The Investigation of COD Treatment and Energy Consumption of Urban Wastewater by a Continuous Electrocoagulation System

MakaleAçık ErişimScopus SJRQ2
  • SDG 6 · Temiz Su ve Sanitasyon
  • SDG 7 · Erişilebilir ve Temiz Enerji
  • SDG 12 · Sorumlu Üretim ve Tüketim

Özet

In this study, electrochemical treatment of urban wastewater with electrical conductivity of 1000 µS cm-1 and chemical oxygen demand of 250 mg L-1 was investigated using the variables of initial pH value, current density and flow rate. Electrocoagulation was used, in which aluminum and stainless steel were selected, as the electrochemical treatment process. The electrocoagulation process was operated in continuous mode. The data obtained in experimental studies show that the best COD removal efficiency occurred in experiments where the initial pH value was 6. The increase in current density from 5 A to 15 A decreased the removal efficiency from 79 to 67%. The increase in flow rate under constant current density also reduced the efficiency of removal as expected. In experiments in which current density and flow rate were examined together, the increase in flow rate allowed the application of higher current densities. This situation led to considerable reductions in energy consumption values, even if the COD removal efficiency did not significantly increase. The high COD removal obtained with the use of high flow rate and high current density indicates that the electrocoagulation process can be used for high flow rate municipal wastewater treatment.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/bayburt/13438Resmi atıflarda kullanılan kalıcı adres
DOI
https://doi.org/10.33961/jecst.2021.00647Yayıncı resmi DOI adresi
İndeks kayıtları
Kaydın indeks veri tabanlarındaki sayfası (aktarımda alınan kayıt numarasıyla). Erişim, indeksin kendi koşullarına bağlıdır.
Atıflar
Scopus
6
WoS
5
OpenAlex
5
Her kaynağın kendi saydığı toplam atıf; aktarım ve zenginleştirme sırasında alındı.
Tam Kayıt
AlanDeğerDil
dc.contributor.authorDede Sağsöz, Yeşim
dc.contributor.authorYilmaz, Alper Erdem
dc.contributor.authorEkmekyapar Torun, Fatma
dc.contributor.authorKocadağistan, Beyhan
dc.contributor.authorKul, Sinan
dc.date.accessioned2026-10-29T19:10:57.831468199Z
dc.date.available2026-10-29T19:10:57.831468199Z
dc.date.issued2022
dc.description.abstractIn this study, electrochemical treatment of urban wastewater with electrical conductivity of 1000 µS cm-1 and chemical oxygen demand of 250 mg L-1 was investigated using the variables of initial pH value, current density and flow rate. Electrocoagulation was used, in which aluminum and stainless steel were selected, as the electrochemical treatment process. The electrocoagulation process was operated in continuous mode. The data obtained in experimental studies show that the best COD removal efficiency occurred in experiments where the initial pH value was 6. The increase in current density from 5 A to 15 A decreased the removal efficiency from 79 to 67%. The increase in flow rate under constant current density also reduced the efficiency of removal as expected. In experiments in which current density and flow rate were examined together, the increase in flow rate allowed the application of higher current densities. This situation led to considerable reductions in energy consumption values, even if the COD removal efficiency did not significantly increase. The high COD removal obtained with the use of high flow rate and high current density indicates that the electrocoagulation process can be used for high flow rate municipal wastewater treatment.
dc.identifier.doi10.33961/jecst.2021.00647
dc.identifier.endpage268
dc.identifier.issn2093-8551
dc.identifier.issue2
dc.identifier.scopus2-s2.0-85131232827
dc.identifier.startpage261
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/bayburt/13438
dc.identifier.volume13
dc.identifier.wosWOS:000808459600010
dc.language.isoen
dc.publisherKorean Electrochemical Society
dc.relation.ispartofJournal of Electrochemical Science and Technology
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectContinuous electrocoagulation
dc.subjectCurrent density
dc.subjectElectrocoagulation
dc.subjectUrban wastewater
dc.subject.classificationElectrochemistry
dc.subject.otherBORON REMOVAL
dc.subject.otherOPTIMIZATION
dc.subject.otherFLUORIDE
dc.subject.otherZINC
dc.titleThe Investigation of COD Treatment and Energy Consumption of Urban Wastewater by a Continuous Electrocoagulation System
dc.typeArticle
rdl.citation.openalex5
rdl.citation.scopus6
rdl.citation.wos5
rdl.oa.statusgold
rdl.oa.urlhttps://www.jecst.org/upload/pdf/jecst-2021-00647.pdf
rdl.scopus.quartileQ2
rdl.sdgSDG06
rdl.sdgSDG12
rdl.sdgSDG07
rdl.source.indexSCOPUS
rdl.source.indexWOS
rdl.wos.indexScience Citation Index Expanded (SCI-EXPANDED)