A case study comparing seismic retrofitting techniques for a historically significant masonry building's minaret

MakaleAçık ErişimScopus SJRQ1
  • SDG 9 · Sanayi, Yenilikçilik ve Altyapı
  • SDG 11 · Sürdürülebilir Şehirler ve Topluluklar

Özet

Historical masonry structures are extremely susceptible to earthquakes due to their characteristic features. Seismic performance and corresponding damage patterns vary between these buildings. Even though the main structure was undamaged, many minarets suffered damage or collapsed due to the transmission of large forces from the main mass to the minaret and the abrupt changes in cross-section due to the geometry of the minaret. This study uses an ancient masonry mosque as a case study, whose minaret and main building are constructed as a single structure. The mosque's minaret under seismic excitation is the focus of this study. The adopted model is called Alaeddin Bey Mosque in Muş, Türkiye. The seismic performance assessment of the minaret, considering various retrofitting options, is mainly based on four critical parameters: base shear, acceleration, displacement, and maximum tensile forces in all three dimensions. The analyzed retrofitting methods include base isolation located in the basement of the mosque, viscous dampers placed only in the upper part of the minaret, Carbon Fiber-Reinforced Polymer fabric fitted to only the minaret, and steel plates applied to only the minaret. Representative structural models of the mosque have been modelled with SAP2000 software. The main novelty of this study is the use of viscous dampers in the minaret. It is the first time a design methodology has been introduced for viscous damper applications in minarets. This methodology aims to prevent local damage to the minaret due to the forces generated by the dampers, while also considering the constraints of limited internal space within the minaret. The finding of this study shows that viscous damper application yields significantly better results compared to the application of Carbon Fiber-Reinforced Polymer fabric and steel plates. However, although base isolation reduces the tensile stress values throughout the entire mosque to levels well below the material's strength, viscous damper application in the minaret significantly reduces tensile stresses only in the minaret. As a result, viscous dampers are recommended for damage reduction in the minaret only. Otherwise, base isolation should be considered for reducing stress values throughout the entire mosque including the minaret. This study contributes towards the development of new seismic retrofitting methods for historic masonry buildings ‘minaret.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/bayburt/11817Resmi atıflarda kullanılan kalıcı adres
İndeks kayıtları
Kaydın indeks veri tabanlarındaki sayfası (aktarımda alınan kayıt numarasıyla). Erişim, indeksin kendi koşullarına bağlıdır.
Atıflar
Scopus
26
WoS
26
OpenAlex
24
Her kaynağın kendi saydığı toplam atıf; aktarım ve zenginleştirme sırasında alındı.
Tam Kayıt
AlanDeğerDil
dc.contributor.authorKiral, Adnan
dc.contributor.authorErgün, Mustafa
dc.contributor.authorTonyali, Zeliha
dc.contributor.authorArtar, Musa
dc.contributor.authorŞentürk, İdris
dc.date.accessioned2026-10-29T19:08:50.346098493Z
dc.date.available2026-10-29T19:08:50.346098493Z
dc.date.issued2024
dc.description.abstractHistorical masonry structures are extremely susceptible to earthquakes due to their characteristic features. Seismic performance and corresponding damage patterns vary between these buildings. Even though the main structure was undamaged, many minarets suffered damage or collapsed due to the transmission of large forces from the main mass to the minaret and the abrupt changes in cross-section due to the geometry of the minaret. This study uses an ancient masonry mosque as a case study, whose minaret and main building are constructed as a single structure. The mosque's minaret under seismic excitation is the focus of this study. The adopted model is called Alaeddin Bey Mosque in Muş, Türkiye. The seismic performance assessment of the minaret, considering various retrofitting options, is mainly based on four critical parameters: base shear, acceleration, displacement, and maximum tensile forces in all three dimensions. The analyzed retrofitting methods include base isolation located in the basement of the mosque, viscous dampers placed only in the upper part of the minaret, Carbon Fiber-Reinforced Polymer fabric fitted to only the minaret, and steel plates applied to only the minaret. Representative structural models of the mosque have been modelled with SAP2000 software. The main novelty of this study is the use of viscous dampers in the minaret. It is the first time a design methodology has been introduced for viscous damper applications in minarets. This methodology aims to prevent local damage to the minaret due to the forces generated by the dampers, while also considering the constraints of limited internal space within the minaret. The finding of this study shows that viscous damper application yields significantly better results compared to the application of Carbon Fiber-Reinforced Polymer fabric and steel plates. However, although base isolation reduces the tensile stress values throughout the entire mosque to levels well below the material's strength, viscous damper application in the minaret significantly reduces tensile stresses only in the minaret. As a result, viscous dampers are recommended for damage reduction in the minaret only. Otherwise, base isolation should be considered for reducing stress values throughout the entire mosque including the minaret. This study contributes towards the development of new seismic retrofitting methods for historic masonry buildings ‘minaret.
dc.identifier.articlenumber108873
dc.identifier.doi10.1016/j.engfailanal.2024.108873
dc.identifier.eissn1873-1961
dc.identifier.issn1350-6307
dc.identifier.scopus2-s2.0-85203872534
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/bayburt/11817
dc.identifier.volume166
dc.identifier.wosWOS:001314099200001
dc.language.isoen
dc.publisherElsevier Ltd
dc.relation.ispartofEngineering Failure Analysis
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectBase isolation
dc.subjectDamper force optimization
dc.subjectFEM
dc.subjectMasonry building's minaret
dc.subjectNovel design methodology
dc.subjectSeismic retrofitting techniques
dc.subjectViscous damper
dc.subject.classificationEngineering, Mechanical
dc.subject.classificationMaterials Science, Characterization & Testing
dc.subject.classificationEngineering
dc.subject.classificationMaterials Science
dc.subject.otherBuildings
dc.subject.otherCarbon fiber reinforced plastics
dc.subject.otherConcrete mixtures
dc.subject.otherConcrete products
dc.subject.otherDynamic response
dc.subject.otherEarthquakes
dc.subject.otherMortar
dc.subject.otherSeismic design
dc.subject.otherSeismic response
dc.subject.otherStructural dynamics
dc.subject.otherBase isolation
dc.subject.otherDamper force
dc.subject.otherDamper force optimization
dc.subject.otherForce optimization
dc.subject.otherMasonry building
dc.subject.otherMasonry building minaret
dc.subject.otherNovel design methodology
dc.subject.otherSeismic retrofitting
dc.subject.otherSeismic retrofitting technique
dc.subject.otherViscous dampers
dc.subject.otherRetrofitting
dc.titleA case study comparing seismic retrofitting techniques for a historically significant masonry building's minaret
dc.typeArticle
rdl.citation.openalex24
rdl.citation.scopus26
rdl.citation.wos26
rdl.oa.statusclosed
rdl.oa.statusgreen
rdl.oa.urlhttp://hdl.handle.net/20.500.12403/2892
rdl.scopus.quartileQ1
rdl.sdgSDG11
rdl.sdgSDG09
rdl.source.indexSCOPUS
rdl.source.indexWOS
rdl.wos.indexScience Citation Index Expanded (SCI-EXPANDED)