Investigation of neutron and gamma radiation protective characteristics of synthesized quinoline derivatives

MakaleAçık ErişimScopus SJRQ2

Özet

Purpose: Quinoline is formed by various natural compounds, such as alkaloids from the cinchona plant, which exhibit various biological activities, and is an important building material for the development of new drugs. Quinoline can be used in anti-radiation drug development but radiation interaction properties must be determined. Material and methods: In this study, six types of synthesized quinoline derivatives were used. Fast neutron removal cross-section, mean free path, half value layer and transmission number were theoretically determined by using GEometry ANd Tracking 4 and FLUktuierende KAskade simulation codes for neutron shielding. Neutron dose absorption rates were determined using the(241)Am-Be fast neutron source and the Canberra NP series portable BF(3)gas proportional neutron detector. Gamma radiation shielding parameters were determined by using WinXCom and PSY-X/PSD software. Additionally, the genotoxic potentials of the derivatives were assessed by using the Ames/Salmonellabacterial reversion assay. Results and conclusions: Neutron shielding parameters such as removal cross-section, mean free path, half value layer and transmission number were theoretically determined for fast neutrons. To determine neutron absorption capacity of quinoline derivatives, neutron absorption, experiments were conducted. In addition, gamma radiation shielding parameters were calculated such as the mean free path (MFP), mass attenuation coefficient (mu t), half value thickness layer (HVL) and effective atomic number (Zeff) in the energy range of 0.015-15 MeV. The results of the all quinoline derivatives have excellent fast neutron shielding power compared to ordinary concrete. In addition, all quinoline derivatives have been found to have the capacity to attenuate gamma radiation. Moreover, they absorb well in both types of radiation, do not cause secondary radiation, and they are genotoxically safe at the tested concentrations. This study has demonstrated that these products can be used as active ingredients for a drug to be developed against radiation.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/bayburt/10834Resmi atıflarda kullanılan kalıcı adres
İndeks kayıtları
Kaydın indeks veri tabanlarındaki sayfası (aktarımda alınan kayıt numarasıyla). Erişim, indeksin kendi koşullarına bağlıdır.
Atıflar
Scopus
47
WoS
47
OpenAlex
52
Her kaynağın kendi saydığı toplam atıf; aktarım ve zenginleştirme sırasında alındı.
Tam Kayıt
AlanDeğerDil
dc.contributor.authorAygün, Bunyamin
dc.contributor.authorAlaylar, Burak
dc.contributor.authorTurhan, Kadir
dc.contributor.authorSakar, Erdem
dc.contributor.authorKaradayi, Mehmet
dc.contributor.authorAbu Al-Sayyed, Ibrahim
dc.contributor.authorPelit, Emel
dc.contributor.authorGüllüce, Medine
dc.contributor.authorKarabulut, Abdulhalik
dc.contributor.authorTurgut, Zuhal
dc.contributor.authorAlim, Bunyamin
dc.date.accessioned2026-10-29T17:19:32.732363055Z
dc.date.available2026-10-29T17:19:32.732363055Z
dc.date.issued2020-11
dc.description.abstractPurpose: Quinoline is formed by various natural compounds, such as alkaloids from the cinchona plant, which exhibit various biological activities, and is an important building material for the development of new drugs. Quinoline can be used in anti-radiation drug development but radiation interaction properties must be determined. Material and methods: In this study, six types of synthesized quinoline derivatives were used. Fast neutron removal cross-section, mean free path, half value layer and transmission number were theoretically determined by using GEometry ANd Tracking 4 and FLUktuierende KAskade simulation codes for neutron shielding. Neutron dose absorption rates were determined using the(241)Am-Be fast neutron source and the Canberra NP series portable BF(3)gas proportional neutron detector. Gamma radiation shielding parameters were determined by using WinXCom and PSY-X/PSD software. Additionally, the genotoxic potentials of the derivatives were assessed by using the Ames/Salmonellabacterial reversion assay. Results and conclusions: Neutron shielding parameters such as removal cross-section, mean free path, half value layer and transmission number were theoretically determined for fast neutrons. To determine neutron absorption capacity of quinoline derivatives, neutron absorption, experiments were conducted. In addition, gamma radiation shielding parameters were calculated such as the mean free path (MFP), mass attenuation coefficient (mu t), half value thickness layer (HVL) and effective atomic number (Zeff) in the energy range of 0.015-15 MeV. The results of the all quinoline derivatives have excellent fast neutron shielding power compared to ordinary concrete. In addition, all quinoline derivatives have been found to have the capacity to attenuate gamma radiation. Moreover, they absorb well in both types of radiation, do not cause secondary radiation, and they are genotoxically safe at the tested concentrations. This study has demonstrated that these products can be used as active ingredients for a drug to be developed against radiation.
dc.identifier.doi10.1080/09553002.2020.1811421
dc.identifier.eissn1362-3095
dc.identifier.endpage1434
dc.identifier.issn0955-3002
dc.identifier.issue11
dc.identifier.pmid32813583
dc.identifier.scopus2-s2.0-85091074141
dc.identifier.startpage1423
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/bayburt/10834
dc.identifier.volume96
dc.identifier.wosWOS:000569449200001
dc.language.isoen
dc.publisherTAYLOR & FRANCIS LTD
dc.relation.ispartofINTERNATIONAL JOURNAL OF RADIATION BIOLOGY
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectDrugs
dc.subjectgenotoxicity
dc.subjectgamma
dc.subjectneutron
dc.subjectshielding
dc.subjectquinoline derivatives
dc.subject.classificationBiology
dc.subject.classificationNuclear Science & Technology
dc.subject.classificationRadiology, Nuclear Medicine & Medical Imaging
dc.subject.classificationLife Sciences & Biomedicine - Other Topics
dc.subject.otherDIELS-ALDER REACTIONS
dc.subject.otherPARAMETERS
dc.subject.otherREMOVAL
dc.subject.otherNUMBER
dc.subject.otherREGION
dc.titleInvestigation of neutron and gamma radiation protective characteristics of synthesized quinoline derivatives
dc.typeArticle
rdl.citation.openalex52
rdl.citation.scopus47
rdl.citation.wos47
rdl.departmentDepartment of Electronics and Automation, Vocational School, Agri Ibrahim Cecen University, Agri, Turkey
rdl.departmentDepartment of Molecular Biology and Genetics, Faculty of Science and Arts, Agri Ibrahim Cecen University, Agri, Turkey
rdl.departmentDepartment of Chemistry, Faculty of Art and Sciences, Yildiz Technical University, İstanbul, Turkey
rdl.departmentDepartment of Physics, Faculty of Science, Atatürk University, Erzurum, Turkey
rdl.departmentDepartment of Biology, Faculty of Science, Atatürk University, Erzurum, Turkey
rdl.departmentDepartment of Physics, Faculty of Science, University of Tabuk, Tabuk, KSA
rdl.departmentDepartment of Chemistry, Faculty of Art and Sciences, Kirklareli University, Kirklareli, Turkey
rdl.departmentAgri Ibrahim Cecen University, Agri, Turkey
rdl.departmentDepartment of Electricity and Energy, Technical Scientific Vocational School, Bayburt University, Bayburt, Turkey
rdl.oa.statusclosed
rdl.oa.statusgreen
rdl.oa.urlhttp://hdl.handle.net/20.500.12403/3428
rdl.scopus.quartileQ2
rdl.source.indexWOS
rdl.source.indexSCOPUS
rdl.source.indexPUBMED
rdl.wos.indexScience Citation Index Expanded (SCI-EXPANDED)