Sürdürülebilir Kalkınma Amaçları
Bu dergideki yayınlar
9 →- MakaleYalnız künye2026Scopus SJRQ1Experimental 4E analysis (energy-exergy-economic-environmental) of hybrid parabolic trough collector-thermoelectric generator-phase change material cogeneration system
Guclu, Tamer; Cuce, Pinar Mert; Cuce, Erdem
Hybrid solar cogeneration systems are critical for enhancing energy utilisation and mitigating the intermittency of solar resources. This study presents a comprehensive 4E (Energy-Exergy-Economic-Environmental) experimental analysis of a novel hybrid system that uniquely integrates a Parabolic Trough Collector (PTC), a small-scale steam turbine, a Thermoelectric Generator (TEG) assembly, and a Phase Change Material (PCM) thermal storage unit. The system's performance was investigated under 15 distinct operating conditions, varying initial water masses (0.1, 0.15, 0.2 kg) and operating pressures (6, 8, 10, 12, and 14 bar). Experimental results demonstrated the system's adaptive cogeneration capabilities. At 14 bar and 0.2 kg, the system achieved its maximum Solar-to-Electricity efficiency of 0.42%. At this operating condition, the highest collector thermal efficiency was 25.25% (at 6 bar), and the maximum overall energy and exergy efficiencies were 8.43% and 1.45%, respectively. A key finding was the system's adaptive electrical output: at low pressures (6 bar), the TEG acted as a crucial co-generator, supplying up to 55% of the electricity, whereas at high pressures (14 bar), the turbine dominated, accounting for 88-90% of the output. Furthermore, the study experimentally confirmed that latent heat transfer was the dominant heat transfer mechanism for the PCM, with latent heat contributing ∼445 kJ (55%) of the 805 kJ total energy stored. The thermo-economic analysis confirmed the system's viability, yielding a Simple Payback Period (Spp) of 6.9 years and a competitive Levelised Cost of Energy (LCOE) of $0.101/kWh. The system is projected to save 118.8 kg of CO2 and 660 L of water annually. The results validate the thermodynamic and economic feasibility of the integrated PTC-Turbine-TEG-PCM concept as a flexible solution for small-scale solar cogeneration.
AtıfScopus3WoS2OpenAlex6İncele
- MakaleAçık Erişim2024Scopus SJRQ1District heating based on exhaust gas produced from end-of-life tires in Erzincan: Thermoeconomic analysis and optimization
Güngör, Osman; Tozlu, Alperen; Arslantürk, Cihat; Özahi, Emrah
This paper presents the thermoeconomic analysis and optimization of the Erzincan Waste Tire Recycling and Power Plant (EWTRPP) in Turkey and its waste heat-based district heating (DH) system. A thermoeconomical method, namely the specific exergy costing (SPECO), is applied to allocate cost flows through subcomponents of an actual existing plant. Besides, the obtained thermoeconomic results are improved by using an optimization method, namely non-dominant sorting genetic algorithm (NSGA-II), considering the temperature of the exhaust gas discharged to the atmosphere (T25), the thermal conductivity value of the insulation material (ki) and pipe roughness value (s). The energy and exergy efficiencies of the existing plant are found to be 27.37% and 35.57%, respectively, considering the data of the actual plant. Moreover, the energy and exergy efficiencies of the waste heat-based DH system are found to be 43.08% and 55.99%, respectively. The total cost rate of the overall system is deduced 13.98 $/hby means of SPECO method. According to the results of the NSGA-II optimization method, the exergy efficiency and total cost rate of the overall system are evaluated as 6.93% and −2.51 $/h, respectively. Furthermore, it is also proposed that 1304 dwellings can be heated owing to the DH system utilizing the existing exhaust gas.
AtıfScopus9WoS8OpenAlex7İncele
- MakaleAçık Erişim2021Scopus SJRQ1District heating and electricity production based on biogas produced from municipal WWTPs in Turkey: A comprehensive case study
Abusoglu, Aysegul; Tozlu, Alperen; Anvari-Moghaddam, Amjad
In this paper, district heating (DH) potentials of the wastewater treatment plants (WWTPs) based on their biogas, electricity, and heat productions are considered. Two district heating scenarios are developed: (i) DH Scenario I which is based on both excess biogas storage of the WWTP and exhaust gas of the cogeneration with the actual power output, (ii) DH Scenario II which is based on the exhaust gas of the cogeneration with the increased power output using all the biogas produced. In DH Scenario I, it is found that 458 dwellings can be heated via the DH system proposed considering only the waste heat of the cogeneration. In addition, the natural gas consumption of 1112 dwellings with the same annual heating load can also be met using the purified biogas. In DH Scenario II, the electricity production could be increased to 1643 kWh by burning all the biogas produced in the cogeneration plant. In this scenario, the annual heating load of 755 dwellings in Gaziantep province can be covered using the waste heat in the DH system. The payback period for the DH Scenario I is calculated as 2.5 years, while for the DH Scenario II, it is obtained as 2 years.
AtıfScopus27WoS28İncele
- MakaleYalnız künye2018Scopus SJRQ1Thermoeconomic analysis and optimization of a Re-compression supercritical CO2 cycle using waste heat of Gaziantep Municipal Solid Waste Power Plant
Tozlu, Alperen; Abuşoğlu, Ayşegül; Özahi, Emrah
This paper presents thermodynamic and thermoeconomic analyses as well as optimization of a re-compression supercritical CO2 cycle. A gas turbine cycle (GT) is adapted as a model to an existing plant to generate additional power in Gaziantep Municipal Solid Waste Power Plant (GMSWPP). The total capital cost rate and total cost rate of the GT cycle are found to be 20.47 $/h and 77.14 $/h, respectively utilizing SPECO by using the exhaust gas of 16 kg/s with 1.9 bar and 566.7 °c. The net power, the energy and exergy efficiencies, the total cost and the total capital cost rates of the GT cycle are optimized by +1.73%, +3.21%, +2.45%, −1.11% and −1.64%, respectively using NSGA-II in MATLAB in the range of 2.5≤PR≤4, 200≤P6≤216, 16≤T0≤23 and 9.1≤LMTD≤12.9. This paper provides an originality such that optimization as well as thermodynamic and thermoeconomic analyses is performed simultaneously for an existing MSW power plant, which can be stressed that there are scarce amounts of studies related on this field. Moreover, as another novelty, it can be emphasized that net power output of such like plants which have similar capacity can be improved using the developed model and NSGA-II optimization method.
AtıfScopus47WoS43OpenAlex48İncele
- MakaleYalnız künye2017Scopus SJRQ1Toward cost-effective and energy-efficient heat recovery systems in buildings: Thermal performance monitoring
Cuce, Pinar Mert; Cuce, Erdem
Recent studies show that it is possible to reduce heating or cooling demand of a building as using heat recovery systems. Heat recovery technology is basically utilised to mitigate the heat loss, and hence energy consumption due to HVAC. Within the scope of this study, thermal comfort analyses of a test house integrated with a novel polycarbonate heat exchanger are conducted. At pre and post-retrofit case, temperature, relative humidity and CO2 measurements are carried out for a test period of one week. The results indicate that the internal CO2 concentration is not at desirable range due to lack of ventilation in the test house at the pre-retrofit case. However, following the integration of the novel ventilation system into the test house, CO2 concentration is found to be varying notably from 350 to 400 ppm which corresponds to the actual comfort conditions for indoor environments. It is also concluded from the results that the average relative humidity inside the test house at the post-retrofit case is found to be 57%, which is in the desired range whereas it is considerably high before retrofitting.
AtıfScopus26WoS25OpenAlex33İncele
- MakaleAçık Erişim2017Scopus SJRQ1An energy prediction algorithm for wind-powered wireless sensor networks with energy harvesting
Kosunalp, Selahattin
Energy harvesting (EH) from environmental energy sources has the potential to ensure unlimited, uncontrollable and unreliable energy for wireless sensor networks (WSNs), bringing a need to predict future energy availability for the effective utilization of the harvested energy. The majority of previous prediction approaches have exploited the diurnal cycle dividing the whole day into equal-length time slots in which predictions were carried out in each slot independently. This is not, however, efficient for wind energy as it exhibits non-controllable behaviour in that the amount of energy to be harvested varies over time. This paper proposes a novel approach to predict the wind energy for EH-WSNs depending on the energy generation profile of latest condition. The distinctive feature of the proposed approach is to consider the recent conditions in current-day, instead of past-day's energy generation profiles. The performance of the proposed algorithm is evaluated using real measurements in comparison with state-of-art approaches. Results show that the proposed strategy significantly outperforms the two popular energy predictors, EWMA and Pro-Energy.
AtıfScopus48WoS36OpenAlex51İncele
- MakaleYalnız künye2016Scopus SJRQ1Energy saving potential of heat insulation solar glass: Key results from laboratory and in-situ testing
Cuce, Erdem; Cuce, Pinar Mert; Young, Chin-Huai
HISG (heat insulation solar glass) is a recently developed multi-functional glazing technology to mitigate energy consumption of buildings. HISG can generate electricity similar to conventional PV (photovoltaic) glazing products when exposed to sunlight, however it differs from them by having some extraordinary characteristic features such as thermal insulation, which is competitive with Argon filled triple glazed windows, acoustic comfort, remarkable energy saving potential and self-cleaning ability owing to TiO2 nano coating. Within the scope of this research, latest results from laboratory and in-situ testing of HISG are presented in terms of its key role in mitigating heating and cooling demand of buildings as well as clean energy generation. Lighting and thermal comfort related parameters such as shading coefficient, UV, IR and visible light intensity are also investigated through the tests conducted in real operating conditions. It is achieved from the results that instant electricity generation of HISG is 16% higher than that of standard PV glazing owing to its nano layer reflective film. Shading coefficient of HISG is only 0.136, which provides almost 80% reduction in solar heat gain compared to ordinary glazing. Indoor air temperature measured from HISG test house in summer time is very close to the ambient temperature, whereas it is found to be 14.7 °C higher in ordinary glass test house due to greenhouse effect. Annual heating and cooling demand tests indicate that HISG provides 38 and 48% energy saving in heating and cooling season, respectively.
AtıfScopus52WoS46OpenAlex56İncele
- MakaleYalnız künye2015Scopus SJRQ1Thermoeconomic optimization of gas turbine cogeneration plants
Karaali, Rabi; Öztürk, Ilhan Tekin
In this study, a novel thermoeconomic optimization method that is simple and efficient, for real complex cycles is introduced. First, a thermoeconomic analysis method that is called non-linear simplex direct search method is improved for the purposes of this study. The objective of this paper is to apply this method to four cogeneration cycles that are simple cycle, inlet air cooling cycle, air preheated and air-fuel preheated cycles for analyzing and optimizing. The four cycles are thermoeconomically optimized for constant power and steam mass (30 MW and 14 kg/s saturated steam flow rate at 2000 kPa), for constant power (30 MW) and for variable steam mass, and for variable power and steam mass by using the cost equation method and the effect of size on equipment method. The results obtained by the effect of size on equipment and by the cost equations methods are very different from each other. For the case of global optimization, the optimum electricity costs which also correspond to minimum are obtained as 0,0432 $/kWh for simple cycle, 0,0514 $/kWh for inlet air cooling cycle 0,0577 $/kWh for air preheated cycle and 0,058 $/kWh for air-fuel preheated cycle by using cost equations method. (C) 2014 Elsevier Ltd. All rights reserved.
AtıfWoS32OpenAlex39İncele
- MakaleYalnız künye2013Scopus SJRQ1An experimental exergetic comparison of four different heat pump systems working at same conditions: As air to air, air to water, water to water and water to air
Çakir, Uǧur; Çomakli, Kemal; Çomakli, Ömer; Karsli, Süleyman
In this study, we designed a multifunctional heat pump system using just one scroll compressor and which can be run in four different modes, namely air to air, air to water, water to water and water to air, in order to make an experimental energetic and exergetic performance comparison. Experimental system consists of two condensers and two evaporators and uses R22 as working fluid. One of the evaporators and condensers uses water and the others use air as heat source/sink. Heating capacities of four heat pump types are equal to each other. It is realized by adjusting the mass flow rate and temperature level of external fluid of condenser. Results show that the heat pump unit which has the maximum COP (coefficient of performance) value is water to air type with 3.94 and followed by water to water type with 3.73, air to air type with 3.54 and air to water type with 3.40. Ranking of four heat pump types with respect to their mean exergy efficiency is as follows; water to air type with 30.23%, air to air type with 30.22%, air to water type with 24.77% and water to water type with 24.01%. Exergy destruction rates of the systems were investigated in this study and the results revealed that the heat pump type which has the maximum exergy destruction is air to air type with 2.93kW. The second highest one is air to water type with 2.84kW. The third highest one is water to air type with 2.64kW and last one is water to water type with 2.55kW. It is understood that the temperature of the evaporator external fluid affects the exergetic efficiency of the system more than the mass flow rate. In contrast to the previous, the dominant parameter which has more important effect on the exergy destruction of the heat pump unit is the mass flow rate of evaporator external fluid.
AtıfScopus55WoS46İncele
Tam Kayıt
| Alan | Değer | Dil |
|---|---|---|
| creativeworkseries.issn | 0360-5442 | |
| dc.date.accessioned | 2026-10-29T19:07:55.132694381Z | |
| dc.date.available | 2026-10-29T19:07:55.132694381Z | |
| dc.identifier.uri | https://rdlopen.rawdatalibrary.net/r/bayburt/10962 | |
| dc.publisher | Elsevier Ltd | |
| dc.rights | info:eu-repo/semantics/openAccess | |
| dc.title | Energy |





