Sürdürülebilir Kalkınma Amaçları

Bu dergideki yayınlar

2 →
  • MakaleAçık Erişim2022Scopus SJRQ3
    Evaluation of four different cogeneration cycles by using some criteria

    Karaali, Rabi; Keven, Arzu

    The purpose of this article is to evaluate four different gas turbine cogeneration cycles which are basic, absorption cooling, air heating and air fuel heating cogeneration cycles by using the most important six evaluation criteria for different excess air coefficient, different compression rates, and different compressor inlet air temperatures. These six evaluation criteria are electrical heat ratio, exergy efficiency, incremental heat rate, artificial thermal efficiency, fuel energy saving ratio, and specific fuel consumption. It is seen that the air-fuel heating cogeneration cycle is the most efficient among the cycles examined for a certain compressor compression ratio, followed by the air heating, basic, and absorption cooling cycles.

    • SDG 7 · Erişilebilir ve Temiz Enerji
    • SDG 13 · İklim Eylemi
    AtıfScopus20WoS18OpenAlex30
    ScopusWeb of Scienceİncele
  • MakaleAçık Erişim2022Scopus SJRQ3
    Exergy analyses of two and three stage cryogenic cycles

    Atasbak, Musa; Keven, Arzu; Karaali, Rabi

    Cryogenics has an important influence on industry and science. In this study, optimum working conditions are obtained by applying exergy analysis and local optimization methods to two- and three-stage vapor compression cascade cryogenic cycle. The first and second laws of thermodynamics, exergy analysis, and local optimization methods are applied to the two- and three-stage cascade cryogenic cycle. By considering the needs and demands, it is possible to create new cycles by adding new devices and/or new stages to these cycles. The results of the optimum operating conditions are obtained for the two- and three-stage vapor compression cascade cryogenic cycle. It is seen that to achieve high COP values and high efficiency; it is necessary to reduce the compression ratio of the compressor as much as the fluid allows. For the two-stage cycle, the minimum total work required for cryogenic cooling is around P 7 = 2,400 kPa. The COP value is 0.30 between P 7 = 2,400 and 2,800 kPa, and the maximum exergy efficiency is obtained around 0.235. It is seen operating the first-stage compressor at high pressures increases the total losses of the entire cycle from 7,500 to 18,550 kW. The increase in total exergy losses is around 247%, and operating the first-stage compressor at high pressures increases the exergy efficiency of the entire cycle. The increase in total exergy efficiency is around 160%. When the second-stage compressor is operated at low pressure, the COP value increases by 2%, the exergy efficiency increases by 20%, and the exergy losses decrease by around 40%.

    • SDG 7 · Erişilebilir ve Temiz Enerji
    AtıfScopus6WoS3OpenAlex9
    ScopusWeb of Scienceİncele
Tam Kayıt
AlanDeğerDil
creativeworkseries.issn1430-6395
dc.date.accessioned2026-10-29T19:09:10.140248594Z
dc.date.available2026-10-29T19:09:10.140248594Z
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/bayburt/12082
dc.publisherWalter de Gruyter GmbH
dc.rightsinfo:eu-repo/semantics/openAccess
dc.titleApplied Rheology