A Taguchi approach for optimization of design parameters in a tube with coiled wire inserts

MakaleYalnız künyeScopus SJRQ1

Özet

This study presents the determination of the optimum values of the design parameters in a tube with equilateral triangular cross-sectioned coiled wire inserts. The effects of the design parameters such as the ratio of the distance between the coiled wire and test tube wall to tube diameter (s/D), pitch ratio (P/D), ratio of the side length of equilateral triangle to tube diameter (a/D) and Reynolds number (Re) on heat transfer and pressure drop were investigated by using Taguchi method. The Nusselt number and friction factor were considered as performance parameters. An L9(34) orthogonal array was chosen as experimental plan. The goal of this study is to reach maximum heat transfer (i.e. Nusselt number) and minimum pressure drop (i.e. friction factor). First of all, each goal was optimized, separately. Then, all the goals were optimized together, considering the priority of the goals. Contribution ratios for each parameter on the heat transfer and pressure drop were determined. Consequently, the optimum results were found to be s/D = 0.0357, P/D = 1, a/D = 0.0714 and Re = 19800.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/bayburt/13988Resmi atıflarda kullanılan kalıcı adres
İndeks kayıtları
Kaydın indeks veri tabanlarındaki sayfası (aktarımda alınan kayıt numarasıyla). Erişim, indeksin kendi koşullarına bağlıdır.
Atıflar
Scopus
115
WoS
100
OpenAlex
113
Her kaynağın kendi saydığı toplam atıf; aktarım ve zenginleştirme sırasında alındı.
Tam Kayıt
AlanDeğerDil
dc.contributor.authorGunes, Sibel
dc.contributor.authorManay, Eyuphan
dc.contributor.authorSenyigit, Ercan
dc.contributor.authorOzceyhan, Veysel
dc.date.accessioned2026-10-29T19:11:44.476600978Z
dc.date.available2026-10-29T19:11:44.476600978Z
dc.date.issued2011
dc.description.abstractThis study presents the determination of the optimum values of the design parameters in a tube with equilateral triangular cross-sectioned coiled wire inserts. The effects of the design parameters such as the ratio of the distance between the coiled wire and test tube wall to tube diameter (s/D), pitch ratio (P/D), ratio of the side length of equilateral triangle to tube diameter (a/D) and Reynolds number (Re) on heat transfer and pressure drop were investigated by using Taguchi method. The Nusselt number and friction factor were considered as performance parameters. An L9(34) orthogonal array was chosen as experimental plan. The goal of this study is to reach maximum heat transfer (i.e. Nusselt number) and minimum pressure drop (i.e. friction factor). First of all, each goal was optimized, separately. Then, all the goals were optimized together, considering the priority of the goals. Contribution ratios for each parameter on the heat transfer and pressure drop were determined. Consequently, the optimum results were found to be s/D = 0.0357, P/D = 1, a/D = 0.0714 and Re = 19800.
dc.description.sponsorshipErciyes Üniversitesi
dc.identifier.doi10.1016/j.applthermaleng.2011.04.022
dc.identifier.endpage2577
dc.identifier.issn1359-4311
dc.identifier.issue14-15
dc.identifier.scopus2-s2.0-79960922912
dc.identifier.startpage2568
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/bayburt/13988
dc.identifier.volume31
dc.identifier.wosWOS:000294089500043
dc.language.isoen
dc.publisherPERGAMON-ELSEVIER SCIENCE LTD
dc.relation.ispartofApplied Thermal Engineering
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.subjectCoiled wire
dc.subjectHeat transfer
dc.subjectOptimization
dc.subjectPressure drop
dc.subjectTaguchi method
dc.subject.classificationThermodynamics
dc.subject.classificationEnergy & Fuels
dc.subject.classificationEngineering, Mechanical
dc.subject.classificationMechanics
dc.subject.classificationEngineering
dc.subject.otherDesign
dc.subject.otherFriction
dc.subject.otherNusselt number
dc.subject.otherOptimization
dc.subject.otherPressure drop
dc.subject.otherReynolds number
dc.subject.otherTaguchi methods
dc.subject.otherWire
dc.subject.otherCoiled wire
dc.subject.otherDesign parameters
dc.subject.otherEquilateral triangles
dc.subject.otherFriction factors
dc.subject.otherHeat transfer and pressure drop
dc.subject.otherMaximum heat transfer
dc.subject.otherMinimum pressure
dc.subject.otherOptimum value
dc.subject.otherOrthogonal array
dc.subject.otherPerformance parameters
dc.subject.otherPitch ratio
dc.subject.otherSide length
dc.subject.otherTaguchi
dc.subject.otherTaguchi approach
dc.subject.otherTest tube
dc.subject.otherTube diameters
dc.subject.otherTubes (components)
dc.titleA Taguchi approach for optimization of design parameters in a tube with coiled wire inserts
dc.typeArticle
rdl.citation.openalex113
rdl.citation.scopus115
rdl.citation.wos100
rdl.oa.statusclosed
rdl.scopus.quartileQ1
rdl.source.indexSCOPUS
rdl.source.indexWOS
rdl.wos.indexScience Citation Index Expanded (SCI-EXPANDED)