INVESTIGATION OF THE EFFECTIVENESS OF VISCOUS DAMPERS CONNECTED TO ADJACENT BUILDINGS ON DYNAMIC BEHAVIOR UNDER SOIL-STRUCTURE INTERACTION EFFECTS

BildiriYalnız künye

Özet

In this study, the dynamic behavior of two adjacent structures with fluid viscous damper (FVD) was investigated under the influence of earthquake and considering soil-structure interaction (SSI). Adjacent structures with FVD’s were analysed for three different soil types. The modelling and analysis were made in two-dimensional (2D) space by using ANSYS package program. Viscous boundary conditions were used on the boundaries of 2D soil model. The analyses results were obtained in terms of displacement, acceleration, and shear force. The effect of FVD was investigated using different connection types. The damping coefficient of FVD’s was assumed constant in all analyses. When the results of the analysis are examined, it can be seen that FVD’s are effective for seismic response. However, it is necessary to consider the soil-structure interaction. Significant different structural results were obtained between fixed support and three different soil types. For example, in the same model, while the top floor displacement may reduce in Soil Type I, the top floor displacement may increase in Soil Type II. At the end of the study, it was seen that there was no need to connect the FVD to all floors. It was found sufficient to connect a fluid viscous damper only to the top floor (1 FVD) or to the top and middle floor (2 FVD). FVD’s have no effect on buildings with the similar dynamic character. In the analysis for seismic control of adjacent buildings, the effect of soil-structure interaction should certainly be taken into account.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/bayburt/13302Resmi atıflarda kullanılan kalıcı adres
İndeks kayıtları
Kaydın indeks veri tabanlarındaki sayfası (aktarımda alınan kayıt numarasıyla). Erişim, indeksin kendi koşullarına bağlıdır.
Atıflar
Scopus
3
Her kaynağın kendi saydığı toplam atıf; aktarım ve zenginleştirme sırasında alındı.
Tam Kayıt
AlanDeğerDil
dc.contributor.authorHatıpoğlu, Yavuz Selim
dc.contributor.authorDüzgün, Oğuz Akın
dc.date.accessioned2026-10-29T19:10:45.850383940Z
dc.date.available2026-10-29T19:10:45.850383940Z
dc.date.issued2020
dc.description.abstractIn this study, the dynamic behavior of two adjacent structures with fluid viscous damper (FVD) was investigated under the influence of earthquake and considering soil-structure interaction (SSI). Adjacent structures with FVD’s were analysed for three different soil types. The modelling and analysis were made in two-dimensional (2D) space by using ANSYS package program. Viscous boundary conditions were used on the boundaries of 2D soil model. The analyses results were obtained in terms of displacement, acceleration, and shear force. The effect of FVD was investigated using different connection types. The damping coefficient of FVD’s was assumed constant in all analyses. When the results of the analysis are examined, it can be seen that FVD’s are effective for seismic response. However, it is necessary to consider the soil-structure interaction. Significant different structural results were obtained between fixed support and three different soil types. For example, in the same model, while the top floor displacement may reduce in Soil Type I, the top floor displacement may increase in Soil Type II. At the end of the study, it was seen that there was no need to connect the FVD to all floors. It was found sufficient to connect a fluid viscous damper only to the top floor (1 FVD) or to the top and middle floor (2 FVD). FVD’s have no effect on buildings with the similar dynamic character. In the analysis for seismic control of adjacent buildings, the effect of soil-structure interaction should certainly be taken into account.
dc.description.sponsorshipBayburt Üniversitesi, BÜ
dc.identifier.endpage72
dc.identifier.issn1304-7191
dc.identifier.scopus2-s2.0-85137433314
dc.identifier.startpage51
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/bayburt/13302
dc.identifier.volume11
dc.language.isoen
dc.publisherYildiz Technical University
dc.relation.ispartofSigma Journal of Engineering and Natural Sciences
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.subjectadjacent buildings
dc.subjectFluid viscous dampers
dc.subjectseismic response
dc.subjectsoil- structure interaction
dc.subjectviscous boundary
dc.titleINVESTIGATION OF THE EFFECTIVENESS OF VISCOUS DAMPERS CONNECTED TO ADJACENT BUILDINGS ON DYNAMIC BEHAVIOR UNDER SOIL-STRUCTURE INTERACTION EFFECTS
dc.typeConference Object
rdl.citation.scopus3
rdl.oa.statusclosed
rdl.source.indexSCOPUS