Bu dergideki yayınlar

2 →
  • MakaleAçık Erişim2021Scopus SJRQ1
    Measurement of Propagation Characteristics of Nonreciprocal Networks/Lines Using a Line-Line Method

    Hasar, Ugur C.; Kaya, Yunus; Ertugrul, Mehmet

    In this article have proposed a new calibration-free line-line method for propagation constant (gamma) determination of homogeneous nonreciprocal networks or lines with symmetric reflection property. To achieve our goal, wave-cascading matrices for impedance, amplitude, and phase changes for a line step from a homogeneous reciprocal network or line to a homogeneous nonreciprocal network or line (and vice versa). Two different approaches based on the proposed line-line method are proposed for unique extraction of gamma in forward and backward directions. Measurements of gamma for two reciprocal lines (waveguide straights at X-band and Ku-band with different lengths) and a nonreciprocal line (microwave phase shifter) were first carried out and then compared with measured gamma of these lines by different methods to validate our method and monitor its accuracy.

    AtıfWoS4OpenAlex5
    Web of Scienceİncele
  • MakaleAçık Erişim2018Scopus SJRQ1
    Self-Calibrating Noniterative Complex Permittivity Extraction of Thin Dielectric Samples

    Hasar, Ugur Cem; Kaya, Yunus

    A microwave method relying on uncalibrated scattering (S-) parameters is proposed to measure the complex permittivity (ϵr) of thin dielectric samples. It has the following two main advantages. First, it takes into account effect of the sample holder, used for holding the sample, especially important for thin sample electromagnetic property characterization. Second, it does not require any specific information about the location of the sample (and its holder) inside its measurement cell for ϵr extraction. For validation of our method, we applied a commercial three-dimensional electromagnetic simulation program-CST Microwave Studio-and the Lorentz dispersion model. Uncalibrated (as well as calibrated) S-parameter measurements were conducted to measure ϵr of a 0.7 mm thick polyethylene sample (the sample holder was a 5.18 mm thick PVC sample) by our method and other similar methods in the literature. From the comparison, we observed that while the accuracy of tested methods significantly changed with inaccurate knowledge of the sample position inside its cell, the accuracy of our method did not much alter.

    AtıfScopus18WoS16OpenAlex18
    ScopusWeb of Scienceİncele
Tam Kayıt
AlanDeğerDil
creativeworkseries.issn0018-9375
dc.date.accessioned2026-10-29T19:11:18.124741811Z
dc.date.available2026-10-29T19:11:18.124741811Z
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/bayburt/13671
dc.publisherInstitute of Electrical and Electronics Engineers Inc.
dc.rightsinfo:eu-repo/semantics/openAccess
dc.titleIEEE Transactions on Electromagnetic Compatibility