- MakaleYalnız künye2017Scopus SJRQ1Toward cost-effective and energy-efficient heat recovery systems in buildings: Thermal performance monitoring
Cuce, Pinar Mert; Cuce, Erdem
Recent studies show that it is possible to reduce heating or cooling demand of a building as using heat recovery systems. Heat recovery technology is basically utilised to mitigate the heat loss, and hence energy consumption due to HVAC. Within the scope of this study, thermal comfort analyses of a test house integrated with a novel polycarbonate heat exchanger are conducted. At pre and post-retrofit case, temperature, relative humidity and CO2 measurements are carried out for a test period of one week. The results indicate that the internal CO2 concentration is not at desirable range due to lack of ventilation in the test house at the pre-retrofit case. However, following the integration of the novel ventilation system into the test house, CO2 concentration is found to be varying notably from 350 to 400 ppm which corresponds to the actual comfort conditions for indoor environments. It is also concluded from the results that the average relative humidity inside the test house at the post-retrofit case is found to be 57%, which is in the desired range whereas it is considerably high before retrofitting.
AtıfScopus26WoS25OpenAlex33İncele
- MakaleAçık Erişim2016Scopus SJRQ1The impact of internal aerogel retrofitting on the thermal bridges of residential buildings: An experimental and statistical research
Cuce, Erdem; Cuce, Pinar Mert
In this research, internal thermal superinsulation in residential buildings is experimentally and statistically evaluated in terms of potential thermal bridging effects. As a consequence of significant deviations in thermal resistance values in buildings at post-retrofit, large amounts of heat losses occur through non-insulated building elements such as separating walls. Therefore, it is of vital importance to determine the level of energy loss due to such thermal bridges through an internal thermal superinsulation retrofit conducted in a typical UK building. 20 mm thick fibre-silica opaque aerogel blanket is implemented internally on the walls of a test bedroom, and the heat flux from the separating wall is measured and compared for the cases of pre and post-retrofit. The results reveal that the average amount of heat loss through the non-insulated separating wall at the post-retrofit is 5.86 W/m2, whereas it is only 0.66 W/m2 at the pre-retrofit. The results are also verified through a statistical model, which is presented for the first time in literature. The novel model is capable of providing information about potential energy loss from non-insulated walls as a function of location.
AtıfScopus60WoS54OpenAlex69İncele