Applicability of Phenolic Profile Analysis Method Developed with RP-HPLC-PDA to some Bee Product

MakaleAçık ErişimScopus SJRQ2

Özet

In this work, a reverse phase high-performance liquid chromatographic method (RP-HPLC) with photo diode array (PDA) at 4 different wavelengths (250, 280, 320 and 360) for the determination of some polyphenols in some bee products (honey, pollen, and propolis) is developed. The analyses were carried out on C18 column (250 mm x 4.6 mm, 5 μm; GL Sciences), and the gradient program was used with a mobile phase A reservoir with 70% acetonitrile and the B reservoir with 2% acetic acid. The HPLC method was founded that limit of detection was in the range 0.022-0.0908 μg/mL; the limit of quantification was in the range 0.074-0.3027 μg/mL, all calibration curves were linear R2>0.995 within the range, the recovery range was 91.43-111.37% for 10 ppm and 98.44-101.68% for 40 ppm and relative error levels 0.0330-0.0290 respectively. The developed method was applied to some bee products available on the Turkey market. The study aimed at phenolic profiles of the bee products extracts were revealed by using 25 phenolic standards. The proposed method was optimized, quickly, and simple validated by evaluating the linear range, the limits of detection and quantification, the accuracy, the precious, the repeatability, and recoveries suitable for the phenolic analysis. It is concluded that evaluated and the quantitative determination of the bee products can be made quickly and reliably with the optimized method.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/bayburt/12144Resmi atıflarda kullanılan kalıcı adres
İndeks kayıtları
Kaydın indeks veri tabanlarındaki sayfası (aktarımda alınan kayıt numarasıyla). Erişim, indeksin kendi koşullarına bağlıdır.
Atıflar
Scopus
35
WoS
35
OpenAlex
41
Her kaynağın kendi saydığı toplam atıf; aktarım ve zenginleştirme sırasında alındı.
Tam Kayıt
AlanDeğerDil
dc.contributor.authorKara, Yakup
dc.contributor.authorCan, Zehra
dc.contributor.authorKolaylı, Sevgi
dc.date.accessioned2026-10-29T19:09:14.240152560Z
dc.date.available2026-10-29T19:09:14.240152560Z
dc.date.issued2022
dc.description.abstractIn this work, a reverse phase high-performance liquid chromatographic method (RP-HPLC) with photo diode array (PDA) at 4 different wavelengths (250, 280, 320 and 360) for the determination of some polyphenols in some bee products (honey, pollen, and propolis) is developed. The analyses were carried out on C18 column (250 mm x 4.6 mm, 5 μm; GL Sciences), and the gradient program was used with a mobile phase A reservoir with 70% acetonitrile and the B reservoir with 2% acetic acid. The HPLC method was founded that limit of detection was in the range 0.022-0.0908 μg/mL; the limit of quantification was in the range 0.074-0.3027 μg/mL, all calibration curves were linear R2>0.995 within the range, the recovery range was 91.43-111.37% for 10 ppm and 98.44-101.68% for 40 ppm and relative error levels 0.0330-0.0290 respectively. The developed method was applied to some bee products available on the Turkey market. The study aimed at phenolic profiles of the bee products extracts were revealed by using 25 phenolic standards. The proposed method was optimized, quickly, and simple validated by evaluating the linear range, the limits of detection and quantification, the accuracy, the precious, the repeatability, and recoveries suitable for the phenolic analysis. It is concluded that evaluated and the quantitative determination of the bee products can be made quickly and reliably with the optimized method.
dc.identifier.articlenumbere22210384
dc.identifier.doi10.1590/1678-4324-2022210384
dc.identifier.eissn1678-4324
dc.identifier.issn1516-8913
dc.identifier.scopus2-s2.0-85141124798
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/bayburt/12144
dc.identifier.volume65
dc.identifier.wosWOS:000855790400001
dc.language.isoen
dc.publisherInstituto de Tecnologia do Parana
dc.relation.ispartofBrazilian Archives of Biology and Technology
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectBee products
dc.subjectFlavonoids
dc.subjectHplc-pda
dc.subjectOptimization
dc.subjectPhenolic
dc.subjectValidation
dc.subject.classificationBiology
dc.subject.classificationLife Sciences & Biomedicine - Other Topics
dc.subject.otherANTIOXIDANT ACTIVITY
dc.subject.otherPROPOLIS
dc.subject.otherFLAVONOIDS
dc.subject.otherEXTRACTION
dc.subject.otherWINES
dc.titleApplicability of Phenolic Profile Analysis Method Developed with RP-HPLC-PDA to some Bee Product
dc.typeArticle
rdl.citation.openalex41
rdl.citation.scopus35
rdl.citation.wos35
rdl.oa.statusgold
rdl.oa.urlhttps://www.scielo.br/j/babt/a/RR4LtDsPGgR8QJJtJZB3mBM/?lang=en&format=pdf
rdl.scopus.quartileQ2
rdl.source.indexSCOPUS
rdl.source.indexWOS
rdl.wos.indexScience Citation Index Expanded (SCI-EXPANDED)