Determining errors in force measurements for colloids close to contact

MakaleAçık ErişimScopus SJRQ2

Özet

Due to diffraction patterns in light microscopy, the overlapping of colloid images introduces minor errors in determining particle positions, which affecting the accuracy of observing interactions between colloids near contact. This study quantitatively investigates the errors arising from the overlapping effect in force measurements between two closely positioned colloids using digital video microscopy (DVM). For this aim, computer simulations were conducted to obtain the positions of two optically trapped colloids interacting based on a force model and particle images were generated as a time series using experimental particle intensity profiles for two different particle sizes. These generated images were analyzed using tracking algorithms from the literature and the interaction forces were extracted and compared with theoretical force values. The results demonstrated that diffraction patterns significantly influence the accuracy of particle position detection and interaction force calculations. Large diffraction patterns and intensity fluctuations in an image introduce significant errors. However, these errors can become significantly smaller in the presence of large forces and may therefore be considered negligible.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/bayburt/11525Resmi atıflarda kullanılan kalıcı adres
DOI
https://doi.org/10.1007/s00339-025-08668-8Yayıncı resmi DOI adresi
İndeks kayıtları
Kaydın indeks veri tabanlarındaki sayfası (aktarımda alınan kayıt numarasıyla). Erişim, indeksin kendi koşullarına bağlıdır.
Atıflar
Scopus
0
WoS
0
OpenAlex
0
Her kaynağın kendi saydığı toplam atıf; aktarım ve zenginleştirme sırasında alındı.
Tam Kayıt
AlanDeğerDil
dc.contributor.authorYücel, Harun
dc.date.accessioned2026-10-29T19:08:29.651027377Z
dc.date.available2026-10-29T19:08:29.651027377Z
dc.date.issued2025
dc.description.abstractDue to diffraction patterns in light microscopy, the overlapping of colloid images introduces minor errors in determining particle positions, which affecting the accuracy of observing interactions between colloids near contact. This study quantitatively investigates the errors arising from the overlapping effect in force measurements between two closely positioned colloids using digital video microscopy (DVM). For this aim, computer simulations were conducted to obtain the positions of two optically trapped colloids interacting based on a force model and particle images were generated as a time series using experimental particle intensity profiles for two different particle sizes. These generated images were analyzed using tracking algorithms from the literature and the interaction forces were extracted and compared with theoretical force values. The results demonstrated that diffraction patterns significantly influence the accuracy of particle position detection and interaction force calculations. Large diffraction patterns and intensity fluctuations in an image introduce significant errors. However, these errors can become significantly smaller in the presence of large forces and may therefore be considered negligible.
dc.description.sponsorshipTürkiye Bilimsel ve Teknolojik Araştırma Kurumu, TUBITAK
dc.identifier.articlenumber539
dc.identifier.doi10.1007/s00339-025-08668-8
dc.identifier.eissn1432-0630
dc.identifier.issn0947-8396
dc.identifier.issue7
dc.identifier.scopus2-s2.0-105007457860
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/bayburt/11525
dc.identifier.volume131
dc.identifier.wosWOS:001504285600004
dc.language.isoen
dc.publisherSpringer Science and Business Media Deutschland GmbH
dc.relation.ispartofApplied Physics A: Materials Science and Processing
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectColloid interactions
dc.subjectForce measurement
dc.subjectSimulation
dc.subjectTracking
dc.subject.classificationMaterials Science, Multidisciplinary
dc.subject.classificationPhysics, Applied
dc.subject.classificationMaterials Science
dc.subject.classificationPhysics
dc.subject.otherStrain measurement
dc.subject.otherVelocity measurement
dc.subject.otherColloid interactions
dc.subject.otherDigital video microscopy
dc.subject.otherForce modeling
dc.subject.otherForces measurements
dc.subject.otherInteraction forces
dc.subject.otherModel images
dc.subject.otherOverlapping effect
dc.subject.otherParticle position
dc.subject.otherSimulation
dc.subject.otherTracking
dc.subject.otherForce measurement
dc.titleDetermining errors in force measurements for colloids close to contact
dc.typeArticle
rdl.citation.openalex0
rdl.citation.scopus0
rdl.citation.wos0
rdl.oa.statushybrid
rdl.oa.urlhttps://link.springer.com/content/pdf/10.1007/s00339-025-08668-8.pdf
rdl.scopus.quartileQ2
rdl.source.indexSCOPUS
rdl.source.indexWOS
rdl.wos.indexScience Citation Index Expanded (SCI-EXPANDED)