Experimental performance assessment of two-stage thermoelectric system in a closed-cycle drying process

MakaleAçık ErişimScopus SJRQ1
  • SDG 7 · Erişilebilir ve Temiz Enerji
  • SDG 9 · Sanayi, Yenilikçilik ve Altyapı
  • SDG 12 · Sorumlu Üretim ve Tüketim

Özet

Traditional drying systems suffer from several limitations, including high energy consumption, insufficient hygienic control, and the inability to maintain precise temperature regulation. Although alternative drying systems have been developed to address these issues, they often encounter practical challenges due to their complex structures and the need for numerous external components. To overcome these limitations, this study proposes and experimentally evaluates a novel, independently operating, two-stage thermoelectric module (TEM) system integrated into a closed-loop drying setup that eliminates the need for external heating and dehumidification components. The proposed system addresses the efficiency and hygiene problems observed in conventional dryers by simultaneously performing air heating, cooling, and dehumidification functions through compact thermoelectric devices. The drying process consists of two stages: the first involves air pre-conditioning (heating/cooling), while the second is dedicated to dehumidification. The performance of the system has been evaluated based on key metrics such as cooling and heating capacities, the coefficients of performance (COP) for both stages, moisture removal rate (MRR), and moisture removal rate effectiveness (EffMRR). Experimental studies were conducted under input voltages ranging from 3 to 7 V, relative humidity levels between 60 % and 90 %, and varying airflow rates. Under 90 % relative humidity conditions and a 7 V input voltage, the system achieved a maximum moisture removal rate of 13.1 g/h. The first-stage TEM reached a heating capacity of 68.81 W and a cooling capacity of 26.34 W, while the second stage provided 21.17 W of cooling capacity.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/bayburt/10912Resmi atıflarda kullanılan kalıcı adres
İndeks kayıtları
Kaydın indeks veri tabanlarındaki sayfası (aktarımda alınan kayıt numarasıyla). Erişim, indeksin kendi koşullarına bağlıdır.
Atıflar
Scopus
5
WoS
5
OpenAlex
5
Her kaynağın kendi saydığı toplam atıf; aktarım ve zenginleştirme sırasında alındı.
Tam Kayıt
AlanDeğerDil
dc.contributor.authorOsta, Muhammet Harun
dc.contributor.authorYakut, Kenan
dc.contributor.authorKöksal, Hüseyin
dc.date.accessioned2026-10-29T19:07:51.825175935Z
dc.date.available2026-10-29T19:07:51.825175935Z
dc.date.issued2025
dc.description.abstractTraditional drying systems suffer from several limitations, including high energy consumption, insufficient hygienic control, and the inability to maintain precise temperature regulation. Although alternative drying systems have been developed to address these issues, they often encounter practical challenges due to their complex structures and the need for numerous external components. To overcome these limitations, this study proposes and experimentally evaluates a novel, independently operating, two-stage thermoelectric module (TEM) system integrated into a closed-loop drying setup that eliminates the need for external heating and dehumidification components. The proposed system addresses the efficiency and hygiene problems observed in conventional dryers by simultaneously performing air heating, cooling, and dehumidification functions through compact thermoelectric devices. The drying process consists of two stages: the first involves air pre-conditioning (heating/cooling), while the second is dedicated to dehumidification. The performance of the system has been evaluated based on key metrics such as cooling and heating capacities, the coefficients of performance (COP) for both stages, moisture removal rate (MRR), and moisture removal rate effectiveness (EffMRR). Experimental studies were conducted under input voltages ranging from 3 to 7 V, relative humidity levels between 60 % and 90 %, and varying airflow rates. Under 90 % relative humidity conditions and a 7 V input voltage, the system achieved a maximum moisture removal rate of 13.1 g/h. The first-stage TEM reached a heating capacity of 68.81 W and a cooling capacity of 26.34 W, while the second stage provided 21.17 W of cooling capacity.
dc.identifier.articlenumber127451
dc.identifier.doi10.1016/j.applthermaleng.2025.127451
dc.identifier.eissn1873-5606
dc.identifier.issn1359-4311
dc.identifier.scopus2-s2.0-105009694829
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/bayburt/10912
dc.identifier.volume278
dc.identifier.wosWOS:001530509800002
dc.language.isoen
dc.publisherElsevier Ltd
dc.relation.ispartofApplied Thermal Engineering
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectClosed-loop drying
dc.subjectThermoelectric cooling
dc.subjectThermoelectric dehumidifier
dc.subjectThermoelectric heat pump
dc.subjectTwo-stage thermoelectric system
dc.subject.classificationThermodynamics
dc.subject.classificationEnergy & Fuels
dc.subject.classificationEngineering, Mechanical
dc.subject.classificationMechanics
dc.subject.classificationEngineering
dc.subject.otherCoefficient of performance
dc.subject.otherCooling systems
dc.subject.otherDryers (equipment)
dc.subject.otherDrying
dc.subject.otherMoisture
dc.subject.otherThermoelectric equipment
dc.subject.otherThermoelectric refrigeration
dc.subject.otherThermoelectricity
dc.subject.otherClosed-loop
dc.subject.otherClosed-loop drying
dc.subject.otherMoisture removal
dc.subject.otherRemoval rate
dc.subject.otherThermoelectric
dc.subject.otherThermoelectric cooling
dc.subject.otherThermoelectric dehumidifier
dc.subject.otherThermoelectric heat pump
dc.subject.otherThermoelectric systems
dc.subject.otherTwo-stage thermoelectric system
dc.subject.otherEnergy utilization
dc.titleExperimental performance assessment of two-stage thermoelectric system in a closed-cycle drying process
dc.typeArticle
rdl.citation.openalex5
rdl.citation.scopus5
rdl.citation.wos5
rdl.oa.statusclosed
rdl.oa.statusgreen
rdl.oa.urlhttps://hdl.handle.net/20.500.12403/5975
rdl.scopus.quartileQ1
rdl.sdgSDG07
rdl.sdgSDG09
rdl.sdgSDG12
rdl.source.indexSCOPUS
rdl.source.indexWOS
rdl.wos.indexScience Citation Index Expanded (SCI-EXPANDED)