Investigation of the effect of current density and PH on oil and grease removal from leather industry wastewaters by electrocoagulation method

MakaleAçık Erişim
  • SDG 6 · Temiz Su ve Sanitasyon
  • SDG 12 · Sorumlu Üretim ve Tüketim

Özet

In this study, the effects of pH and current density on the removal of high concentrations of oil and grease in leather industry wastewater by the electrocoagulation method were investigated. Two different types of electrodes were used in the study. Studies with aluminum electrodes have shown that these electrodes are more effective than iron electrodes in removing oil and grease. In addition, aluminum electrodes are affected more by the system pH than iron electrodes. Studies have shown that higher oil and grease removal efficiencies are obtained below pH 4 for both electrodes. While the oil and grease removal efficiency with Al electrodes is 95% at pH 2, this value decreases to 83% at pH 6. In Fe electrodes, while the removal efficiency is 87.83% at pH 2, it decreases to 83% at pH 6. The effect of current density on oil and grease removal was examined and it was observed that the removal efficiency remained constant above a certain current density in aluminum electrodes. While the efficiency of Al electrodes is 83.31% at 0.6 mA cm-2 current density, this value has increased to about 98% at 1.2, 1.8, and 2.4 mA cm-2 current densities. In Fe electrodes, the oil and grease removal efficiency is 82.66% at 0.6 mA cm-2 current density, while it is 90% at 1.2 and 1.8 mA cm-2 current densities and 98% at 2.4 mA cm-2. These results show that the electrocoagulation process removes the oil and grease in wastewater at a high rate. This shows that this process can also be used as pre-treatment before the biological treatment of industrial wastewater with high oil and grease content. Copyright 2021, Yıldız Technical University.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/bayburt/11588Resmi atıflarda kullanılan kalıcı adres
DOI
https://doi.org/10.14744/sigma.2022.00086Yayıncı resmi DOI adresi
İndeks kayıtları
Kaydın indeks veri tabanlarındaki sayfası (aktarımda alınan kayıt numarasıyla). Erişim, indeksin kendi koşullarına bağlıdır.
Atıflar
Scopus
2
WoS
2
OpenAlex
1
Her kaynağın kendi saydığı toplam atıf; aktarım ve zenginleştirme sırasında alındı.
Tam Kayıt
AlanDeğerDil
dc.contributor.authorBi̇Ngül Reçber, Züleyha
dc.contributor.authorEkmekyapar Torun, Fatma
dc.contributor.authorKul, Sinan
dc.contributor.authorİRdemez, Şahset
dc.date.accessioned2026-10-29T19:08:34.258926167Z
dc.date.available2026-10-29T19:08:34.258926167Z
dc.date.issued2022
dc.description.abstractIn this study, the effects of pH and current density on the removal of high concentrations of oil and grease in leather industry wastewater by the electrocoagulation method were investigated. Two different types of electrodes were used in the study. Studies with aluminum electrodes have shown that these electrodes are more effective than iron electrodes in removing oil and grease. In addition, aluminum electrodes are affected more by the system pH than iron electrodes. Studies have shown that higher oil and grease removal efficiencies are obtained below pH 4 for both electrodes. While the oil and grease removal efficiency with Al electrodes is 95% at pH 2, this value decreases to 83% at pH 6. In Fe electrodes, while the removal efficiency is 87.83% at pH 2, it decreases to 83% at pH 6. The effect of current density on oil and grease removal was examined and it was observed that the removal efficiency remained constant above a certain current density in aluminum electrodes. While the efficiency of Al electrodes is 83.31% at 0.6 mA cm-2 current density, this value has increased to about 98% at 1.2, 1.8, and 2.4 mA cm-2 current densities. In Fe electrodes, the oil and grease removal efficiency is 82.66% at 0.6 mA cm-2 current density, while it is 90% at 1.2 and 1.8 mA cm-2 current densities and 98% at 2.4 mA cm-2. These results show that the electrocoagulation process removes the oil and grease in wastewater at a high rate. This shows that this process can also be used as pre-treatment before the biological treatment of industrial wastewater with high oil and grease content. Copyright 2021, Yıldız Technical University.
dc.identifier.doi10.14744/sigma.2022.00086
dc.identifier.eissn1304-7191
dc.identifier.endpage714
dc.identifier.issn1304-7191
dc.identifier.issue4
dc.identifier.scopus2-s2.0-85160233249
dc.identifier.startpage705
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/bayburt/11588
dc.identifier.volume40
dc.identifier.wosWOS:001090928400003
dc.language.isoen
dc.publisherYildiz Technical University
dc.relation.ispartofSigma Journal of Engineering and Natural Sciences
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectAluminum Electrode
dc.subjectElectrocoagulation
dc.subjectGrease
dc.subjectIron Electrode
dc.subjectLeather Industry Wastewater
dc.subjectOil
dc.subject.classificationEngineering, Multidisciplinary
dc.subject.classificationEngineering
dc.subject.otherTANNERY WASTE-WATER
dc.subject.otherPHOSPHATE REMOVAL
dc.subject.otherPOLLUTANTS
dc.subject.otherEFFLUENT
dc.subject.otherALUMINUM
dc.titleInvestigation of the effect of current density and PH on oil and grease removal from leather industry wastewaters by electrocoagulation method
dc.typeArticle
rdl.citation.openalex1
rdl.citation.scopus2
rdl.citation.wos2
rdl.oa.statusgold
rdl.oa.urlhttps://sigma.yildiz.edu.tr/storage/upload/pdfs/1669194728-en.pdf
rdl.sdgSDG12
rdl.sdgSDG06
rdl.source.indexSCOPUS
rdl.source.indexWOS
rdl.wos.indexEmerging Sources Citation Index (ESCI)