  • MakaleAçık Erişim2020
    Optimising High Lime Fly Ash Content By Means of Silica Fume Incorporation to Control Alkali-Silica Reaction And Drying Shrinkage of Mortars

    Gökçe, H. Suleyman; Hosseinnezhad, Hojjat; Üzüm, Onur; Hatungimana, Daniel; Ramyar, Kambiz

    In this study, the effect of binary and ternary cementitious systems composed of portland cement, high-lime fly ash and silica fume on the compressive strength, alkali-silica reaction (ASTM C 1567) and drying shrinkage of mortar mixtures was researched. For this purpose, binary and ternary binders were prepared with partial replacement of cement with either fly ash (15wt% and 30wt%) or silica fume (5wt%) or both mineral admixtures (15wt+%5wt% and 30wt%+5wt%). An alkali reactive basalt aggregate was used in this study. It was found that partial replacement of cement with high-lime fly ash reduced the strength of mortar mixtures even up to 28-days. Besides, addition of 5% silica fume had not a significant effect on the early strength of fly ash-bearing mixtures. However, silica fume inclusion improved the 28-day strength of mixtures. In terms of alkali-silica reaction (ASR), the fly ash with lower lime content reduced the 14-day expansion more than that of fly ash with higher lime content. The opposite results were the case in 28-day ASR expansions. The ASR expansions of the fly ash-bearing mixtures were significantly reduced by the introduction of the additional 5% silica fume to these mixtures. However, silica fume incorporation remarkably increased the drying shrinkage values of the mixtures. Finally, fly ash with higher lime content was found to be more satisfactory in terms of compressive strength, alkali-silica reaction and drying shrinkage in the ternary binder system.

    • SDG 12 · Sorumlu Üretim ve Tüketim
    AtıfOpenAlex1
    Web of ScienceTR Dizinİncele
  • MakaleYalnız künye2020Scopus SJRQ1
    Natural radioactivity of barite concrete shields containing commonly used supplementary materials

    Gökçe, H.S.; Canbaz Öztürk, B.; Çam, N.F.; Andiç-Çakır, Ö.

    The recycling of hazardous materials within new composites has a sustainable importance as it contributes on the reduction of high radionuclide concentrations. In this study, the effect of cementitious materials i.e. viscosity modifier, silica fume and fly ash on the 226Ra, 232Th and 40K activity levels of barite concrete shields was researched by using different mixing compositions in terms of binder content, w/b ratio and the amount of supplementary cementitious materials. In comparison to cement, silica fume and fly ash used in the production of concrete shields were found to have significantly higher activity levels of 40K, as well as 226Ra, 232Th and 40K, respectively. The 226Ra, 232Th and 40K activity levels of concrete shields range between 2.2 and 20.7 Bq kg−1; 2.6 and 7.0 Bq kg−1; 51.5 and 89.3 Bq kg−1, respectively. These activity values were found similar or less than those of building materials in the world. These satisfactory results are mostly caused by the barite source which has lower radioactivity levels. The concrete mixture details used in the study caused significant variation in the natural radioactivity of barite concrete shields. The introduction of silica fume which has high 40K activity levels and fly ash with high 226Ra, 232Th and 40K activity levels compared to cement and barite aggregate, significantly increased the radiological hazard parameters, although all results were found to be below the limits recommended by international reports. In conclusion, 226Ra activity levels of the concrete shields were significantly increased (up to 8.4 times) by the variation of mix design parameters used in comparison with concrete mixtures that have the least 226Ra activity level. The 232Th and 40K activity levels were as well increased in relatively less amounts (1.7 and 0.73 times higher, respectively).

    • SDG 12 · Sorumlu Üretim ve Tüketim
    AtıfScopus22WoS20OpenAlex23
    ScopusWeb of Scienceİncele
  • MakaleAçık Erişim2011Scopus SJRQ3
    The effects of silica fume and fly ash on the scaling resistance and flexural strength of pavement concretes

    Yener, Engin; Hinislioğlu, Sinan

    The purpose of this study is to investigate the effects of Silica Fume (SF) and Fly Ash (FA) additives on the frost salt scaling resistance and flexural strength properties of pavement concrete. An attempt is also made to attain a more durable and higher strength concrete by a suitable combination of Ordinary Portland Cement (OPC), SF and FA. SF and FA are used as cement replacement in proportions of 0, 5, 10% and 0, 5, 10, 15% by weight respectively. Flexural strength is tested after 7, 28 and 91 days of the lime saturated water curing period. The experimental results indicate that using FA only decreases while SF only slightly increases 28-days flexural strength. On the other hand, using SF and FA together shows relatively more strength gain. Among all those tested, maximum 28 days flexural strength of 4.53 MPa is obtained for the mix proportions of 85% OPC + 10% FA and 5% SF. SF significantly decreases the amount of liquid absorption by capillary suction and has a significant effect on the scaling resistance. In addition, all the ternary mixtures showes better scaling resistance than the control mixture with 100% OPC.

    • SDG 9 · Sanayi, Yenilikçilik ve Altyapı
    AtıfScopus9OpenAlex25
    Scopusİncele
  • MakaleAçık Erişim2011Scopus SJRQ3
    The effects of silica fume and fly ash on the scaling resistance and flexural strength of pavement concretes

    Yener, Engin; Hinislioǧlu, Sinan

    The purpose of this study is to investigate the effects of Silica Fume (SF) and Fly Ash (FA) additives on the frost salt scaling resistance and flexural strength properties of pavement concrete. An attempt is also made to attain a more durable and higher strength concrete by a suitable combination of Ordinary Portland Cement (OPC), SF and FA. SF and FA are used as cement replacement in proportions of 0, 5, 10% and 0, 5, 10, 15% by weight respectively. Flexural strength is tested after 7, 28 and 91 days of the lime saturated water curing period. The experimental results indicate that using FA only decreases while SF only slightly increases 28-days flexural strength. On the other hand, using SF and FA together shows relatively more strength gain. Among all those tested, maximum 28 days flexural strength of 4.53 MPa is obtained for the mix proportions of 85% OPC + 10% FA and 5% SF. SF significantly decreases the amount of liquid absorption by capillary suction and has a significant effect on the scaling resistance. In addition, all the ternary mixtures showes better scaling resistance than the control mixture with 100% OPC.

    AtıfScopus13WoS23
    ScopusWeb of Scienceİncele