Sürdürülebilir Kalkınma Amaçları

Yazarlar

  • MakaleYalnız künye2011Scopus SJRQ1
    Modeling of triple concave friction pendulum bearings for seismic isolation of buildings

    Yurdakul, Muhammet; Ates, Sevket

    Seismic isolated building structures are examined in this study. The triple concave friction pendulum (TCFP) is used as a seismic isolation system which is easy to be manufactured and enduring more than traditional seismic isolation systems. In the TCFP, take advantage of weight which pendulum carrying and it's geometry in order to obtain desirable result of seismic isolation systems. These systems offer advantage to buildings which subject to severe earthquake. This is result of damping force of earthquake by means of their internal constructions, which consists of multiple surfaces. As the combinations of surfaces upon which sliding is occurring change, the stiffness and effective friction change accordingly. Additionally, the mentioned the TCFP is modeled as of a series arrangement of the three single concave friction pendulum (SCFP) bearings. A two dimensional- and eight- story of a building with and without isolation system are used in the time history analysis in order to investigate of the effectiveness of the seismic isolation systems on the buildings. Results are compared with each other to emphasize efficiency of the TCFP as a seismic isolation device against the other friction type isolation system like single and double concave surfaces. The values of the acceleration, floor displacement and isolator displacement obtained from the results by using different types of the isolation bearings are compared each other. As a result, the findings show that the TCFP bearings are more effective devices for isolation of the buildings against severe earthquakes.

    • SDG 9 · Sanayi, Yenilikçilik ve Altyapı
    • SDG 11 · Sürdürülebilir Şehirler ve Topluluklar
    AtıfScopus14OpenAlex12
    Scopusİncele
  • BildiriAçık Erişim2011Scopus SJRQ2
    Site-response effects on RC buildings isolated by triple concave friction pendulum bearings

    Ates, Sevket; Yurdakul, Muhammet

    The main object of this study is to evaluate the seismic response effects on a reinforced concrete building isolated by triple concave friction pendulum (TCFP) bearings. The site-response effects arise from the difference in the local soil conditions at the support points of the buildings. The local soil conditions are, therefore, considered as soft, medium and firm; separately. The results on the responses of the isolated building are compared with those of the non-isolated. The building model used in the time history analysis, which is a two-dimensional and eight-storey reinforced concrete building with and without the seismic isolation bearings and/or the local soil conditions, is composed of two-dimensional moment resisting frames for superstructure and of plane elements featuring plane-stress for substructure. The TCFP bearings for isolating the building are modelled as of a series arrangement of the three single concave friction pendulum (SCFP) bearings. In order to investigate the efficiency of both the seismic isolation bearings and the site-response effects on the buildings, the time history analyses are elaborately conducted. It is noted that the site-response effects are important for the isolated building constructed on soft, medium or firm type local foundation soil. The results of the analysis demonstrate that the siteresponse has significant effects on the response values of the structure-seismic isolation-foundation soil system.

    • SDG 9 · Sanayi, Yenilikçilik ve Altyapı
    • SDG 11 · Sürdürülebilir Şehirler ve Topluluklar
    AtıfScopus9OpenAlex7
    Scopusİncele