Examination of absorption effects at the Compton to coherent scattering intensities X-rays using Fe-Ca and Fe-Ti binary compounds with WDXRF

BildiriYalnız künye

Özet

Matrix absorption effects have been examined with scattered X-rays by using WDXRF system for Fe-Ca and Fe-Ti binary compounds. Fe as analyte and elements which some of them the K absorption edge just below the characteristic K X-ray energies of the analyte (Fe) as matrix have been chosen. Pure and binary with Fe ratio ranging from 10% to 90% samples were prepared with these elements. These samples have been analyzed in WDXRF system. At the end of measurement, the coherent and Compton scattering X-rays data of Rh Kα X-rays from these samples have been obtained. Matrix absorption effects have been examined by calculating coherent / Compton scattered X-rays intensity ratio.

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/bayburt/12584Resmi atıflarda kullanılan kalıcı adres
DOI
https://doi.org/10.1063/1.4981736Yayıncı resmi DOI adresi
İndeks kayıtları
Kaydın indeks veri tabanlarındaki sayfası (aktarımda alınan kayıt numarasıyla). Erişim, indeksin kendi koşullarına bağlıdır.
Atıflar
Scopus
3
WoS
2
OpenAlex
2
Her kaynağın kendi saydığı toplam atıf; aktarım ve zenginleştirme sırasında alındı.
Tam Kayıt
AlanDeğerDil
dc.contributor.authorBoydaş, Elif
dc.contributor.authorBoydaş, Mustafa Gökalp
dc.contributor.authorAllm, Bünyamin
dc.contributor.editorAkdemir, A.O.
dc.contributor.editorEkinci, A.
dc.contributor.editorHan, I.
dc.contributor.editorOztekin, A.
dc.contributor.editorSet, E.
dc.contributor.editorDadasoglu, F.
dc.contributor.editorKaragoz, K.
dc.date.accessioned2026-10-29T19:09:45.829986646Z
dc.date.available2026-10-29T19:09:45.829986646Z
dc.date.issued2017
dc.description.abstractMatrix absorption effects have been examined with scattered X-rays by using WDXRF system for Fe-Ca and Fe-Ti binary compounds. Fe as analyte and elements which some of them the K absorption edge just below the characteristic K X-ray energies of the analyte (Fe) as matrix have been chosen. Pure and binary with Fe ratio ranging from 10% to 90% samples were prepared with these elements. These samples have been analyzed in WDXRF system. At the end of measurement, the coherent and Compton scattering X-rays data of Rh Kα X-rays from these samples have been obtained. Matrix absorption effects have been examined by calculating coherent / Compton scattered X-rays intensity ratio.
dc.identifier.articlenumber020088
dc.identifier.doi10.1063/1.4981736
dc.identifier.isbn978-073541503-4
dc.identifier.issn0094-243X
dc.identifier.scopus2-s2.0-85019193690
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/bayburt/12584
dc.identifier.volume1833
dc.identifier.wosWOS:000405093100088
dc.language.isoen
dc.publisherAmerican Institute of Physics Inc.
dc.relation.conference2nd International Conference on Advances in Natural and Applied Sciences, ICANAS 2017
dc.relation.ispartofAIP Conference Proceedings
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.subject.classificationPhysics, Applied
dc.subject.classificationPhysics, Multidisciplinary
dc.subject.classificationPhysics
dc.subject.otherPROFILES
dc.titleExamination of absorption effects at the Compton to coherent scattering intensities X-rays using Fe-Ca and Fe-Ti binary compounds with WDXRF
dc.typeConference Object
rdl.citation.openalex2
rdl.citation.scopus3
rdl.citation.wos2
rdl.conference.date18 April 2017 through 21 April 2017
rdl.conference.placeAntalya
rdl.oa.statusclosed
rdl.source.indexSCOPUS
rdl.source.indexWOS
rdl.wos.indexConference Proceedings Citation Index - Science (CPCI-S)