Determination of radioprotective and genotoxic properties of sulfamide derivatives

MakaleAçık ErişimScopus SJRQ3
  • SDG 3 · Sağlık ve Kaliteli Yaşam

Özet

Some potential drug active substances with the ability to reduce the effects of radiation on human tissues and cells were investigated. For this purpose, eight different types of sulfamide derivatives were synthesized and nuclear radiation protection parameters were determined. Neutron radiation reduction parameters such as the half-value layer effective removal cross-sections, mean free path, and the number of particles passing through the sample were determined with GEANT4 code. Additionally, the gamma radiation attenuation parameters of the materials examined were determined using Phy-X/PSD software in the energy area of 0.015-15 MeV. These parameters are the half-value layer, mass attenuation coefficient, mean free path, exposure buildup factor and effective atomic number. Neutron radiation absorption experiments were applied using an 241Am-Be fast neutron source. All results obtained for neutron radiation were compared with paraffin and water. It has been found that the ability of sulfamide derivatives to absorb these radiations is superior to reference materials. To determine whether these derivatives could have adverse effects on human health, their genotoxic potential was determined using the Ames/Salmonella bacterial reversion test. The results showed that these derivatives can be considered genotoxically safe in tests at concentrations up to 5 mM. Thus, it is suggested that the derivative materials examined in this study can be used as active substances for a drug to be made for protection against both neutron and gamma radiation.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/bayburt/13472Resmi atıflarda kullanılan kalıcı adres
DOI
https://doi.org/10.1515/ract-2021-1088Yayıncı resmi DOI adresi
İndeks kayıtları
Kaydın indeks veri tabanlarındaki sayfası (aktarımda alınan kayıt numarasıyla). Erişim, indeksin kendi koşullarına bağlıdır.
Atıflar
Scopus
10
WoS
9
OpenAlex
11
Her kaynağın kendi saydığı toplam atıf; aktarım ve zenginleştirme sırasında alındı.
Tam Kayıt
AlanDeğerDil
dc.contributor.authorAygün, Bünyamin
dc.contributor.authorAlaylar, Burak
dc.contributor.authorAklncloǧlu, Akln
dc.contributor.authorAllm, Bünyamin
dc.contributor.authorKocaman, Ebu Talip
dc.contributor.authorKaradayl, Mehmet
dc.contributor.authorAbu Al-Sayyed, Mohammed Ibrahim
dc.contributor.authorAksu, Seyma
dc.contributor.authorSakar, Erdem
dc.contributor.authorÖzpolat, Özgür Flrat
dc.contributor.authorGöksu, Süleyman
dc.contributor.authorGüllüce, Medine
dc.contributor.authorKarabulut, Abdulhalik
dc.date.accessioned2026-10-29T19:11:00.995167656Z
dc.date.available2026-10-29T19:11:00.995167656Z
dc.date.issued2021
dc.description.abstractSome potential drug active substances with the ability to reduce the effects of radiation on human tissues and cells were investigated. For this purpose, eight different types of sulfamide derivatives were synthesized and nuclear radiation protection parameters were determined. Neutron radiation reduction parameters such as the half-value layer effective removal cross-sections, mean free path, and the number of particles passing through the sample were determined with GEANT4 code. Additionally, the gamma radiation attenuation parameters of the materials examined were determined using Phy-X/PSD software in the energy area of 0.015-15 MeV. These parameters are the half-value layer, mass attenuation coefficient, mean free path, exposure buildup factor and effective atomic number. Neutron radiation absorption experiments were applied using an 241Am-Be fast neutron source. All results obtained for neutron radiation were compared with paraffin and water. It has been found that the ability of sulfamide derivatives to absorb these radiations is superior to reference materials. To determine whether these derivatives could have adverse effects on human health, their genotoxic potential was determined using the Ames/Salmonella bacterial reversion test. The results showed that these derivatives can be considered genotoxically safe in tests at concentrations up to 5 mM. Thus, it is suggested that the derivative materials examined in this study can be used as active substances for a drug to be made for protection against both neutron and gamma radiation.
dc.description.sponsorshipAtaturk University
dc.description.sponsorshipTürkiye Bilimsel ve Teknolojik Araştirma Kurumu, TÜBITAK, (112T881)
dc.description.sponsorshipTürkiye Bilimsel ve Teknolojik Araştirma Kurumu, TÜBITAK
dc.identifier.doi10.1515/ract-2021-1088
dc.identifier.eissn2193-3405
dc.identifier.endpage904
dc.identifier.issn0033-8230
dc.identifier.issue12
dc.identifier.scopus2-s2.0-85118487859
dc.identifier.startpage891
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/bayburt/13472
dc.identifier.volume109
dc.identifier.wosWOS:000744642300003
dc.language.isoen
dc.publisherDe Gruyter Open Ltd
dc.relation.ispartofRadiochimica Acta
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectAmes test
dc.subjectgamma
dc.subjectneutron
dc.subjectsulfamide
dc.subjectsulfamoyl carbamate
dc.subject.classificationChemistry, Inorganic & Nuclear
dc.subject.classificationNuclear Science & Technology
dc.subject.classificationChemistry
dc.subject.otherCARBONIC-ANHYDRASE
dc.subject.otherATTENUATION PROPERTIES
dc.subject.otherSHIELDING PROPERTIES
dc.subject.otherINHIBITORS
dc.subject.otherRADIATION
dc.subject.otherALLOYS
dc.subject.otherACETYLCHOLINESTERASE
dc.subject.otherDISCOVERY
dc.subject.otherEXTRACT
dc.subject.otherDESIGN
dc.titleDetermination of radioprotective and genotoxic properties of sulfamide derivatives
dc.typeArticle
rdl.citation.openalex11
rdl.citation.scopus10
rdl.citation.wos9
rdl.oa.statusclosed
rdl.oa.statusgreen
rdl.oa.urlhttp://hdl.handle.net/20.500.12403/3159
rdl.scopus.quartileQ3
rdl.sdgSDG03
rdl.source.indexSCOPUS
rdl.source.indexWOS
rdl.wos.indexScience Citation Index Expanded (SCI-EXPANDED)