Modeling of triple concave friction pendulum bearings for seismic isolation of buildings

MakaleYalnız künyeScopus SJRQ1
  • SDG 9 · Sanayi, Yenilikçilik ve Altyapı
  • SDG 11 · Sürdürülebilir Şehirler ve Topluluklar

Özet

Seismic isolated building structures are examined in this study. The triple concave friction pendulum (TCFP) is used as a seismic isolation system which is easy to be manufactured and enduring more than traditional seismic isolation systems. In the TCFP, take advantage of weight which pendulum carrying and it's geometry in order to obtain desirable result of seismic isolation systems. These systems offer advantage to buildings which subject to severe earthquake. This is result of damping force of earthquake by means of their internal constructions, which consists of multiple surfaces. As the combinations of surfaces upon which sliding is occurring change, the stiffness and effective friction change accordingly. Additionally, the mentioned the TCFP is modeled as of a series arrangement of the three single concave friction pendulum (SCFP) bearings. A two dimensional- and eight- story of a building with and without isolation system are used in the time history analysis in order to investigate of the effectiveness of the seismic isolation systems on the buildings. Results are compared with each other to emphasize efficiency of the TCFP as a seismic isolation device against the other friction type isolation system like single and double concave surfaces. The values of the acceleration, floor displacement and isolator displacement obtained from the results by using different types of the isolation bearings are compared each other. As a result, the findings show that the TCFP bearings are more effective devices for isolation of the buildings against severe earthquakes.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/bayburt/14040Resmi atıflarda kullanılan kalıcı adres
DOI
https://doi.org/10.12989/sem.2011.40.3.315Yayıncı resmi DOI adresi
İndeks kayıtları
Kaydın indeks veri tabanlarındaki sayfası (aktarımda alınan kayıt numarasıyla). Erişim, indeksin kendi koşullarına bağlıdır.
Atıflar
Scopus
14
OpenAlex
12
Her kaynağın kendi saydığı toplam atıf; aktarım ve zenginleştirme sırasında alındı.
Tam Kayıt
AlanDeğerDil
dc.contributor.authorYurdakul, Muhammet
dc.contributor.authorAtes, Sevket
dc.date.accessioned2026-10-29T19:11:48.922824388Z
dc.date.available2026-10-29T19:11:48.922824388Z
dc.date.issued2011
dc.description.abstractSeismic isolated building structures are examined in this study. The triple concave friction pendulum (TCFP) is used as a seismic isolation system which is easy to be manufactured and enduring more than traditional seismic isolation systems. In the TCFP, take advantage of weight which pendulum carrying and it's geometry in order to obtain desirable result of seismic isolation systems. These systems offer advantage to buildings which subject to severe earthquake. This is result of damping force of earthquake by means of their internal constructions, which consists of multiple surfaces. As the combinations of surfaces upon which sliding is occurring change, the stiffness and effective friction change accordingly. Additionally, the mentioned the TCFP is modeled as of a series arrangement of the three single concave friction pendulum (SCFP) bearings. A two dimensional- and eight- story of a building with and without isolation system are used in the time history analysis in order to investigate of the effectiveness of the seismic isolation systems on the buildings. Results are compared with each other to emphasize efficiency of the TCFP as a seismic isolation device against the other friction type isolation system like single and double concave surfaces. The values of the acceleration, floor displacement and isolator displacement obtained from the results by using different types of the isolation bearings are compared each other. As a result, the findings show that the TCFP bearings are more effective devices for isolation of the buildings against severe earthquakes.
dc.identifier.doi10.12989/sem.2011.40.3.315
dc.identifier.endpage334
dc.identifier.issn1225-4568
dc.identifier.issue3
dc.identifier.scopus2-s2.0-80755176346
dc.identifier.startpage315
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/bayburt/14040
dc.identifier.volume40
dc.language.isoen
dc.publisherTechno-Press
dc.relation.ispartofStructural Engineering and Mechanics
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.subjectDouble concave friction pendulum
dc.subjectSeismic isolation
dc.subjectsevere earthquake
dc.subjectSingle concave friction pendulum
dc.subjectTriple concave friction pendulum
dc.subject.otherBuildings
dc.subject.otherFriction
dc.subject.otherPendulums
dc.subject.otherFriction Pendulum
dc.subject.otherFriction pendulum bearings
dc.subject.otherSeismic isolation
dc.subject.otherSeismic isolation devices
dc.subject.otherSeismic isolation of buildings
dc.subject.otherSeismic isolation systems
dc.subject.otherSevere earthquakes
dc.subject.otherTime history analysis
dc.subject.otherEarthquakes
dc.titleModeling of triple concave friction pendulum bearings for seismic isolation of buildings
dc.typeArticle
rdl.citation.openalex12
rdl.citation.scopus14
rdl.oa.statusclosed
rdl.scopus.quartileQ1
rdl.sdgSDG11
rdl.sdgSDG09
rdl.source.indexSCOPUS