (COD) removal were determined for both JLR and BC. While the pseudo-first rate constant for phenol removal in JLR at 221 mg/min ozone dosage was 0.1756 min-1, this value was only calculated as 0.1157 min-1 in the BC reactor. As a result, it has been shown that JLRs can achieve higher ozone gas transfer with lower energy consumption and perform more effective phenol and COD removal than BC reactors, especially at low pH and high ozone dosages.
dc.description.sponsorshipTÜBİTAK, (107Y298)
dc.description.sponsorshipTürkiye Bilimsel ve Teknolojik Araştirma Kurumu, TÜBITAK
dc.identifier.articlenumber104402
dc.identifier.doi10.1016/j.jece.2020.104402
dc.identifier.eissn2213-3437
dc.identifier.issn2213-3437
dc.identifier.issue5
dc.identifier.scopus2-s2.0-85092698443
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/bayburt/12087
dc.identifier.volume8
dc.identifier.wosWOS:000575524900009
dc.language.isoen
dc.publisherElsevier Ltd
dc.relation.ispartofJournal of Environmental Chemical Engineering
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.subjectbubble column
dc.subjectchemical oxygen demand
dc.subjectjet loop reactor
dc.subjectozonation
dc.subjectphenol
dc.subject.classificationEngineering, Environmental
dc.subject.classificationEngineering, Chemical
dc.subject.classificationEngineering
dc.subject.otherBubble columns
dc.subject.otherChemical oxygen demand
dc.subject.otherEnergy utilization
dc.subject.otherMass transfer
dc.subject.otherOzone
dc.subject.otherOzonization
dc.subject.otherRate constants
dc.subject.otherReactor operation
dc.subject.otherVolumetric analysis
dc.subject.otherChemical oxygen demand removals
dc.subject.otherCOD removal
dc.subject.otherJet loop reactors
dc.subject.otherLower energies
dc.subject.otherPhenol concentration
dc.subject.otherPhenol removal
dc.subject.otherTransfer properties
dc.subject.otherVolumetric mass transfer coefficient
dc.subject.otherPhenols
dc.titleComparison of phenol removal with ozonation in jet loop reactor and bubble column
dc.typeArticle
rdl.citation.openalex39
rdl.citation.scopus40
rdl.citation.wos36
rdl.oa.statusclosed
rdl.scopus.quartileQ1
rdl.sdgSDG06
rdl.sdgSDG12
rdl.source.indexSCOPUS
rdl.source.indexWOS
rdl.wos.indexScience Citation Index Expanded (SCI-EXPANDED)