Evaluation of the seismic performance pre- and post-restoration of a masonry clock tower's FE model updated via experimental and optimization methods

MakaleYalnız künyeScopus SJRQ1
  • SDG 9 · Sanayi, Yenilikçilik ve Altyapı
  • SDG 11 · Sürdürülebilir Şehirler ve Topluluklar

Özet

This article presents comprehensive numerical and partial experimental studies to determine the seismic performance of the recently restored masonry clock tower in Bayburt before and after restoration. The numerical dynamic characteristics of the structure are obtained by free vibration analysis conducted on the preliminary finite element model, while the experimental ones are determined through ambient vibration testing. The ultimate finite element models reflecting the actual state of the structure pre- and post-restoration are created through a model updating process based on the principle of minimizing the differences between numerical and experimental dynamic properties via the Tabu Search Algorithm. Dynamic analyses of the models are carried out by the mode superposition method in the time domain, using eleven earthquake ground motion records selected considering the tectonic structure of the region and scaled to the design spectrum explicitly established to the site. Seismic responses are evaluated based on displacement, maximum-minimum principal stress, and maximum-minimum principal strain. The maximum principal stress value, the most critical parameter jeopardizing the safety of masonry structures, is 2.069 MPa before the restoration reaches 2.489 MPa, with an increase of approximately 20.3 % after the restoration. Since this value is less than the tensile strength of the masonry material, 3.120 MPa, it is not at a level that poses any risk to the structure. Other structural reactions also remain below the limit values. Therefore, according to today's seismic hazard analysis criteria, it can be said that the clock tower is safe. However, the North Anatolian Fault Zone, with high tectonic activity passing just south of the city, has the potential to produce severe earthquakes that may affect the region in the future. Therefore, it is necessary to periodically monitor the seismic behaviors of the historical masonry structures in Bayburt and take essential precautions based on the results.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/bayburt/11759Resmi atıflarda kullanılan kalıcı adres
İndeks kayıtları
Kaydın indeks veri tabanlarındaki sayfası (aktarımda alınan kayıt numarasıyla). Erişim, indeksin kendi koşullarına bağlıdır.
Atıflar
Scopus
12
WoS
11
OpenAlex
13
Her kaynağın kendi saydığı toplam atıf; aktarım ve zenginleştirme sırasında alındı.
Tam Kayıt
AlanDeğerDil
dc.contributor.authorErgün, Mustafa
dc.contributor.authorTayfur, Bilal
dc.date.accessioned2026-10-29T19:08:45.908031404Z
dc.date.available2026-10-29T19:08:45.908031404Z
dc.date.issued2024
dc.description.abstractThis article presents comprehensive numerical and partial experimental studies to determine the seismic performance of the recently restored masonry clock tower in Bayburt before and after restoration. The numerical dynamic characteristics of the structure are obtained by free vibration analysis conducted on the preliminary finite element model, while the experimental ones are determined through ambient vibration testing. The ultimate finite element models reflecting the actual state of the structure pre- and post-restoration are created through a model updating process based on the principle of minimizing the differences between numerical and experimental dynamic properties via the Tabu Search Algorithm. Dynamic analyses of the models are carried out by the mode superposition method in the time domain, using eleven earthquake ground motion records selected considering the tectonic structure of the region and scaled to the design spectrum explicitly established to the site. Seismic responses are evaluated based on displacement, maximum-minimum principal stress, and maximum-minimum principal strain. The maximum principal stress value, the most critical parameter jeopardizing the safety of masonry structures, is 2.069 MPa before the restoration reaches 2.489 MPa, with an increase of approximately 20.3 % after the restoration. Since this value is less than the tensile strength of the masonry material, 3.120 MPa, it is not at a level that poses any risk to the structure. Other structural reactions also remain below the limit values. Therefore, according to today's seismic hazard analysis criteria, it can be said that the clock tower is safe. However, the North Anatolian Fault Zone, with high tectonic activity passing just south of the city, has the potential to produce severe earthquakes that may affect the region in the future. Therefore, it is necessary to periodically monitor the seismic behaviors of the historical masonry structures in Bayburt and take essential precautions based on the results.
dc.identifier.articlenumber107986
dc.identifier.doi10.1016/j.engfailanal.2024.107986
dc.identifier.eissn1873-1961
dc.identifier.issn1350-6307
dc.identifier.scopus2-s2.0-85185152447
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/bayburt/11759
dc.identifier.volume158
dc.identifier.wosWOS:001171901600001
dc.language.isoen
dc.publisherElsevier Ltd
dc.relation.ispartofEngineering Failure Analysis
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.subjectDynamic characteristics
dc.subjectMasonry structure
dc.subjectModel updating
dc.subjectNondestructive vibration measurement
dc.subjectRestoration
dc.subjectSeismic response
dc.subjectTabu Search Algorithm
dc.subject.classificationEngineering, Mechanical
dc.subject.classificationMaterials Science, Characterization & Testing
dc.subject.classificationEngineering
dc.subject.classificationMaterials Science
dc.subject.otherClocks
dc.subject.otherEarthquakes
dc.subject.otherLearning algorithms
dc.subject.otherNondestructive examination
dc.subject.otherRestoration
dc.subject.otherSeismic design
dc.subject.otherSeismic response
dc.subject.otherSeismic waves
dc.subject.otherTensile strength
dc.subject.otherTime domain analysis
dc.subject.otherVibration analysis
dc.subject.otherDynamics characteristic
dc.subject.otherFE model
dc.subject.otherFinite element modelling (FEM)
dc.subject.otherMasonry structures
dc.subject.otherModel updating
dc.subject.otherNon destructive
dc.subject.otherNondestructive vibration measurement
dc.subject.otherNumerical dynamics
dc.subject.otherSeismic Performance
dc.subject.otherTabu search algorithms
dc.subject.otherFinite element method
dc.titleEvaluation of the seismic performance pre- and post-restoration of a masonry clock tower's FE model updated via experimental and optimization methods
dc.typeArticle
rdl.citation.openalex13
rdl.citation.scopus12
rdl.citation.wos11
rdl.oa.statusclosed
rdl.scopus.quartileQ1
rdl.sdgSDG09
rdl.sdgSDG11
rdl.source.indexSCOPUS
rdl.source.indexWOS
rdl.wos.indexScience Citation Index Expanded (SCI-EXPANDED)