Foundational Engineering of Artificial Blood Vessels’ Biomechanics: The Impact of Wavy Geometric Designs

MakaleAçık ErişimScopus SJRQ2

Özet

The design of wavy structures and their mechanical implications on artificial blood vessels (ABVs) have been insufficiently studied in the existing literature. This research aims to explore the influence of various wavy geometric designs on the mechanical properties of ABVs and to establish a foundational framework for advancing and applying these designs. Computer-aided design (CAD) and finite element method (FEM) simulations, in conjunction with physical sample testing, were utilized. A geometric model incorporating concave and convex curves was developed and analyzed with a symbolic mathematical tool. Subsequently, a total of ten CAD models were subjected to increasing internal pressures using a FEM simulation to evaluate the expansion of internal areas. Additionally, physical experiments were conducted further to investigate the expansion of ABV samples under pressure. The results demonstrated that increased wave numbers significantly enhance the flexibility of ABVs. Samples with 22 waves exhibited a 45% larger area under 24 kPa pressure than those with simple circles. However, the increased number of waves also led to undesirable high-pressure gradients at elevated pressures. Furthermore, a strong correlation was observed between the experimental outcomes and the simulation results, with a notably low error margin, ranging from 19.88% to 3.84%. Incorporating wavy designs into ABVs can effectively increase both vessel flexibility and the internal area under pressure. Finally, it was found that expansion depending on the wave number can be efficiently modeled with a simple linear equation, which could be utilized in future designs.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/bayburt/11893Resmi atıflarda kullanılan kalıcı adres
DOI
https://doi.org/10.3390/biomimetics9090546Yayıncı resmi DOI adresi
İndeks kayıtları
Kaydın indeks veri tabanlarındaki sayfası (aktarımda alınan kayıt numarasıyla). Erişim, indeksin kendi koşullarına bağlıdır.
Atıflar
Scopus
2
WoS
0
OpenAlex
0
Her kaynağın kendi saydığı toplam atıf; aktarım ve zenginleştirme sırasında alındı.
Tam Kayıt
AlanDeğerDil
dc.contributor.authorYilmaz, Galip
dc.date.accessioned2026-10-29T19:08:55.821545349Z
dc.date.available2026-10-29T19:08:55.821545349Z
dc.date.issued2024
dc.description.abstractThe design of wavy structures and their mechanical implications on artificial blood vessels (ABVs) have been insufficiently studied in the existing literature. This research aims to explore the influence of various wavy geometric designs on the mechanical properties of ABVs and to establish a foundational framework for advancing and applying these designs. Computer-aided design (CAD) and finite element method (FEM) simulations, in conjunction with physical sample testing, were utilized. A geometric model incorporating concave and convex curves was developed and analyzed with a symbolic mathematical tool. Subsequently, a total of ten CAD models were subjected to increasing internal pressures using a FEM simulation to evaluate the expansion of internal areas. Additionally, physical experiments were conducted further to investigate the expansion of ABV samples under pressure. The results demonstrated that increased wave numbers significantly enhance the flexibility of ABVs. Samples with 22 waves exhibited a 45% larger area under 24 kPa pressure than those with simple circles. However, the increased number of waves also led to undesirable high-pressure gradients at elevated pressures. Furthermore, a strong correlation was observed between the experimental outcomes and the simulation results, with a notably low error margin, ranging from 19.88% to 3.84%. Incorporating wavy designs into ABVs can effectively increase both vessel flexibility and the internal area under pressure. Finally, it was found that expansion depending on the wave number can be efficiently modeled with a simple linear equation, which could be utilized in future designs.
dc.identifier.articlenumber546
dc.identifier.doi10.3390/biomimetics9090546
dc.identifier.eissn2313-7673
dc.identifier.issn2313-7673
dc.identifier.issue9
dc.identifier.pmcidPMC11430736
dc.identifier.pmid39329568
dc.identifier.scopus2-s2.0-85205110237
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/bayburt/11893
dc.identifier.volume9
dc.identifier.wosWOS:001322972300001
dc.language.isoen
dc.publisherMultidisciplinary Digital Publishing Institute (MDPI)
dc.relation.ispartofBiomimetics
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectartificial blood vessels
dc.subjectbiomechanical engineering
dc.subjectelasticity in artificial vessels
dc.subjectfinite element method
dc.subjecthyperelastic materials
dc.subjectwavy geometric design
dc.subject.classificationEngineering, Multidisciplinary
dc.subject.classificationMaterials Science, Biomaterials
dc.subject.classificationEngineering
dc.subject.classificationMaterials Science
dc.subject.otherMECHANICAL-PROPERTIES
dc.subject.otherVASCULAR GRAFTS
dc.subject.otherCOARCTATION
dc.subject.otherAORTA
dc.titleFoundational Engineering of Artificial Blood Vessels’ Biomechanics: The Impact of Wavy Geometric Designs
dc.typeArticle
rdl.citation.openalex0
rdl.citation.scopus2
rdl.citation.wos0
rdl.departmentElectronics and Automation Department, Bayburt University, Bayburt 69000, Turkey
rdl.oa.statusgold
rdl.oa.statusgreen
rdl.oa.urlhttps://doi.org/10.3390/biomimetics9090546
rdl.scopus.quartileQ2
rdl.source.indexSCOPUS
rdl.source.indexWOS
rdl.source.indexPUBMED
rdl.wos.indexScience Citation Index Expanded (SCI-EXPANDED)