An Experimental Study to Determine the Relationship Between Power Factor and Harmonic Distortion in Single-Phase AC Voltage Controller

MakaleAçık Erişim
  • SDG 7 · Erişilebilir ve Temiz Enerji

Özet

This paper deals with the determination of the relationship between the power factor and the harmonic distortion in a single-phase AC (SPAC) voltage controller. The aim of this study is to investigate the change of power factor (PF) and total harmonic distortion (THD) during different phase triggering angles (PTA). Firstly, the advantages of using thyristor instead of triac in single-phase AC voltage controllers operating at high frequencies are mentioned. Secondly, the power factor and total harmonic distortions for single-phase AC voltage controllers are theoretically examined. Finally, the relationship between power factor and total harmonic distortion are demonstrated by both simulation and experimental studies. However, it is monitored that, at lower output voltages, the power factor (PF) is pretty much reduced and total harmonic distortion (THD) is significantly increased.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/bayburt/14843Resmi atıflarda kullanılan kalıcı adres
DOI
https://doi.org/10.35193/bseufbd.647049Yayıncı resmi DOI adresi
İndeks kayıtları
Kaydın indeks veri tabanlarındaki sayfası (aktarımda alınan kayıt numarasıyla). Erişim, indeksin kendi koşullarına bağlıdır.
Atıflar
OpenAlex
0
TR Dizin
0
Her kaynağın kendi saydığı toplam atıf; aktarım ve zenginleştirme sırasında alındı.
Tam Kayıt
AlanDeğerDil
dc.contributor.authorÇorapsız, Muhammed Reşit
dc.contributor.authorKahveci, Hakan
dc.contributor.authorÇorapsız, Muhammed Fatih
dc.date.accessioned2026-10-29T19:19:47.505289046Z
dc.date.available2026-10-29T19:19:47.505289046Z
dc.date.issued2020
dc.description.abstractThis paper deals with the determination of the relationship between the power factor and the harmonic distortion in a single-phase AC (SPAC) voltage controller. The aim of this study is to investigate the change of power factor (PF) and total harmonic distortion (THD) during different phase triggering angles (PTA). Firstly, the advantages of using thyristor instead of triac in single-phase AC voltage controllers operating at high frequencies are mentioned. Secondly, the power factor and total harmonic distortions for single-phase AC voltage controllers are theoretically examined. Finally, the relationship between power factor and total harmonic distortion are demonstrated by both simulation and experimental studies. However, it is monitored that, at lower output voltages, the power factor (PF) is pretty much reduced and total harmonic distortion (THD) is significantly increased.
dc.identifier.doi10.35193/bseufbd.647049
dc.identifier.eissn2458-7575
dc.identifier.endpage318
dc.identifier.issue1
dc.identifier.startpage306
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/bayburt/14843
dc.identifier.volume7
dc.language.isotr
dc.relation.ispartofBilecik Şeyh Edebali Üniversitesi Fen Bilimleri Dergisi
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectMühendislik, Elektrik ve Elektronik
dc.subjectEnerji ve Yakıtlar
dc.titleAn Experimental Study to Determine the Relationship Between Power Factor and Harmonic Distortion in Single-Phase AC Voltage Controller
dc.typeArticle
rdl.citation.openalex0
rdl.citation.trdizin0
rdl.oa.statusgold
rdl.oa.urlhttps://dergipark.org.tr/en/download/article-file/1138305
rdl.sdgSDG07
rdl.source.indexTRDIZIN