Sürdürülebilir Kalkınma Amaçları

Yazarlar

  • MakaleAçık Erişim2015Scopus SJRQ2
    Simultaneous separation and preconcentration of Cd(II), Co(II), and Ni(II) ions in environmental samples by carrier element-free coprecipitation method prior to their flame atomic absorption spectrometric determination

    Duran, Celal; Ozdes, Duygu; Akcay, Hakki Turker; Serencam, Huseyin; Tufekci, Mehmet

    ABSTRACT: In the present study, Cd(II), Co(II), and Ni(II) ions were separated and preconcentrated via carrier element-free coprecipitation (CEFC) method by using an organic coprecipitating agent, 1,2-bis-(2-tosyl ethoxy) benzene (BTEB), prior to their flame atomic absorption spectrometric (FAAS) detections. The experimental conditions were optimized in terms of pH of the aqueous solution, BTEB amount, standing time, centrifugation rate and time, and sample volume. Under the optimum experimental conditions, the detection limits for Cd(II), Co(II), and Ni(II) ions were found to be 0.13, 0.67, and 0.46 μg L−1, respectively, and the relative standard deviations for the analyte ions were found to be lower than 4.0%. The accuracy of the method was tested by analyzing certified reference material and spike tests. The method was applied to determine the levels of Cd(II), Co(II), and Ni(II) ions in sea and stream water, macaroni, red lentil, and cracked wheat samples.

    • SDG 6 · Temiz Su ve Sanitasyon
    AtıfScopus17WoS16OpenAlex16
    ScopusWeb of Scienceİncele
  • MakaleAçık Erişim2015Scopus SJRQ3
    Selective separation, preconcentration and determination of Pd(II) ions in environmental samples by coprecipitation with a 1,2,4-triazole derivative

    Ozdes, Duygu; Duran, Celal; Serencam, Huseyin; Sahin, Deniz; Gundogdu, Ali; Soylak, Mustafa

    A simple, sensitive, facile and low cost methodology, combined with flame atomic absorption spectrometry (FAAS), was employed to evaluate the selective separation and preconcentration of Pd(II) ions in environmental samples by using a triazole derivative as an organic coprecipitating agent without a carrier element. The developed method was systematically investigated in different set of experimental parameters that influence the quantitative recovery of Pd(II) ions. The accuracy of the method was tested by analyzing certified reference material and spike tests. The developed coprecipitation procedure has been applied to road dust, anodic slime, industrial electronic waste materials and water samples to determine their Pd(II) levels.

    AtıfScopus12WoS12OpenAlex16
    ScopusWeb of Scienceİncele
  • MakaleYalnız künye2013Scopus SJRQ3
    Application of carrier element free coprecipitation (CEFC) method for determination of Co(II), Cu(II) and Ni(II) ions in food and water samples

    Serencam, Huseyin; Duran, Celal; Ozdes, Duygu; Bektas, Hakan

    A simple and highly sensitive separation and preconcentration procedure, which has minimal impact on the environment, has been developed. The procedure is based on the carrier element free coprecipitation (CEFC) of Co(II), Cu(II), and Ni(II) ions by using 2-{4-[2-(1H-indol-3-yl)ethyl]-3-(4-methylbenzyl)-5-oxo- 4,5-dihydro-1H-1,2,4-triazol- 1-yl}-N'-(pyridin-2-yl methylidene)acetohydrazide (IMOTPA), as an organic coprecipitant. The levels of analyte ions were determined by flame atomic absorption spectrometry (FAAS). The detection limits for Co(II), Cu(II) and Ni(II) ions were found to be 0.40, 0.16 and 0.17 μg L-1, respectively, and the relative standard deviations for the analyte ions were lower than 3.0%. Spike tests and certified reference material analyses were performed to validate the method. The method was successfully applied for the determination of Co(II), Cu(II) and Ni(II) ions levels in sea and stream water as liquid samples and red pepper, black pepper, and peppermint as solid samples.

    AtıfScopus10WoS10
    ScopusWeb of SciencePubMedİncele