Investigation of Mass Transfer of Ozone in Jet Loop Reactor

MakaleAçık ErişimScopus SJRQ2

Özet

Mass transfer of ozone in a jet loop reactor was investigated in this study. Different parameters such as ozone gas concentration, gas flow rate, circulation flow rate, and spray nozzle diameter were examined for their effect on mass transfer. In experiments with ozone gas concentrations ranging from 3.83 to 17.1 g/m3, the KLa values remained unchanged, with an average of 28.7 ± 2.2 h−1. As the ozone gas concentration increased, the saturation values of ozone in the liquid phase also increased. Experiments were carried out with gas flow rates ranging from 50 to 250 L/h in the jet loop reactor, and increasing gas flow rates increased the KLa value up to five times. When the effect of the liquid circulation flow rate was examined for a spray nozzle diameter of 15.5 mm, increasing the flow rate from 40 L/min to 80 L/min increased the KLa value by approximately 41%. However, the power consumed per reactor volume for this process increased 8 times and reached 2.65 kW/m3. KLa values in the JLR vary between 6.1 and 37.3 h−1 depending on operating parameters and it has been concluded that it performs well compared to its counterparts.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/bayburt/13033Resmi atıflarda kullanılan kalıcı adres
DOI
https://doi.org/10.1007/s11814-024-00147-9Yayıncı resmi DOI adresi
İndeks kayıtları
Kaydın indeks veri tabanlarındaki sayfası (aktarımda alınan kayıt numarasıyla). Erişim, indeksin kendi koşullarına bağlıdır.
Atıflar
Scopus
6
WoS
6
OpenAlex
7
Her kaynağın kendi saydığı toplam atıf; aktarım ve zenginleştirme sırasında alındı.
Tam Kayıt
AlanDeğerDil
dc.contributor.authorCengiz, Ibrahim
dc.contributor.authorDeğermenci, Nejdet
dc.contributor.authorYildiz, Ergun
dc.contributor.authorBarlak, Melahat Semin
dc.date.accessioned2026-10-29T19:10:23.055294579Z
dc.date.available2026-10-29T19:10:23.055294579Z
dc.date.issued2024
dc.description.abstractMass transfer of ozone in a jet loop reactor was investigated in this study. Different parameters such as ozone gas concentration, gas flow rate, circulation flow rate, and spray nozzle diameter were examined for their effect on mass transfer. In experiments with ozone gas concentrations ranging from 3.83 to 17.1 g/m3, the KLa values remained unchanged, with an average of 28.7 ± 2.2 h−1. As the ozone gas concentration increased, the saturation values of ozone in the liquid phase also increased. Experiments were carried out with gas flow rates ranging from 50 to 250 L/h in the jet loop reactor, and increasing gas flow rates increased the KLa value up to five times. When the effect of the liquid circulation flow rate was examined for a spray nozzle diameter of 15.5 mm, increasing the flow rate from 40 L/min to 80 L/min increased the KLa value by approximately 41%. However, the power consumed per reactor volume for this process increased 8 times and reached 2.65 kW/m3. KLa values in the JLR vary between 6.1 and 37.3 h−1 depending on operating parameters and it has been concluded that it performs well compared to its counterparts.
dc.description.sponsorshipTürkiye Bilimsel ve Teknolojik Araştırma Kurumu, TÜBİTAK, (107Y298)
dc.description.sponsorshipTürkiye Bilimsel ve Teknolojik Araştırma Kurumu, TÜBİTAK
dc.identifier.doi10.1007/s11814-024-00147-9
dc.identifier.eissn1975-7220
dc.identifier.endpage1053
dc.identifier.issn0256-1115
dc.identifier.issue4
dc.identifier.scopus2-s2.0-85186914769
dc.identifier.startpage1045
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/bayburt/13033
dc.identifier.volume41
dc.identifier.wosWOS:001177764700002
dc.language.isoen
dc.publisherSpringer
dc.relation.ispartofKorean Journal of Chemical Engineering
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectJet loop reactor
dc.subjectOzonation
dc.subjectOzone mass transfer
dc.subject.classificationChemistry, Multidisciplinary
dc.subject.classificationEngineering, Chemical
dc.subject.classificationChemistry
dc.subject.classificationEngineering
dc.subject.otherFlow of gases
dc.subject.otherFlow rate
dc.subject.otherGases
dc.subject.otherMass transfer
dc.subject.otherOzonization
dc.subject.otherSpray nozzles
dc.subject.otherCirculation flow rate
dc.subject.otherGas concentration
dc.subject.otherGas flowrate
dc.subject.otherJet loop reactors
dc.subject.otherLiquid Phase
dc.subject.otherLiquid phasis
dc.subject.otherNozzle diameter
dc.subject.otherOzone gas
dc.subject.otherOzone mass transfer
dc.subject.otherSaturation values
dc.subject.otherOzone
dc.titleInvestigation of Mass Transfer of Ozone in Jet Loop Reactor
dc.typeArticle
rdl.citation.openalex7
rdl.citation.scopus6
rdl.citation.wos6
rdl.oa.statusclosed
rdl.oa.statusgreen
rdl.oa.urlhttp://hdl.handle.net/20.500.12403/3424
rdl.scopus.quartileQ2
rdl.source.indexSCOPUS
rdl.source.indexWOS
rdl.wos.indexScience Citation Index Expanded (SCI-EXPANDED)