Correlation Between K-value, Density Index and Bifilm Index in Determination of Liquid Al Cleanliness

MakaleAçık ErişimScopus SJRQ3

Özet

Aluminum alloys are widely used in the industry thanks to its many advantages such as light weight and high strength. The use of this material in the market is increasing day by day with the developing technology. Due to the high energy inputs in the primary production, the use of secondary ingots by recycling from scrap material are more advantageous. However, the liquid metal quality is quite important in the use of secondary aluminum. It is believed that the quality of recycled aluminum is low, for this purpose, many liquid metal cleaning methods and test methods are used in the industry to assess the melt cleanliness level. In this study, it is aimed to examine the liquid metal quality in castings with varying temperature using K mold. A206 alloy was used, and the test parameters were selected as: (i) at 725 °C, 750 °C and 775 °C casting temperatures, (ii) different hydrogen levels. The hydrogen level was adjusted as low, medium and high with degassing, as-cast, and upgassing of the melt, respectively. The liquid metal quality of the cast samples was examined by the K mold technique. When the results were examined, it was determined that metal K values and the number of inclusions were high at the as-cast and up-gas liquid with increasing casting temperatures. It has been understood that the K mold technique is a practical method for the determination of liquid metal quality, if there is no reduced pressure test machine available at the foundry floor.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/bayburt/11751Resmi atıflarda kullanılan kalıcı adres
DOI
https://doi.org/10.24425/afe.2023.144311Yayıncı resmi DOI adresi
İndeks kayıtları
Kaydın indeks veri tabanlarındaki sayfası (aktarımda alınan kayıt numarasıyla). Erişim, indeksin kendi koşullarına bağlıdır.
Atıflar
Scopus
7
WoS
6
OpenAlex
7
Her kaynağın kendi saydığı toplam atıf; aktarım ve zenginleştirme sırasında alındı.
Tam Kayıt
AlanDeğerDil
dc.contributor.authorTigli, A.
dc.contributor.authorTokatli, M.
dc.contributor.authorUslu, E.
dc.contributor.authorColak, M.
dc.contributor.authorDispinar, D.
dc.date.accessioned2026-10-29T19:08:45.366123144Z
dc.date.available2026-10-29T19:08:45.366123144Z
dc.date.issued2023
dc.description.abstractAluminum alloys are widely used in the industry thanks to its many advantages such as light weight and high strength. The use of this material in the market is increasing day by day with the developing technology. Due to the high energy inputs in the primary production, the use of secondary ingots by recycling from scrap material are more advantageous. However, the liquid metal quality is quite important in the use of secondary aluminum. It is believed that the quality of recycled aluminum is low, for this purpose, many liquid metal cleaning methods and test methods are used in the industry to assess the melt cleanliness level. In this study, it is aimed to examine the liquid metal quality in castings with varying temperature using K mold. A206 alloy was used, and the test parameters were selected as: (i) at 725 °C, 750 °C and 775 °C casting temperatures, (ii) different hydrogen levels. The hydrogen level was adjusted as low, medium and high with degassing, as-cast, and upgassing of the melt, respectively. The liquid metal quality of the cast samples was examined by the K mold technique. When the results were examined, it was determined that metal K values and the number of inclusions were high at the as-cast and up-gas liquid with increasing casting temperatures. It has been understood that the K mold technique is a practical method for the determination of liquid metal quality, if there is no reduced pressure test machine available at the foundry floor.
dc.identifier.doi10.24425/afe.2023.144311
dc.identifier.eissn2299-2944
dc.identifier.endpage29
dc.identifier.issn1897-3310
dc.identifier.issue3
dc.identifier.scopus2-s2.0-85175448766
dc.identifier.startpage22
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/bayburt/11751
dc.identifier.volume23
dc.identifier.wosWOS:001044254400001
dc.language.isoen
dc.publisherPolska Akademia Nauk
dc.relation.ispartofArchives of Foundry Engineering
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectA206 aluminum casting
dc.subjectK mold
dc.subjectLiquid metal cleaning
dc.subjectRPT
dc.subjectSecondary aluminum
dc.subject.classificationMetallurgy & Metallurgical Engineering
dc.subject.otherAluminum alloys
dc.subject.otherAluminum castings
dc.subject.otherHigh strength alloys
dc.subject.otherHydrogen
dc.subject.otherMolds
dc.subject.otherRecycling
dc.subject.otherScrap metal
dc.subject.otherScrap metal reprocessing
dc.subject.otherA206 aluminum casting
dc.subject.otherAs-cast
dc.subject.otherCasting temperatures
dc.subject.otherHydrogen level
dc.subject.otherK mold
dc.subject.otherK-values
dc.subject.otherLiquid metal cleaning
dc.subject.otherLiquid metal quality
dc.subject.otherRPT
dc.subject.otherSecondary aluminum
dc.subject.otherLiquid metals
dc.titleCorrelation Between K-value, Density Index and Bifilm Index in Determination of Liquid Al Cleanliness
dc.typeArticle
rdl.citation.openalex7
rdl.citation.scopus7
rdl.citation.wos6
rdl.oa.statusgold
rdl.oa.urlhttps://journals.pan.pl/Content/125960/PDF/AFE%201_2023_01_final.pdf?handler=pdf
rdl.scopus.quartileQ3
rdl.source.indexSCOPUS
rdl.source.indexWOS
rdl.wos.indexEmerging Sources Citation Index (ESCI)