Optimization of design parameters for heat transfer and friction factor in a heat sink with hollow trapezoidal baffles

MakaleYalnız künyeScopus SJRQ1

Özet

The aim of this study is to optimize the design parameters of a heat sink on which hollow trapezoidal baffles are mounted on the bottom surface by using Taguchi experimental-design method. The Nusselt number and the friction factor are considered as performance parameters. An orthogonal array is selected as experimental plan for the six parameters: the corner angle (α), the inclination angle (β), the baffle height (H), the baffle length (L), the baffle width (S) and Reynolds number. First of all, each goal has been optimized, separately. Then, all the goals have been optimized together, considering the priority of the goals. The length of the baffle is found to be the most influential parameter on the friction factor. This can be attributed the enhanced effect of longitudinal vortices with baffle length in flow direction. Likewise, it is demonstrated that the most effective parameter on the heat transfer is Reynolds number. The results show that the baffle width (S) and the corner angle (α) have insignificant effect on Nusselt number. The maximum heat transfer was obtained at Re = 17,000, H = 36 mm, L = 45 mm, S = 26 mm, α = 0°, β = 0°. The inclination angle (β) and the baffle height (H) have nearly no effect on the friction factor. The minimum friction factor was obtained at Re = 17,000, H = 20 mm, L = 25 mm, S = 26 mm, α = 16°, β = 0°. The inclination angle (β) and the baffle height (H) have nearly no effect on the friction factor. It can be concluded that the higher heat transfer rates can be achieved with lower pressure drop penalty with this type of vortex generator in particular configurations.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/bayburt/12556Resmi atıflarda kullanılan kalıcı adres
İndeks kayıtları
Kaydın indeks veri tabanlarındaki sayfası (aktarımda alınan kayıt numarasıyla). Erişim, indeksin kendi koşullarına bağlıdır.
Atıflar
Scopus
31
WoS
27
OpenAlex
32
Her kaynağın kendi saydığı toplam atıf; aktarım ve zenginleştirme sırasında alındı.
Tam Kayıt
AlanDeğerDil
dc.contributor.authorSahin, Bayram
dc.contributor.authorAtes, Ibrahim
dc.contributor.authorManay, Eyuphan
dc.contributor.authorBayrakceken, Abdulkadir
dc.contributor.authorCelik, Cafer
dc.date.accessioned2026-10-29T19:09:43.573896588Z
dc.date.available2026-10-29T19:09:43.573896588Z
dc.date.issued2019
dc.description.abstractThe aim of this study is to optimize the design parameters of a heat sink on which hollow trapezoidal baffles are mounted on the bottom surface by using Taguchi experimental-design method. The Nusselt number and the friction factor are considered as performance parameters. An orthogonal array is selected as experimental plan for the six parameters: the corner angle (α), the inclination angle (β), the baffle height (H), the baffle length (L), the baffle width (S) and Reynolds number. First of all, each goal has been optimized, separately. Then, all the goals have been optimized together, considering the priority of the goals. The length of the baffle is found to be the most influential parameter on the friction factor. This can be attributed the enhanced effect of longitudinal vortices with baffle length in flow direction. Likewise, it is demonstrated that the most effective parameter on the heat transfer is Reynolds number. The results show that the baffle width (S) and the corner angle (α) have insignificant effect on Nusselt number. The maximum heat transfer was obtained at Re = 17,000, H = 36 mm, L = 45 mm, S = 26 mm, α = 0°, β = 0°. The inclination angle (β) and the baffle height (H) have nearly no effect on the friction factor. The minimum friction factor was obtained at Re = 17,000, H = 20 mm, L = 25 mm, S = 26 mm, α = 16°, β = 0°. The inclination angle (β) and the baffle height (H) have nearly no effect on the friction factor. It can be concluded that the higher heat transfer rates can be achieved with lower pressure drop penalty with this type of vortex generator in particular configurations.
dc.identifier.doi10.1016/j.applthermaleng.2019.03.056
dc.identifier.eissn1873-5606
dc.identifier.endpage86
dc.identifier.issn1359-4311
dc.identifier.scopus2-s2.0-85062943569
dc.identifier.startpage76
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/bayburt/12556
dc.identifier.volume154
dc.identifier.wosWOS:000469892000008
dc.language.isoen
dc.publisherElsevier Ltd
dc.relation.ispartofApplied Thermal Engineering
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.subjectConvective heat transfer
dc.subjectHollow trapezoidal baffles
dc.subjectTaguchi method
dc.subjectTurbulent flow
dc.subject.classificationThermodynamics
dc.subject.classificationEnergy & Fuels
dc.subject.classificationEngineering, Mechanical
dc.subject.classificationMechanics
dc.subject.classificationEngineering
dc.subject.otherDesign
dc.subject.otherFriction
dc.subject.otherHeat sinks
dc.subject.otherNusselt number
dc.subject.otherReynolds number
dc.subject.otherTaguchi methods
dc.subject.otherTurbulent flow
dc.subject.otherVortex flow
dc.subject.otherConvective heat transfer
dc.subject.otherEffective parameters
dc.subject.otherHeat transfer and friction factors
dc.subject.otherHollow trapezoidal baffles
dc.subject.otherLongitudinal vortices
dc.subject.otherMaximum heat transfer
dc.subject.otherPerformance parameters
dc.subject.otherTaguchi experimental-design method
dc.subject.otherHeat convection
dc.titleOptimization of design parameters for heat transfer and friction factor in a heat sink with hollow trapezoidal baffles
dc.typeArticle
rdl.citation.openalex32
rdl.citation.scopus31
rdl.citation.wos27
rdl.oa.statusclosed
rdl.scopus.quartileQ1
rdl.source.indexSCOPUS
rdl.source.indexWOS
rdl.wos.indexScience Citation Index Expanded (SCI-EXPANDED)