Relationship between hydraulic and geoelectrical parameters for alluvial aquifers in Bursa, Turkey—a case study

MakaleAçık ErişimScopus SJRQ2
  • SDG 6 · Temiz Su ve Sanitasyon

Özet

This research aims at analyzing the relationship between the hydraulic conductivity and the formation factor in alluvial aquifers. The study was conducted on the alluvial aquifers within the province of Bursa, Turkey. Field surveys were carried out on 12 different locations each having alluvial formation. Initially, slug tests were applied at the wells and hydraulic conductivity values were calculated by using Bouwer-Rice and Dagan analytic methods. Afterwards, vertical electrical sounding method with Schlumberger array was applied on these locations to obtain apparent resistivity. These values were then converted to real resistivity under IPI2WIN software. Water samples were taken from the wells, and their electrical conductivity values were measured in the laboratory which were converted to water resistivity. Finally, formation factor was calculated as a ratio of real resistivity to water resistivity. The variations of hydraulic conductivity and transmissivity values against the formation factor were examined, and a linear relation was observed. Furthermore, their variations against modified formation factor and modified aquifer resistivity were also investigated and similarly linear relationships were observed. The graphs obtained conform to the results of similar studies in literature and will serve as a guideline for prospective groundwater research in the study area.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/bayburt/12042Resmi atıflarda kullanılan kalıcı adres
DOI
https://doi.org/10.1007/s12517-021-08614-xYayıncı resmi DOI adresi
İndeks kayıtları
Kaydın indeks veri tabanlarındaki sayfası (aktarımda alınan kayıt numarasıyla). Erişim, indeksin kendi koşullarına bağlıdır.
Atıflar
Scopus
3
OpenAlex
2
Her kaynağın kendi saydığı toplam atıf; aktarım ve zenginleştirme sırasında alındı.
Tam Kayıt
AlanDeğerDil
dc.contributor.authorEryılmaz Türkkan, Gökçen
dc.contributor.authorKorkmaz, Serdar
dc.date.accessioned2026-10-29T19:09:06.990022809Z
dc.date.available2026-10-29T19:09:06.990022809Z
dc.date.issued2021
dc.description.abstractThis research aims at analyzing the relationship between the hydraulic conductivity and the formation factor in alluvial aquifers. The study was conducted on the alluvial aquifers within the province of Bursa, Turkey. Field surveys were carried out on 12 different locations each having alluvial formation. Initially, slug tests were applied at the wells and hydraulic conductivity values were calculated by using Bouwer-Rice and Dagan analytic methods. Afterwards, vertical electrical sounding method with Schlumberger array was applied on these locations to obtain apparent resistivity. These values were then converted to real resistivity under IPI2WIN software. Water samples were taken from the wells, and their electrical conductivity values were measured in the laboratory which were converted to water resistivity. Finally, formation factor was calculated as a ratio of real resistivity to water resistivity. The variations of hydraulic conductivity and transmissivity values against the formation factor were examined, and a linear relation was observed. Furthermore, their variations against modified formation factor and modified aquifer resistivity were also investigated and similarly linear relationships were observed. The graphs obtained conform to the results of similar studies in literature and will serve as a guideline for prospective groundwater research in the study area.
dc.description.sponsorshipBUSKI
dc.description.sponsorshipBursa Water and Sewerage Administration
dc.identifier.articlenumber2221
dc.identifier.doi10.1007/s12517-021-08614-x
dc.identifier.issn1866-7511
dc.identifier.issue21
dc.identifier.scopus2-s2.0-85117953953
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/bayburt/12042
dc.identifier.volume14
dc.language.isoen
dc.publisherSpringer Science and Business Media Deutschland GmbH
dc.relation.ispartofArabian Journal of Geosciences
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectBouwer-Rice method
dc.subjectDagan method
dc.subjectGeoelectrical methods
dc.subjectIPI2WIN
dc.subjectSlug test
dc.subject.otherBursa [Turkey]
dc.subject.otherTurkey
dc.subject.otherMeleagris gallopavo
dc.subject.otheralluvial deposit
dc.subject.otheraquifer
dc.subject.otherelectrical conductivity
dc.subject.otherfield survey
dc.subject.othergroundwater
dc.subject.otherhydraulic conductivity
dc.subject.otherslug test
dc.subject.othersoftware
dc.subject.othervertical electrical sounding
dc.titleRelationship between hydraulic and geoelectrical parameters for alluvial aquifers in Bursa, Turkey—a case study
dc.typeArticle
rdl.citation.openalex2
rdl.citation.scopus3
rdl.oa.statusclosed
rdl.oa.statusgreen
rdl.oa.urlhttp://hdl.handle.net/20.500.12403/4031
rdl.scopus.quartileQ2
rdl.sdgSDG06
rdl.source.indexSCOPUS