Investigation of seismic performance of in-plane aligned masonry panels strengthened with Carbon Fiber Reinforced Polymer

MakaleAçık ErişimScopus SJRQ1
  • SDG 9 · Sanayi, Yenilikçilik ve Altyapı

Özet

Masonry structures are economical, easy to construct and has important advantages such as the use of natural materials. In Turkey, these structures have been heavily built especially with traditional construction methods and nowadays they are popular as well. Therefore, the reinforcement of masonry structures and seismic safety are of paramount importance. Masonry walls are not naturally stable and cannot be considered as homogeneous structures so it is difficult to predict their behavior under load by using numerical methods. Supportive framework of the mathematical model and the data of the experimental studies are required. In this study, 36 wall blocks were prepared in 900 × 900 × 200 mm using hollow masonry brick, blend brick and aerated concrete and these blocks are reinforced with Carbon Fiber Reinforced Polymer in both directions by using three different methods. For the analysis of retrofit brick walls produced and reinforced with different materials, ASTM E591 test method was used. At the end of the experiment period; shear strength performances of the reinforcement methods of the elements, their deformation and energy dissipation capacities were evaluated. According to results, maximum shear strength performance was observed at the masonry panel strengthened by two face. Maximum load value was 172.63 Kn. Also maximum dissipation capacity was observed at the masonry wall reinforced with CFRP covered diagonally. Maximum energy dissipation capacity was 317.1 J.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/bayburt/13821Resmi atıflarda kullanılan kalıcı adres
İndeks kayıtları
Kaydın indeks veri tabanlarındaki sayfası (aktarımda alınan kayıt numarasıyla). Erişim, indeksin kendi koşullarına bağlıdır.
Atıflar
Scopus
32
WoS
26
OpenAlex
34
Her kaynağın kendi saydığı toplam atıf; aktarım ve zenginleştirme sırasında alındı.
Tam Kayıt
AlanDeğerDil
dc.contributor.authorCan, Ömer
dc.date.accessioned2026-10-29T19:11:30.474832236Z
dc.date.available2026-10-29T19:11:30.474832236Z
dc.date.issued2018
dc.description.abstractMasonry structures are economical, easy to construct and has important advantages such as the use of natural materials. In Turkey, these structures have been heavily built especially with traditional construction methods and nowadays they are popular as well. Therefore, the reinforcement of masonry structures and seismic safety are of paramount importance. Masonry walls are not naturally stable and cannot be considered as homogeneous structures so it is difficult to predict their behavior under load by using numerical methods. Supportive framework of the mathematical model and the data of the experimental studies are required. In this study, 36 wall blocks were prepared in 900 × 900 × 200 mm using hollow masonry brick, blend brick and aerated concrete and these blocks are reinforced with Carbon Fiber Reinforced Polymer in both directions by using three different methods. For the analysis of retrofit brick walls produced and reinforced with different materials, ASTM E591 test method was used. At the end of the experiment period; shear strength performances of the reinforcement methods of the elements, their deformation and energy dissipation capacities were evaluated. According to results, maximum shear strength performance was observed at the masonry panel strengthened by two face. Maximum load value was 172.63 Kn. Also maximum dissipation capacity was observed at the masonry wall reinforced with CFRP covered diagonally. Maximum energy dissipation capacity was 317.1 J.
dc.description.sponsorshipScientific Research Unit (BAP)
dc.identifier.doi10.1016/j.conbuildmat.2018.08.028
dc.identifier.eissn1879-0526
dc.identifier.endpage862
dc.identifier.issn0950-0618
dc.identifier.scopus2-s2.0-85051377915
dc.identifier.startpage854
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/bayburt/13821
dc.identifier.volume186
dc.identifier.wosWOS:000445983300073
dc.language.isoen
dc.publisherElsevier Ltd
dc.relation.ispartofConstruction and Building Materials
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectCarbon Fiber Reinforced Polymer (CFRP)
dc.subjectMasonry wall
dc.subjectRetrofit
dc.subjectShear strength
dc.subject.classificationConstruction & Building Technology
dc.subject.classificationEngineering, Civil
dc.subject.classificationMaterials Science, Multidisciplinary
dc.subject.classificationEngineering
dc.subject.classificationMaterials Science
dc.subject.otherBrick
dc.subject.otherConcretes
dc.subject.otherEnergy dissipation
dc.subject.otherFiber reinforced plastics
dc.subject.otherMasonry construction
dc.subject.otherNumerical methods
dc.subject.otherPolymers
dc.subject.otherReinforced plastics
dc.subject.otherReinforcement
dc.subject.otherRetaining walls
dc.subject.otherRetrofitting
dc.subject.otherSeismology
dc.subject.otherShear strength
dc.subject.otherTesting
dc.subject.otherWalls (structural partitions)
dc.subject.otherCarbon fiber reinforced polymer
dc.subject.otherEnergy dissipation capacities
dc.subject.otherHomogeneous structure
dc.subject.otherMasonry walls
dc.subject.otherMaximum dissipations
dc.subject.otherReinforcement method
dc.subject.otherRetrofit
dc.subject.otherTraditional constructions
dc.subject.otherCarbon fiber reinforced plastics
dc.titleInvestigation of seismic performance of in-plane aligned masonry panels strengthened with Carbon Fiber Reinforced Polymer
dc.typeArticle
rdl.citation.openalex34
rdl.citation.scopus32
rdl.citation.wos26
rdl.oa.statusclosed
rdl.oa.statusgreen
rdl.oa.urlhttps://hdl.handle.net/20.500.12403/351
rdl.scopus.quartileQ1
rdl.sdgSDG09
rdl.source.indexSCOPUS
rdl.source.indexWOS
rdl.wos.indexScience Citation Index Expanded (SCI-EXPANDED)