Sürdürülebilir Kalkınma Amaçları
Yayınları
23 →- MakaleAçık Erişim2024Scopus SJRQ3Thermoeconomic Analyses of Heat Pumps
Öztekin, Erman Kadir; Gür, Mehmet Murat; Karaali, Rabi
Recently, the rapid development of technology and the increase in energy costs and needs have made reducing the costs and efficient use of energy and exergy important. The thermoeconomic analysis method, which is the best cost analysis method of energy and exergy, gives the ways to reduce costs and increase efficiency that can be applied a facility. It has been found that the most suitable thermoeconomic solution for winter heating and summer cooling of a facility is a vertical underground source heat pump and the most high-performance working fluid that should be used is R32. If the heating is done with a ground source heat pump instead of electrical energy, 4.25 kW of heating energy will be obtained for each kW of electrical energy given for heating, since the costs are COPIP 4.25. Here the earnings increase by around 325%. In other words, heating costs decrease by around 77.5 percent, that is, from one hundred liras to 22. 5 liras.
AtıfOpenAlex4İncele
- MakaleYayıncıda açık erişim2024Scopus SJRQ1Energy, exergy, environmental, and enviroeconomic (4E) analysis of cascade vapor compression refrigeration systems using nanorefrigerants
Yılmaz, Metin; Cimşit, Canan; Keven, Arzu; Karaali, Rabi
The refrigerants used in traditional vapor compression refrigeration systems are harmful to the ozone layer and contribute to global warming. The demand for refrigeration is increasing because of global warming. In this study, for the first time, an energy, exergy, environmental, and enviroeconomic (4E) analysis was performed using different refrigerants and nanoparticles to reduce the energy required in low-temperature vapor compression cascade refrigeration systems and to determine more environmentally friendly nanorefrigerants. The R290 refrigerant was used for the Low-Temperature Circuit (LTC), while the High-Temperature Circuit (HTC) used RE170, R1234yf, R600, R600a, and R450A refrigerants. The nanoparticles used in the analysis were Al2O3, CNT, CuO, TiO2, ZnO, and SiO2. The R600 nanorefrigerant performed the best, whereas the R1234yf nanorefrigerant performed the worst. The results indicate that the CuO nanoparticles provided the highest performance. In addition, the results showed that the R290+R600-CuO nanorefrigerant emitted 11 % less CO2 than the pure R290+R600 refrigerant. The nanorefrigerants provide a more environmentally sustainable option because of their high efficiency and lower energy consumption than conventional refrigerants.
AtıfScopus9WoS7OpenAlex8İncele
- MakaleAçık Erişim2024Scopus SJRQ1Analysis of cascade vapor compression refrigeration system using nanorefrigerants: Energy, exergy, and environmental (3E)
Yilmaz, Metin; Cimsit, Canan; Keven, Arzu; Karaali, Rabi
Nanorefrigerants are considered the most efficient heat transfer fluids for improving heat transfer properties in the refrigeration and air conditioning equipment. For the first time in this study, energy, exergy, and environmental evaluation (3E) analyses were performed by the addition of different nanoparticles to a low GWP refrigerant pair such as R290/R1233ZDE in a cascade refrigeration system. CNT, CuO, and, TiO2 nanoparticles were added to the refrigerant. The effect of nanoparticles on the cascade refrigeration system was analyzed using a model based on density changes. A detailed thermodynamic analysis was performed of the cascade refrigeration system at different evaporator temperatures and mass ratios. The power consumption of the compressor decreases as the evaporator temperature increases for all types of nanoparticles, resulting in an increase in COP values. The analyses showed that CuO nanoparticles had the highest performance. It has been observed that the energy and exergy efficiency increase as compressor work decreases with increasing mass ratios in all nanorefrigerants. In addition, the results indicated that all nanorefrigerants emit lower monthly CO2 emissions compared to the pure refrigerants. The nanorefrigerants play a crucial role in reducing energy consumption and promoting environmental protection compared to traditional refrigerants.
AtıfScopus16WoS16OpenAlex17İncele
- MakaleAçık Erişim2024Scopus SJRQ3Exergetic Analyses of Detonation Engine Cogeneration Plants
Çakmak, Bahar; Karaali, Rabi
Efficiency improvements are very important in all research and technology. Detonation engines are high technology devices. In the last decades they attracted attention by many researchers. However, detonation engines for cogeneration are not researched efficiently. This article is about the detonation engines cogeneration cycles which analysed by using 1. and 2. law of thermodynamics and exergy analyses methods by the authors. The exergetic performance analyses, their advantage and disadvantages of the ZND-HRSG detonation engine cogeneration cycles were obtained. The exergetic performance analyses were done for various excess air rates to obtain the variations of the combustion exit pressures and temperatures, exergy efficiencies, electric heat rates, SFC and other parameters of their performance. Also, an optimization analysis was done for the ZND-HRSG by searching the optimum values for different excess air rates. The results showed that, the ZND-HRSG cycle have the optimum values of the performance at 1.6-1.8 of the excess air rates.
AtıfScopus1OpenAlex5
İncele - MakaleYalnız künye2023Exergetic Analyses of Hypersonic Flows
Topal, Esra Nur; Karaali, Rabi
Hypersonic devices and vehicles and hypersonic flows are very important and competitive advanced technology in science and in the World. Hypersonic technology is rapidly spreading and turning into competition in developed countries, especially in space studies and defense industry. This technology is vital for developed countries. Because of shock waves emerging in hypersonic devices during hypersonic flow, the energy and exergy destructions they cause are the most important difficulties, obstacles and problems which arise in this vital technology. To overcome these problems and difficulties, to prevent or reduce or minimize energy and exergy destruction, aerodynamic analysis and energy and exergy analysis methods are applied. The data and the results that can be guiding and useful for the calculations and the design have been obtained. In this study optimal design and optimum calculations ways of the energy and exergy destructions of hypersonic devices and instruments are discussed. It is obtained and shown that how much exergy destruction and entropy production occurs at which altitude and hypersonic velocities and also at which oblique shock angles.
AtıfScopus2
İncele - MakaleAçık Erişim2023Performance Analyses of Combined Cycle Power Plants
Karaali, Rabi
In this article, different compressor pressure and different excess air rates for a gas turbine based combine cycle power plant with steam Rankine cycle as bottoming cycle were analyzed by using 1. and 2. laws of thermodynamics and exergy analyses methods to obtain the best performances of the cycle. Exergy efficiency of the cycle, net powers of the gas and steam turbines and the overall cycle, exergy loss of the components, the efficiencies of the components are obtained, compared and discussed. It was found that, increasing the compressor pressure increases exergy efficiency of cycle, gas turbine and total plant power, and the combustion chamber, the HRSG and the compressor efficiencies. However, increasing compression rates decreases steam turbine power, combustion chamber, steam turbine, and HRSG exergy losses and the gas turbine efficiency. Also, it is found that, increases in excess air ratios gives an optimum or a maximum exergy efficiency, at 2.5 excess air rate of the cycle.
AtıfScopus3OpenAlex6
İncele - MakaleYalnız künye2022Analysis of Some Tribological Properties of Hazelnut Oil in Gasoline Engines
Keven, Arzu; Karaali, Rabi
In this article, oil obtained from vegetable was used to lubricate a single-cylinder 2-stroke gasoline engine as lubricating oil, and tribological function of the obtained oil was investigated. To investigate the tribological functions of the lubricating oils, a 2-stroke single-cylinder gasoline engine was used. For mineral oil and hazelnut oil, the test engine was run for 100 hours for each one and were used to lubricate in the test engine as lubricating oils. Samples were prepared for the aim of the determining the wear on the cylinder surface, and also EDS (Energy Dispersive Spectrograph) analysis were obtained. The results of the analyses showed that, the wear on the cylinder surface were increased in the studies using hazelnut oil and the C content of the cylinder sample increased compared to the study with mineral oil. Al element was detected in the cylinder sample in the hazelnut study, that the reason for this, is the transport of the Al element during the friction event in the piston material to the cylinder surface.
AtıfOpenAlex1TR Dizin2
İncele - MakaleAçık Erişim2022Scopus SJRQ2Investigation of inlet air pressure and evaporative cooling of four different cogeneration cycles
Karaali, Rabi
The objective of this study was to search the effects of the inlet air compressor pressure and evaporative cooling of four different cogeneration plants that are absorption cooling (ab), basic (bsc), air heating (airh), and air fuel heating (airfh) cogeneration systems by using the first law and the second law of thermodynamics, and the exergy analysis methods. For analysis, a program is written by the author in the FORTRAN programming language. Decreasing the atmospheric pressure or increasing the installation altitude of the plants increases the Z factor (ratio of lost exergy to useful exergy) of the four cycles about 10-13%. Also, decreasing inlet air pressure decreases the specific work about 25-28%, and the fuel energy saving ratio of the four cycles decreases about 29-30%. The method of water spray cooling of the compressor inlet air especially in the summer months, the humidity increases and the evaporative cooling can be obtained. By using this method, the ratio of lost exergy to useful exergy can be decreased for the four cycles about 0.5-2%. Also, the specific work of the four cycles can be increased about 1.2-6%.
AtıfOpenAlex4İncele
- MakaleAçık Erişim2022Scopus SJRQ3Evaluation of four different cogeneration cycles by using some criteria
Karaali, Rabi; Keven, Arzu
The purpose of this article is to evaluate four different gas turbine cogeneration cycles which are basic, absorption cooling, air heating and air fuel heating cogeneration cycles by using the most important six evaluation criteria for different excess air coefficient, different compression rates, and different compressor inlet air temperatures. These six evaluation criteria are electrical heat ratio, exergy efficiency, incremental heat rate, artificial thermal efficiency, fuel energy saving ratio, and specific fuel consumption. It is seen that the air-fuel heating cogeneration cycle is the most efficient among the cycles examined for a certain compressor compression ratio, followed by the air heating, basic, and absorption cooling cycles.
AtıfScopus20WoS18OpenAlex30İncele
- MakaleAçık Erişim2022Scopus SJRQ3Exergy analyses of two and three stage cryogenic cycles
Atasbak, Musa; Keven, Arzu; Karaali, Rabi
Cryogenics has an important influence on industry and science. In this study, optimum working conditions are obtained by applying exergy analysis and local optimization methods to two- and three-stage vapor compression cascade cryogenic cycle. The first and second laws of thermodynamics, exergy analysis, and local optimization methods are applied to the two- and three-stage cascade cryogenic cycle. By considering the needs and demands, it is possible to create new cycles by adding new devices and/or new stages to these cycles. The results of the optimum operating conditions are obtained for the two- and three-stage vapor compression cascade cryogenic cycle. It is seen that to achieve high COP values and high efficiency; it is necessary to reduce the compression ratio of the compressor as much as the fluid allows. For the two-stage cycle, the minimum total work required for cryogenic cooling is around P 7 = 2,400 kPa. The COP value is 0.30 between P 7 = 2,400 and 2,800 kPa, and the maximum exergy efficiency is obtained around 0.235. It is seen operating the first-stage compressor at high pressures increases the total losses of the entire cycle from 7,500 to 18,550 kW. The increase in total exergy losses is around 247%, and operating the first-stage compressor at high pressures increases the exergy efficiency of the entire cycle. The increase in total exergy efficiency is around 160%. When the second-stage compressor is operated at low pressure, the COP value increases by 2%, the exergy efficiency increases by 20%, and the exergy losses decrease by around 40%.
AtıfScopus6WoS3OpenAlex9İncele
Tam Kayıt
| Alan | Değer | Dil |
|---|---|---|
| dc.date.accessioned | 2026-10-29T19:08:34.389804593Z | |
| dc.date.available | 2026-10-29T19:08:34.389804593Z | |
| dc.identifier.uri | https://rdlopen.rawdatalibrary.net/r/bayburt/11592 | |
| dc.rights | info:eu-repo/semantics/openAccess | |
| dc.title | Karaali, Rabi | |
| person.affiliation.name | Bayburt University, Engineering Fac., Department of Mechanical Eng, Merkez, Bayburt, Turkey | |
| person.familyName | Karaali | |
| person.givenName | Rabi | |
| person.identifier.scopus | 56488067800 | |
| person.name.variant | Karaali, R. | |
| person.status | unverified |




