  • MakaleAçık Erişim2025Scopus SJRQ1
    Investigation of environmental effects through long-term vibration monitoring on the structural behavior and seismic performance assessment of the Hagia Sophia Bell Tower

    Yanik, Yusuf; Türker, Temel; Öztürk, Hasan Tahsin; Demirtaş, Betül; Aymelek, Abdullah; Yildirim, Ömer; Çalik, İsmet

    This study presents development and application of a high-precision, multi-channel vibration measurement system to monitor structural behavior of Hagia Sophia Bell Tower. The research focused on assessing the dynamic characteristics of the tower, both through experimental measurements and numerical simulations. The study began by conducting an in-depth analysis of the tower's dynamic properties using finite element (FE) models, enabling the identification of experimental frequencies. Long-term monitoring was carried out using the newly developed vibration measurement system, complemented by a digital sensor that enabled simultaneous recording of environmental conditions such as temperature and humidity. These parameters were continuously monitored to assess their potential impact on the frequencies and dynamic responses of the tower. Subsequently, regression analyses were performed to establish the relationship between environmental factors, and the tower's structural behavior. The experimental data were used to update FE models, ensuring a more accurate representation of the tower's actual behavior under varying conditions. Earthquake analyses were also conducted on the FE models to evaluate the seismic performance. The results of the study confirmed that vibration testing, combined with environmental monitoring, was a highly effective method for detecting changes in structural behavior. The findings highlighted the significant influence of environmental factors on the dynamic characteristics, with frequency variations reaching an average of 3.6%. These effects should be considered in ongoing monitoring. It was demonstrated that updating FE models reduced numerical errors below 2.5%. These findings gave importance of integrating long-term monitoring with FE model updating, providing more accurate protection and assessment strategies.

    • SDG 9 · Sanayi, Yenilikçilik ve Altyapı
    AtıfScopus4WoS4OpenAlex4
    ScopusWeb of Scienceİncele
  • MakaleAçık Erişim2024Scopus SJRQ1
    A case study comparing seismic retrofitting techniques for a historically significant masonry building's minaret

    Kiral, Adnan; Ergün, Mustafa; Tonyali, Zeliha; Artar, Musa; Şentürk, İdris

    Historical masonry structures are extremely susceptible to earthquakes due to their characteristic features. Seismic performance and corresponding damage patterns vary between these buildings. Even though the main structure was undamaged, many minarets suffered damage or collapsed due to the transmission of large forces from the main mass to the minaret and the abrupt changes in cross-section due to the geometry of the minaret. This study uses an ancient masonry mosque as a case study, whose minaret and main building are constructed as a single structure. The mosque's minaret under seismic excitation is the focus of this study. The adopted model is called Alaeddin Bey Mosque in Muş, Türkiye. The seismic performance assessment of the minaret, considering various retrofitting options, is mainly based on four critical parameters: base shear, acceleration, displacement, and maximum tensile forces in all three dimensions. The analyzed retrofitting methods include base isolation located in the basement of the mosque, viscous dampers placed only in the upper part of the minaret, Carbon Fiber-Reinforced Polymer fabric fitted to only the minaret, and steel plates applied to only the minaret. Representative structural models of the mosque have been modelled with SAP2000 software. The main novelty of this study is the use of viscous dampers in the minaret. It is the first time a design methodology has been introduced for viscous damper applications in minarets. This methodology aims to prevent local damage to the minaret due to the forces generated by the dampers, while also considering the constraints of limited internal space within the minaret. The finding of this study shows that viscous damper application yields significantly better results compared to the application of Carbon Fiber-Reinforced Polymer fabric and steel plates. However, although base isolation reduces the tensile stress values throughout the entire mosque to levels well below the material's strength, viscous damper application in the minaret significantly reduces tensile stresses only in the minaret. As a result, viscous dampers are recommended for damage reduction in the minaret only. Otherwise, base isolation should be considered for reducing stress values throughout the entire mosque including the minaret. This study contributes towards the development of new seismic retrofitting methods for historic masonry buildings ‘minaret.

    • SDG 9 · Sanayi, Yenilikçilik ve Altyapı
    • SDG 11 · Sürdürülebilir Şehirler ve Topluluklar
    AtıfScopus26WoS26OpenAlex24
    ScopusWeb of Scienceİncele
  • MakaleYalnız künye2024Scopus SJRQ1
    Evaluation of the seismic performance pre- and post-restoration of a masonry clock tower's FE model updated via experimental and optimization methods

    Ergün, Mustafa; Tayfur, Bilal

    This article presents comprehensive numerical and partial experimental studies to determine the seismic performance of the recently restored masonry clock tower in Bayburt before and after restoration. The numerical dynamic characteristics of the structure are obtained by free vibration analysis conducted on the preliminary finite element model, while the experimental ones are determined through ambient vibration testing. The ultimate finite element models reflecting the actual state of the structure pre- and post-restoration are created through a model updating process based on the principle of minimizing the differences between numerical and experimental dynamic properties via the Tabu Search Algorithm. Dynamic analyses of the models are carried out by the mode superposition method in the time domain, using eleven earthquake ground motion records selected considering the tectonic structure of the region and scaled to the design spectrum explicitly established to the site. Seismic responses are evaluated based on displacement, maximum-minimum principal stress, and maximum-minimum principal strain. The maximum principal stress value, the most critical parameter jeopardizing the safety of masonry structures, is 2.069 MPa before the restoration reaches 2.489 MPa, with an increase of approximately 20.3 % after the restoration. Since this value is less than the tensile strength of the masonry material, 3.120 MPa, it is not at a level that poses any risk to the structure. Other structural reactions also remain below the limit values. Therefore, according to today's seismic hazard analysis criteria, it can be said that the clock tower is safe. However, the North Anatolian Fault Zone, with high tectonic activity passing just south of the city, has the potential to produce severe earthquakes that may affect the region in the future. Therefore, it is necessary to periodically monitor the seismic behaviors of the historical masonry structures in Bayburt and take essential precautions based on the results.

    • SDG 9 · Sanayi, Yenilikçilik ve Altyapı
    • SDG 11 · Sürdürülebilir Şehirler ve Topluluklar
    AtıfScopus12WoS11OpenAlex13
    ScopusWeb of Scienceİncele
  • MakaleYalnız künye2022Scopus SJRQ1
    Seismic behavior assessment of historical Alaeddin Bey Mosque and strengthening suggestions by CFRP fabric and steel plate

    Şentürk, İdris; Ergün, Mustafa; Artar, Musa

    In this study, the effects of different strengthening methods that can be applied for earthquake-damaged historical masonry structures on structural performance were investigated. For this purpose, the Historical Alaeddin Bey Mosque in the central district of Muş was modeled in three dimensions according to the macromodeling technique using the finite element method in the SAP2000 program. The earthquake performance of the structure was determined by considering the earthquake-acceleration records of Erzincan, Kocaeli, and Van, respectively. The maximum tensile and compressive stresses in all three directions on the structural elements were taken into account as the earthquake behavior parameters of the structure. According to the earthquake analysis made in the time domain, it was determined that the polygonal pulpit of the minaret was at risk of being damaged under the effect of the Erzincan earthquake, and it has been concluded that this region should be strengthened. The damaged area of the minaret was strengthened by the application of CFRP fabric and steel plate materials (together or separately) in five different ways, from inside and outside and at different distance intervals. The conclusions obtained as a result of the earthquake analyses on the reinforced models were examined, and it was explained in detail with the help of tables and graphics that method would be more effective in strengthening such damages.

    • SDG 9 · Sanayi, Yenilikçilik ve Altyapı
    • SDG 11 · Sürdürülebilir Şehirler ve Topluluklar
    AtıfScopus40WoS39OpenAlex41
    ScopusWeb of Scienceİncele
  • MakaleYalnız künye2019Scopus SJRQ1
    Dynamic analyses of experimentally-updated FE model of historical masonry clock towers using site-specific seismic characteristics and scaling parameters according to the 2018 Turkey building earthquake code

    Genç, Ali Fuat; Ergün, Mustafa; Günaydin, M.; Altunişik, Ahmet Can; Ateş, Şevket; Okur, Fatih Yesevi; Mosallam, Ayman S.

    This paper presents a dynamic analysis considering site-specific seismic characteristics for a masonry clock tower located at the city of Çorum, Turkey according to the new Turkish earthquake code. Finite element model of the tower was modeled using ANSYS software in order to determine numerical dynamic characteristics of the structure such as natural frequencies and mode shapes. Non-destructive experimental measurements were performed to extract the experimental dynamic characteristics. Experimental results were used as a reference parameter for finite element model updating to reflect the current structural behavior of clock tower. Model updating procedure was carried out by changing of initial material properties of structural stone elements, and maximum differences were reduced from 23.44% to 4.90%. Numerical results indicated that displacements have an increasing trend with the height of the clock tower. Furthermore, the maximum displacements occurred at the top point between the values of 18.88 mm to 42.5 mm. Numerical results also showed that both the maximum and minimum principal stresses occurred at the upper body (clock zone) walls and transition segment between the values of 1.08 MPa/2.86 MPa and − 0.87 MPa/−3.00 MPa, respectively. The maximum and minimum principal strains occurred at the upper body (clock zone) walls between the values of 0.65E-3/1.56E-3 and − 0.78E-3/−1.50E-3, respectively. It is also concluded that non-destructive experimental measurement is very useful method to evaluate in-situ structural identification, validate and update the initial finite element model for further analyses.

    • SDG 9 · Sanayi, Yenilikçilik ve Altyapı
    • SDG 11 · Sürdürülebilir Şehirler ve Topluluklar
    AtıfScopus46WoS43OpenAlex51
    ScopusWeb of Scienceİncele
Tam Kayıt
AlanDeğerDil
creativeworkseries.issn1350-6307
dc.date.accessioned2026-10-29T19:08:45.984349114Z
dc.date.available2026-10-29T19:08:45.984349114Z
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/bayburt/11760
dc.publisherElsevier Ltd
dc.rightsinfo:eu-repo/semantics/openAccess
dc.titleEngineering Failure Analysis